MDManasi Doshi

Manasi Doshi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manasi Doshi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Controlled Release Tests Results for the Methane Lidar Camera

    by Manasi Doshi, Tetsushi Yamada, Scott Quinn, Gokhan Erol, Christopher Boucher, Michael Kenison, Andrew Pomerantz

    Methane emissions detection using continuous monitors enables round-the-clock monitoring to quickly identify emissions from oil and gas facilities. The SLB methane lidar camera participated in Stanford University’s 2024 Methane Controlled Release Campaign to characterize its performance at detecting, localizing, and quantifying methane emissions from different sources. The camera successfully detected and localized emissions as low as 0.3 kg/h as well as super emitters as high as 310 kg/h. The camera detected all but one emission greater than 1 kg/h, resulting in a limit of detection at 90% confidence of 1.5 kg/h. In addition, the camera localized all emissions to the correct piece of equipment or to the adjacent piece of equipment, including many releases where the camera’s vantage point was suboptimal. The emission rates measured by the camera showed a systematic underestimation compared to the ground truth results. Such an underestimation is unexpected and inconsistent with the camera’s performance in previous studies. In this paper, we perform a root cause analysis to identify the cause of the underestimation. The analysis concludes that the measured methane signal was accurate and that the underestimation was caused by a wind shadow that resulted in the camera’s anemometer systematically underestimating the wind speed. Reprocessing the methane lidar camera’s data using an on-facility anemometer not affected by a wind shadow instead of the camera’s anemometer resulted in quantification that was within a factor of two 78% of the time and a systematic bias of 11%. The 90% limit of detection, the fraction of results within a factor of two, and the systematic bias (using the on-facility anemometer), are superior to any scanning/imaging system at METEC 2023 and 2024 ADED programs. As a result of this study, improvements in the camera installation workflow have been introduced to avoid wind shadows in the future.


  • Substrate Effects on the Transient Chemiresistive Gas Sensing Performance of Monolayer Graphene

    by Jie Zhang, Manasi Doshi, Eric P. Fahrenthold

    Chemiresistive oxygen sensing experiments on graphene have shown a wide range of sheet conductivities, with mean values that depend on the sensor substrate, and an order of magnitude variation between reported values for experiments conducted with the same substrate. Recent research by the authors has performed a new series of experiments investigating substrate effects on chemiresistive oxygen sensing with monolayer graphene. The testing included four different substrates, ranging from that most commonly used (silicon dioxide over silicon) to one almost never used (hBN over silicon). The experiments employed eddy current testing, eliminating variations in contact resistance included in the published data base, and a single graphene supplier, eliminating variations in graphene quality included in the published data base. The results show a strong dependence of the measured sheet conductance on the graphene substrate, including (in the most pronounced case) a sign reversal of the change in conductance induced by oxygen adsorption. This observed substrate dependence may be exploited, by introducing sensor arrays composed of monolayer graphene deposited on different types of substrates, in order to add selectivity to chemiresitive gas sensors.

  • Eddy Current Measurement of Chemiresistive Sensing Transients in Graphene-hBN Heterostructures

    by Manasi Doshi, Jie Zhang, Eric P. Fahrenthold

    The development of graphene-based electronic and gas sensing devices has motivated considerable research interest in the properties of graphene-hBN heterostructures. Eddy current measurements of the sheet conductance of graphene-hBN heterostructures show a relatively low conductance, as compared to results previously reported in the literature, all of which were obtained using contact-based measurement methods. Chemiresis-tive measurements of the graphene-hBN heterostructure response to oxygen adsorption, including hysteric effects under transient multicycle loading, show that the incremental sheet conductance responses of graphene and graphene-hBN sensors differ in sign. A transient, nonlinear, history dependent constitutive model of graphene-hBN response to oxygen adsorption distinguishes stochastic variations in material properties from deterministic variations in sensor performance. The deterministic variations are due to sensing process hysteresis, a phenomenon of central interest in the development of graphene-based sensor systems.


  • Open Access

    Explosive molecule sensing at lattice defect sites in metallic carbon nanotubes

    by Manasi Doshi, Eric P. Fahrenthold

    Explosives and hazardous gas sensing using carbon nanotube (CNT) based sensors has been a focus of considerable experimental research. The simplest sensors have employed a chemiresistive sensing mechanism, and rely on substitutional doping or structural flaws (vacancy, divacancy, or Stone–Wales defects) to increase sensitivity. However since chemiresistive sensors often show poor selectivity, further improvements are needed. Ab initio analysis of the chemiresistive response of five metallic CNT sensors incorporating substitutional doping or structural flaws suggests that arrays of these devices may be effectively employed to improve selectivity. In particular, arrays composed of doped or flawed CNTs can distinguish nitroaromatic and nitramine explosive molecules from each other and from four common background gases. Array selectivity is improved by capitalizing upon the nonlinear current–voltage characteristics of the substitutionally doped or structurally flawed CNTs.