RHRyo Hidaka

Ryo Hidaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ryo Hidaka has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and accuracy of an artificial intelligence model for predicting the progression of hip osteoarthritis using plain radiographs and clinical data: a retrospective study

    by Ryo Hidaka, Kenta Matsuda, Takashi Igari, Shu Takeuchi, Yuichi Imoto, Satoshi Yagi, Hirotaka Kawano

    Predicting the progression of hip osteoarthritis (OA) remains challenging, and no reliable predictive method has been established. This study aimed to develop an artificial intelligence (AI) model to predict hip OA progression via plain radiographs and patient data and to determine its accuracy. This retrospective study utilized anteroposterior pelvic radiographs of consecutive patients with hip OA who underwent primary unilateral total hip arthroplasty. Radiographs diagnosed with Kellgren–Lawrence (KL) grade 0–2 were extracted from 361 patients and 1697 images. This AI model was developed to predict whether OA would progress from KL grade 0–2 to KL grade ≥ 3 within n years (n = 3, 4, 5). A gradient-boosting decision tree approach was utilized according to feature extractions obtained by a convolutional neural network from radiographs and patient data (height, body weight, sex, age, and KL grade given by an orthopedic surgeon) with five-fold cross-validation. The model performance was assessed using accuracy, specificity, sensitivity, and the area under the receiver operating characteristic curve (AUC). The mean accuracy, specificity, sensitivity, and AUC of our prediction model were, respectively, 81.8%, 88.0%, 66.7%, and 0.836 for 3 years; 79.8%, 85.0%, 71.6%, and 0.836 for 4 years; and 78.5%, 80.4%, 76.9%, and 0.846 for 5 years. The proposed AI model performed adequately in predicting hip OA progression and may be clinically applicable with additional datasets and validation.


  • Open Access

    Initial stability of cementless acetabular cups using robotic‐assisted total hip arthroplasty compared with the conventional manual technique: An in vitro biomechanical study

    by Ryo Hidaka, Kenta Matsuda, Hidetaka Mochizuki, Hirotaka Kawano

    Background: The aim of this study is to determine whether the initial stability of a cementless cup with the Mako system is superior to that of a conventional manual technique using bone models.Methods: The bone models were prepared using a polyurethane foam block. Two hemispherical cementless cups (highly porous titanium cup [Trident II Tritanium, Stryker] and hydroxyapatite‐coated titanium cup [Trident HA, Stryker]) were implanted using the Mako system. The torque of the cups was measured by rotational and lever‐out torque testing and compared with that of a conventional manual technique.Results: The two types of cups that were implanted using the Mako system demonstrated significantly higher mean rotational torque than that of the manual technique (p < 0.01, p = 0.01, respectively).Conclusions: This study provides the advantage of the initial stability of a cementless hemispherical cup implanted by the Mako system compared with that of the conventional manual technique.


  • Open Access

    Kinesiophobia is associated with quality of life after total hip arthroplasty: A short-term prospective observational study

    by Ryo Hidaka, Takeyuki Tanaka, Kazuaki Hashikura, Hiroyuki Oka, Ko Matsudaira, Kenta Matsuda, Toru Moro, Hirotaka Kawano, Sakae Tanaka

    Background: Kinesiophobia and pain catastrophizing are key factors that affect outcomes after total knee arthroplasty. However, its impact on outcomes after total hip arthroplasty (THA) remains unclear. This study aimed to determine whether kinesiophobia, assessed by the Tampa Scale for Kinesiophobia (TSK)-11, and pain catastrophizing, assessed by the Pain Catastrophizing Scale (PCS), were associated with quality of life (QOL) at 12 months after THA. Methods: Ninety consecutively patients were evaluated prospectively at 12 months after THA. QOL scores were assessed by disease-specific QOL (the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire) and general QOL (the EuroQOL-5 Dimensions), pain intensity was used by Visual Analog Scale, and TSK-11 and PCS were evaluated pre-operative and at 12 months after THA. Each QOL score at 12 months was used for multivariate analysis. Results: Pain intensity and TSK-11 were independently correlated with the disease-specific and general QOL at 12 months after THA in the multiple regression analysis. PCS was not correlated with each QOL at 12 months after THA. Conclusions: Kinesiophobia and pain intensity were independently associated with disease-specific and general QOL at 12 months after THA. Higher kinesiophobia and pain intensity were potential factors that lower QOL at 12 months after THA.

