Vladislav Khramenkov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vladislav Khramenkov has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alexey S. Dmitrichev
Department of Nonlinear Dynamics, Institute of Applied Physics of RAS 1 , 46 Ulyanov Str., 603950 Nizhny Novgorod, Russia
3 shared publications - Vladimir I. Nekorkin
A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences 1 , 46 Ulyanov Str., 603951 Nizhny Novgorod
2 shared publications - Aleksey S. Dmitrichev
A. V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Nizhny Novgorod, Russia
1 shared publication Federal Research Center Institute of Applied Physics of the Russian Academy of Sciences
1 shared publication- Vladimir I. Nekorkin
A. V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Nizhny Novgorod, Russia
1 shared publication Vladimir Nekorkin
1 shared publication
Latest Publications
- 30 October 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (10) , 2653-2662
Conceptual model of a three-phase generator–load system
- 30 October 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (10) , 2653-2662
Conceptual model of a three-phase generator–load system
- Open Access
- 1 October 2023
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 33 (10)
Bistability of operating modes and their switching in a three-machine power grid
We consider a power grid consisting of three synchronous generators supplying a common static load, in which one of the generators is located electrically much closer to the load than the others, due to a shorter transmission line with longitudinal inductance compensation. A reduced model is derived in the form of an ensemble with a star (hub) topology without parameter interdependence. We show that stable symmetric and asymmetric synchronous modes can be realized in the grid, which differ, in particular, in the ratio of currents through the second and third power supply paths. The modes of different types are not observed simultaneously, but the asymmetric modes always exist in pairs. A partition of the parameter space into regions with different dynamical regimes of the grid are obtained. Regions are highlighted where only synchronous operating modes can be established. It is shown that the grid can be highly multistable and, along with synchronous operating modes, have simultaneously various types of non-synchronous modes. We study non-local stability of the asymmetric synchronous modes and switchings between them under the influence one-time disturbances and additive noise fluctuations in the mechanical powers of the generators’ turbines. The characteristics of one-time disturbances are obtained leading to either return the grid back to the initial synchronous mode or switching the grid to another synchronous mode or some non-synchronous mode. The characteristics of noise fluctuations are obtained, which provide either a more probable finding of the grid in the desirable quasi-synchronous mode, or switching to an undesirable one.
- 1 October 2023
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 33 (10)
Open AccessBistability of operating modes and their switching in a three-machine power grid
We consider a power grid consisting of three synchronous generators supplying a common static load, in which one of the generators is located electrically much closer to the load than the others, due to a shorter transmission line with longitudinal inductance compensation. A reduced model is derived in the form of an ensemble with a star (hub) topology without parameter interdependence. We show that stable symmetric and asymmetric synchronous modes can be realized in the grid, which differ, in particular, in the ratio of currents through the second and third power supply paths. The modes of different types are not observed simultaneously, but the asymmetric modes always exist in pairs. A partition of the parameter space into regions with different dynamical regimes of the grid are obtained. Regions are highlighted where only synchronous operating modes can be established. It is shown that the grid can be highly multistable and, along with synchronous operating modes, have simultaneously various types of non-synchronous modes. We study non-local stability of the asymmetric synchronous modes and switchings between them under the influence one-time disturbances and additive noise fluctuations in the mechanical powers of the generators’ turbines. The characteristics of one-time disturbances are obtained leading to either return the grid back to the initial synchronous mode or switching the grid to another synchronous mode or some non-synchronous mode. The characteristics of noise fluctuations are obtained, which provide either a more probable finding of the grid in the desirable quasi-synchronous mode, or switching to an undesirable one.
- 1 November 2022
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 32 (11) , 113116
A new scenario for Braess’s paradox in power grids
We consider several topologies of power grids and analyze how the addition of transmission lines affects their dynamics. The main example we are dealing with is a power grid that has a tree-like three-element motif at the periphery. We establish conditions where the addition of a transmission line in the motif enhances its stability or induces Braess’s paradox and reduces stability of the entire grid. By using bifurcation theory and nonlocal stability analysis, we show that two scenarios for Braess’s paradox are realized in the grid. The first scenario is well described and is associated with the disappearance of the synchronous mode. The second scenario has not been previously described and is associated with the reduction of nonlocal stability of the synchronous mode due to the appearance of asynchronous modes. The necessary conditions for stable operation of the grid, under the addition of a line, are derived. It is proved that the new scenario for Braess’s paradox is realized in the grids with more complex topologies even when several lines are added in their bulks.
- 1 November 2022
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 32 (11) , 113116
A new scenario for Braess’s paradox in power grids
We consider several topologies of power grids and analyze how the addition of transmission lines affects their dynamics. The main example we are dealing with is a power grid that has a tree-like three-element motif at the periphery. We establish conditions where the addition of a transmission line in the motif enhances its stability or induces Braess’s paradox and reduces stability of the entire grid. By using bifurcation theory and nonlocal stability analysis, we show that two scenarios for Braess’s paradox are realized in the grid. The first scenario is well described and is associated with the disappearance of the synchronous mode. The second scenario has not been previously described and is associated with the reduction of nonlocal stability of the synchronous mode due to the appearance of asynchronous modes. The necessary conditions for stable operation of the grid, under the addition of a line, are derived. It is proved that the new scenario for Braess’s paradox is realized in the grids with more complex topologies even when several lines are added in their bulks.
- Open Access
- 1 August 2022
- Published by Saratov State University in Izvestiya VUZ. Applied Nonlinear Dynamics
- Vol. 30 (4) , 424-435
On the conditions for safe connection to hub-cluster power grids
- 1 August 2022
- Published by Saratov State University in Izvestiya VUZ. Applied Nonlinear Dynamics
- Vol. 30 (4) , 424-435
Open AccessOn the conditions for safe connection to hub-cluster power grids
- 1 November 2021
- Published by Elsevier in Chaos, Solitons & Fractals
- Vol. 152
Partial stability criterion for a heterogeneous power grid with hub structures
- 1 November 2021
- Published by Elsevier in Chaos, Solitons & Fractals
- Vol. 152
Partial stability criterion for a heterogeneous power grid with hub structures