Mohamed Ghorbel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed Ghorbel has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Amira Echtioui
Sfax University
4 shared publications - Wassim Zouch
King Abdulaziz University (KAU), Jeddah, Saudi Arabia
3 shared publications Ahmed Amine Daoued
Service de neurochirurgie, CHU Habib Bourghiba, Sfax, Tunisie
2 shared publicationsAhmed Ben Hamida
2 shared publications- Chokri Mhiri
Department of Neurology, Habib Bourguiba Hospital, Sfax, Tunisia
2 shared publications Chérif Ines
Service de neurochirurgie, hôpital Habib-Bourguiba, rue Al-Firdaws, Sfax, Tunisie
2 shared publications
Latest Publications
- 13 January 2026
- Published by Springer Nature in Network Modeling Analysis in Health Informatics and Bioinformatics
- Vol. 15 (1) , 39
Explainable fusion-based transfer learning for lung diseases classification
- 13 January 2026
- Published by Springer Nature in Network Modeling Analysis in Health Informatics and Bioinformatics
- Vol. 15 (1) , 39
Explainable fusion-based transfer learning for lung diseases classification
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 739-757
Bistatic 5G-NR Ambient Backscatter Communication: Propagation Study and Experimental Validation in Anechoic Chambers
Ambient Backscatter Communication (AmBC) has emerged as a promising low-power wireless communication technique, particularly for Internet of Things (IoT) applications. This paper presents an experimental study on a fifth-generation 5G New Radio (5G-NR) backscatter communication system operating at 3.5 GHz, focusing on bistatic configurations. Specific considerations are taken in the experimental setup to improve signal detection and minimize direct path interference (DPI). For this, a backscatter modulator prototype is developed and tested in controlled environments, including full anechoic (FA) and semianechoic (SA) chambers, to analyze its performance under various conditions. Moreover, a generic mathematical model has been proposed to predict the power budget of the whole AmBC system. This model takes into account geometrical parameters of the backscatter device (BD), i.e., distance and angles referring to the transmitter (Tx) and the receiver (Rx). The measurement results indicate significant variations in received backscatter power based on environmental factors such as reflections and antenna orientation. Experimental results are in good agreement with the theoretical model validating the systems feasibility and highlight the crucial impact of the sensor tag reflections, antenna orientation, and ground absorption on backscattered signal strength. The developed demonstrator consistently reflects a stable signal across different transmit power levels. This study provides key insights into the feasibility of 5G-NR ambient backscatter for energy-efficient wireless communication.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 739-757
Bistatic 5G-NR Ambient Backscatter Communication: Propagation Study and Experimental Validation in Anechoic Chambers
Ambient Backscatter Communication (AmBC) has emerged as a promising low-power wireless communication technique, particularly for Internet of Things (IoT) applications. This paper presents an experimental study on a fifth-generation 5G New Radio (5G-NR) backscatter communication system operating at 3.5 GHz, focusing on bistatic configurations. Specific considerations are taken in the experimental setup to improve signal detection and minimize direct path interference (DPI). For this, a backscatter modulator prototype is developed and tested in controlled environments, including full anechoic (FA) and semianechoic (SA) chambers, to analyze its performance under various conditions. Moreover, a generic mathematical model has been proposed to predict the power budget of the whole AmBC system. This model takes into account geometrical parameters of the backscatter device (BD), i.e., distance and angles referring to the transmitter (Tx) and the receiver (Rx). The measurement results indicate significant variations in received backscatter power based on environmental factors such as reflections and antenna orientation. Experimental results are in good agreement with the theoretical model validating the systems feasibility and highlight the crucial impact of the sensor tag reflections, antenna orientation, and ground absorption on backscattered signal strength. The developed demonstrator consistently reflects a stable signal across different transmit power levels. This study provides key insights into the feasibility of 5G-NR ambient backscatter for energy-efficient wireless communication.
- Open Access
- 3 November 2023
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (7)
Development of a Novel Hierarchically Biofabricated Blood Vessel Mimic Decorated with Three Vascular Cell Populations for the Reconstruction of Small‐Diameter Arteries
The availability of grafts to replace small‐diameter arteries remains an unmet clinical need. Here, the validated methodology is reported for a novel hybrid tissue‐engineered vascular graft that aims to match the natural structure of small‐size arteries. The blood vessel mimic (BVM) comprises an internal conduit of co‐electrospun gelatin and polycaprolactone (PCL) nanofibers (corresponding to the tunica intima of an artery), reinforced by an additional layer of PCL aligned fibers (the internal elastic membrane). Endothelial cells are deposited onto the luminal surface using a rotative bioreactor. A bioprinting system extrudes two concentric cell‐laden hydrogel layers containing respectively vascular smooth muscle cells and pericytes to create the tunica media and adventitia. The semi‐automated cellularization process reduces the production and maturation time to 6 days. After the evaluation of mechanical properties, cellular viability, hemocompatibility, and suturability, the BVM is successfully implanted in the left pulmonary artery of swine. Here, the BVM showed good hemostatic properties, capability to withstand blood pressure, and patency at 5 weeks post‐implantation. These promising data open a new avenue to developing an artery‐like product for reconstructing small‐diameter blood vessels.