  • Open Access

    Association of high kinesiophobia and pain catastrophizing with quality of life in severe hip osteoarthritis: a cross-sectional study

    by Ryo Hidaka, Takeyuki Tanaka, Kazuaki Hashikura, Hiroyuki Oka, Ko Matsudaira, Toru Moro, Kenta Matsuda, Hirotaka Kawano, Sakae Tanaka

    Background: While fear of movement is an important predictor of pain and disability in osteoarthritis (OA), its impact on patients with hip OA remains uncertain. This study aimed to determine whether fear of movement, evaluated by the Tampa Scale for Kinesiophobia (TSK)-11, and pain catastrophizing, evaluated by the Pain Catastrophizing Scale (PCS), were associated with quality of life (QOL) in patients with hip OA. Methods: This cross-sectional study was conducted between November 2017 and December 2018. Ninety-one consecutively enrolled patients with severe hip OA were scheduled for primary unilateral total hip arthroplasty. The EuroQOL-5 Dimensions questionnaire was used to measure general QOL. The Japanese Orthopedic Association Hip Disease Evaluation Questionnaire was used to assess disease-specific QOL. The covariates included age, sex, body mass index (BMI), pain intensity, high pain catastrophizing (PCS ≥ 30), and high kinesiophobia (TSK-11 ≥ 25). Variables were subjected to multivariate analysis using each QOL scale. Results: In multiple regression analysis, pain intensity, high pain catastrophizing, and BMI were independently correlated with the disease-specific QOL scale. High pain catastrophizing, pain intensity, and high kinesiophobia were independently correlated with the general QOL scale. Conclusions: High pain catastrophizing (PCS ≥ 30) was independently associated with disease and general QOL scales. High kinesiophobia (TSK-11 ≥ 25) was independently associated with the general QOL scale in preoperative patients with severe hip OA.


  • Open Access

    Association of high kinesiophobia and pain catastrophizing with quality of life in severe hip osteoarthritis

    by Ryo Hidaka, Takeyuki Tanaka, Kazuaki Hashikura, Hiroyuki Oka, Kou Matsudaira, Toru Moro, Hirotaka Kawano, Sakae Tanaka

    Background: While fear of movement is an important predictor of pain and disability in osteoarthritis (OA), its impact on patients with hip OA remains uncertain. This study aimed to determine whether fear of movement, evaluated by the Tampa Scale for Kinesiophobia (TSK)-11, and pain catastrophizing, evaluated by the Pain Catastrophizing Scale (PCS), were associated with quality of life (QOL) in patients with hip OA. Methods: This cross-sectional study was conducted between Nov 2017 and Dec 2018. Ninety-one consecutively enrolled patients with severe hip OA were scheduled for primary unilateral total hip arthroplasty. The EuroQOL-5 Dimensions questionnaire was used to measure general QOL. The Japanese Orthopedic Association Hip Disease Evaluation Questionnaire was used to assess disease-specific QOL. The covariates included age, sex, body mass index (BMI), pain intensity, high pain catastrophizing (PCS ≥ 30), and high kinesiophobia (TSK-11 ≥ 25). Variables were subjected to multivariate analysis using each QOL scale. Results: In multiple regression analysis, pain intensity, high pain catastrophizing, and BMI were independently correlated with the disease-specific QOL scale. High pain catastrophizing, pain intensity, and high kinesiophobia were independently correlated with the general QOL scale. Conclusions: High pain catastrophizing (PCS ≥ 30) was independently associated with disease and general QOL scales. High kinesiophobia (TSK-11 ≥ 25) was independently associated with the general QOL scale in preoperative patients with severe hip OA.

  • Open Access

    Clinical effects of combined anteversion and offset on postoperative dislocation in total hip arthroplasty

    by Kenta Matsuda, Ryo Hidaka, Shigeru Nakamura, Masaki Nakamura, Hirotaka Kawano

    Background Implant impingement and soft tissue tension are factors involved in dislocation after total hip arthroplasty (THA). Combined anteversion (CA) has been used as an indicator for implant placement; however, placing implants optimally remains challenging. Moreover, the effect of changes in offset on dislocation remains unclear. We aimed to clarify the effects of postoperative CA and pre- and postoperative changes in offset on dislocation. Methods We included patients who underwent primary cementless THA performed between 2013 and 2020. The mean values of CA and offset in the dislocation and non-dislocation groups were compared. The CA values within ± 10% of the recommended values were defined as good CA, and those outside the range were defined as poor CA. The dislocation rates in the good and poor CA groups and in the groups with and without increased offset were compared. Results A total of 283 hips were included. The mean values of CA in the dislocation and non-dislocation groups were significantly different (p < 0.001). The dislocation rate was significantly lower in the good CA group (p < 0.05). The dislocation rates in the groups with and without increased total offset were 0.5% and 4.3%, respectively (p = 0.004). There were no dislocations in patients with good CA and increased offset. Conclusions The dislocation rate was significantly lower when implants were placed within ± 10% of the recommended CA value. Our results suggest that dislocation can be avoided by placing the implant in the good CA range and considering the increase in total offset on the operative side.

  • Open Access

    Optimal combined anteversion range for obtaining a wider range of motion without prosthetic impingement after total hip arthroplasty: a three-dimensional analysis study

    by Ryo Hidaka, Kenta Matsuda, Masaki Nakamura, Shigeru Nakamura, Hirotaka Kawano

    Background: Obtaining a larger theoretical range of motion (ROM) is crucial to avoid prosthetic impingement after total hip arthroplasty (THA); however, no reports have examined the permissible range values of combined anteversion (CA) satisfying targeted ROM without prosthetic impingement. This retrospective study aimed to evaluate the possible postoperative CA extent that would allow meeting target ROM criteria according to Yoshimine’s theory using computed tomography (CT)-based three-dimensional motion analysis after THA. Methods: This study included 114 patients (133 hips) who underwent cementless primary THA using a CT-based navigation system and implants (oscillation angle ≥ 135°). Implant positions were determined using Yoshimine's CA formula. Postoperative evaluation was conducted using a three-dimensional templating software for CT data. The postoperative Yoshimine’s and Widmer’s CA was calculated, and the difference between the target and postoperative values was defined as the error of Yoshimine’s CA and Widmer’s CA. Prosthetic ROM was assessed by Yoshimine’s stringent criteria for activities of daily living. Based on fulfilling these criteria, all patients were divided into the ROM (+) and ROM (−) groups. Evaluation items were compared between the two groups. Results: There were 111 and 22 hips in the ROM (+) and ROM (−) groups, respectively. A significant difference was noted in the absolute error of Yoshimine’s and Widmer’s CA between the two groups. Using receiver operating characteristic analysis, threshold values of 6.0 (higher values indicate greater disability; sensitivity 90.9%, specificity 72.1%) for the absolute Yoshimine’s CA difference (area under the curve [AUC] 0.87, P < 0.01) and 6.9 (higher values indicate greater disability; sensitivity 68.2%, specificity 88.3%) for the absolute Widmer’s CA difference (AUC 0.83, P < 0.01) were predictors in the ROM (−) group. Conclusions: The target range of Yoshimine’s CA (90.8° ± 6.0°) and Widmer’s CA values (37.3° ± 6.9°) was crucial in implant orientation for obtaining theoretical ROM without prosthetic impingement after THA.