- 3 November 2023
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (7)
Open AccessDevelopment of a Novel Hierarchically Biofabricated Blood Vessel Mimic Decorated with Three Vascular Cell Populations for the Reconstruction of Small‐Diameter Arteries
The availability of grafts to replace small‐diameter arteries remains an unmet clinical need. Here, the validated methodology is reported for a novel hybrid tissue‐engineered vascular graft that aims to match the natural structure of small‐size arteries. The blood vessel mimic (BVM) comprises an internal conduit of co‐electrospun gelatin and polycaprolactone (PCL) nanofibers (corresponding to the tunica intima of an artery), reinforced by an additional layer of PCL aligned fibers (the internal elastic membrane). Endothelial cells are deposited onto the luminal surface using a rotative bioreactor. A bioprinting system extrudes two concentric cell‐laden hydrogel layers containing respectively vascular smooth muscle cells and pericytes to create the tunica media and adventitia. The semi‐automated cellularization process reduces the production and maturation time to 6 days. After the evaluation of mechanical properties, cellular viability, hemocompatibility, and suturability, the BVM is successfully implanted in the left pulmonary artery of swine. Here, the BVM showed good hemostatic properties, capability to withstand blood pressure, and patency at 5 weeks post‐implantation. These promising data open a new avenue to developing an artery‐like product for reconstructing small‐diameter blood vessels.
- 13 October 2023
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 43 (3) , 1597-1626
Epileptic Seizures Detection Using iEEG Signals and Deep Learning Models
- 13 October 2023
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 43 (3) , 1597-1626
Epileptic Seizures Detection Using iEEG Signals and Deep Learning Models
- 27 March 2023
- Published by Elsevier in Revue Neurologique
- Vol. 179, S99
Le tuberculome cérébral : un challenge diagnostique
- 27 March 2023
- Published by Elsevier in Revue Neurologique
- Vol. 179, S99
Le tuberculome cérébral : un challenge diagnostique
- 27 March 2023
- Published by Elsevier in Revue Neurologique
- Vol. 179, S126
L’hémangiome veineux de la voûte crânienne : un vrai défi nosographique !
- 27 March 2023
- Published by Elsevier in Revue Neurologique
- Vol. 179, S126
L’hémangiome veineux de la voûte crânienne : un vrai défi nosographique !
- Open Access
- 25 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 9948
A Novel Convolutional Neural Network Classification Approach of Motor-Imagery EEG Recording Based on Deep Learning
Recently, Electroencephalography (EEG) motor imagery (MI) signals have received increasing attention because it became possible to use these signals to encode a person’s intention to perform an action. Researchers have used MI signals to help people with partial or total paralysis, control devices such as exoskeletons, wheelchairs, prostheses, and even independent driving. Therefore, classifying the motor imagery tasks of these signals is important for a Brain-Computer Interface (BCI) system. Classifying the MI tasks from EEG signals is difficult to offer a good decoder due to the dynamic nature of the signal, its low signal-to-noise ratio, complexity, and dependence on the sensor positions. In this paper, we investigate five multilayer methods for classifying MI tasks: proposed methods based on Artificial Neural Network, Convolutional Neural Network 1 (CNN1), CNN2, CNN1 with CNN2 merged, and the modified CNN1 with CNN2 merged. These proposed methods use different spatial and temporal characteristics extracted from raw EEG data. We demonstrate that our proposed CNN1-based method outperforms state-of-the-art machine/deep learning techniques for EEG classification by an accuracy value of 68.77% and use spatial and frequency characteristics on the BCI Competition IV-2a dataset, which includes nine subjects performing four MI tasks (left/right hand, feet, and tongue). The experimental results demonstrate the feasibility of this proposed method for the classification of MI-EEG signals and can be applied successfully to BCI systems where the amount of data is large due to daily recording.
- 25 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 9948
Open AccessA Novel Convolutional Neural Network Classification Approach of Motor-Imagery EEG Recording Based on Deep Learning
Recently, Electroencephalography (EEG) motor imagery (MI) signals have received increasing attention because it became possible to use these signals to encode a person’s intention to perform an action. Researchers have used MI signals to help people with partial or total paralysis, control devices such as exoskeletons, wheelchairs, prostheses, and even independent driving. Therefore, classifying the motor imagery tasks of these signals is important for a Brain-Computer Interface (BCI) system. Classifying the MI tasks from EEG signals is difficult to offer a good decoder due to the dynamic nature of the signal, its low signal-to-noise ratio, complexity, and dependence on the sensor positions. In this paper, we investigate five multilayer methods for classifying MI tasks: proposed methods based on Artificial Neural Network, Convolutional Neural Network 1 (CNN1), CNN2, CNN1 with CNN2 merged, and the modified CNN1 with CNN2 merged. These proposed methods use different spatial and temporal characteristics extracted from raw EEG data. We demonstrate that our proposed CNN1-based method outperforms state-of-the-art machine/deep learning techniques for EEG classification by an accuracy value of 68.77% and use spatial and frequency characteristics on the BCI Competition IV-2a dataset, which includes nine subjects performing four MI tasks (left/right hand, feet, and tongue). The experimental results demonstrate the feasibility of this proposed method for the classification of MI-EEG signals and can be applied successfully to BCI systems where the amount of data is large due to daily recording.
- Open Access
- 1 December 2020
- Published by Elsevier in SLAS Technology
- Vol. 25 (6) , 566-572
Detection Methods of COVID-19
- 1 December 2020
- Published by Elsevier in SLAS Technology
- Vol. 25 (6) , 566-572
Open AccessDetection Methods of COVID-19
- 1 March 2014
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 100 (2) , 341-352
Exploring Wavelet Transform Based Methodology for Cochlear Prosthesis Advanced Speech Processing Strategy
- 1 March 2014
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 100 (2) , 341-352
Exploring Wavelet Transform Based Methodology for Cochlear Prosthesis Advanced Speech Processing Strategy