  • Open Access

    Optimal Combined Anteversion Range for Obtaining a Wider Range of Motion without Prosthetic Impingement after Total Hip Arthroplasty: A Three-dimensional Analysis Study

    by Ryo Hidaka, Kenta Matsuda, Masaki Nakamura, Shigeru Nakamura, Hirotaka Kawano

    Background: Obtaining a larger theoretical range of motion (ROM) is crucial to avoid prosthetic impingement after total hip arthroplasty (THA); however, no reports have examined the permissible range values of combined anteversion (CA) satisfying targeted ROM without prosthetic impingement. This retrospective study aimed to evaluate the possible postoperative CA extent that would allow meeting target ROM criteria according to Yoshimine’s theory using computed tomography (CT)-based three-dimensional motion analysis after THA.Methods: This study included 114 patients (133 hips) who underwent cementless primary THA using a CT-based navigation system and implants (oscillation angle ≥135°). Implant positions were determined using Yoshimine's CA formula. Postoperative evaluation was conducted using a three-dimensional templating software for CT data. The postoperative Yoshimine’s and Widmer’s CA was calculated, and the difference between the target and postoperative values was defined as the error of Yoshimine’s CA and Widmer’s CA. Prosthetic ROM was assessed by Yoshimine’s stringent criteria for activities of daily living. Based on fulfilling these criteria, all patients were divided into the ROM (+) and ROM (-) groups. Evaluation items were compared between the two groups.Results: There were 111 and 22 hips in the ROM (+) and ROM (-) groups, respectively. A significant difference was noted in the absolute error of Yoshimine’s and Widmer’s CA between the two groups. Using receiver operating characteristic analysis, threshold values of 6.0 (higher values indicate greater disability; sensitivity 90.9%, specificity 72.1%) for the absolute Yoshimine’s CA difference (area under the curve [AUC] 0.87, PPConclusions: The target range of Yoshimine’s CA (90.8°±6.0°) and Widmer’s CA values (37.3°±6.9°) was crucial in implant orientation for obtaining theoretical ROM without prosthetic impingement after THA.

  • Open Access

    Optimal combined anteversion pattern for obtaining a wider range of motion without prosthetic impingement after total hip arthroplasty: a three-dimensional analysis study

    by Ryo Hidaka, Kenta Matsuda, Masaki Nakamura, Shigeru Nakamura, Hirotaka Kawano

    Background Obtaining a larger theoretical range of motion (ROM) is crucial to avoid prosthetic impingement after total hip arthroplasty (THA); however, no reports have examined the permissible range values of combined anteversion (CA) satisfying targeted ROM without prosthetic impingement. This retrospective study aimed to evaluate the possible postoperative CA extent that would allow meeting target ROM criteria according to Yoshimine’s theory using computed tomography (CT)-based three-dimensional motion analysis after THA. Methods This study included 114 patients (133 hips) who underwent cementless primary THA using a CT-based navigation system and implants (oscillation angle ≥ 135°). Implant positions were determined using Yoshimine's CA formula. Postoperative evaluation was conducted using a three-dimensional templating software for CT data. The postoperative Yoshimine’s and Widmer’s CA was calculated, and the difference between the target and postoperative values was defined as the error of Yoshimine’s CA and Widmer’s CA. Prosthetic ROM was assessed by Yoshimine’s stringent criteria for activities of daily living. Based on fulfilling these criteria, all patients were divided into the ROM (+) and ROM (-) groups. Evaluation items were compared between the two groups. Results There were 111 and 22 hips in the ROM (+) and ROM (-) groups, respectively. A significant difference was noted in the absolute error of Yoshimine’s and Widmer’s CA between the two groups. Using receiver operating characteristic analysis, threshold values of 6.0 (higher values indicate greater disability; sensitivity 90.9%, specificity 72.1%) for the absolute Yoshimine’s CA difference (area under the curve [AUC] 0.87, P < 0.01) and 6.9 (higher values indicate greater disability; sensitivity 68.2%, specificity 88.3%) for the absolute Widmer’s CA difference (AUC 0.83, P < 0.01) were predictors in the ROM (-) group. Conclusions The target range of Yoshimine’s CA (90.8°±6.0°) and Widmer’s CA values (37.3°±6.9°) was crucial in implant orientation for obtaining theoretical ROM without prosthetic impingement after THA.

  • Open Access

    Rapid Destruction of the Hip Joint After Acetabular Fracture in an Elderly Patient

    by Ryo Hidaka, Kenta Matsuda, Hirotaka Kawano