Lisa K. Seiler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lisa K. Seiler has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Cornelia Blume
Institute of Technical Chemistry, Leibniz University Hannover, Hannover, Germany
2 shared publications Patrick Lindner
Institute of Technical Chemistry, Leibniz University Hannover, Hannover, Germany
2 shared publications- Christian Erck
Helmholtz Centre for Infection Research, Cellular Proteome Research Group, 38124 Braunschweig, Germany
1 shared publication Christine S. Falk
Institute for Transplant Immunology, Hannover Medical School, Carl-Neuberg-Strasse 1, 30625 Hannover, Germany
1 shared publication- Christine Susanne Falk
Institute of Transplant Immunology, Hannover Medical School, Hannover, Germany
1 shared publication - Christoph Nikolin
Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, 30625 Hannover, Germany
1 shared publication
Latest Publications
- Open Access
- 27 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 26959
Lateral Flow Assay to detect CXCL10 as a diagnose-supporting biomarker for Polyomavirus-associated Nephropathy (PVAN) after kidney transplantation (KTx)
Kidney grafts, as the most transplanted organs, require intensive monitoring to ensure optimal transplant survival rates for patients. These rates can be jeopardized by severe, difficult-to-treat opportunistic infections such as polyomavirus, which can lead to polyomavirus-associated nephropathy (PVAN). There is an urgent need for non-invasive biomarker tests to narrow down the number of patients who require a transplant biopsy to confirm PVAN. The chemokine CXCL10 was significantly elevated in urine samples from kidney transplant recipients (KTR) with biopsy-confirmed PVAN compared to KTRs with a protocol biopsy found to be normal (114.8 ± 177.3 pg/ml, n = 22 vs. 11.4 ± 22.3 pg/ml, p < 0.0001, n = 45). Therefore, we developed a lateral flow assay (LFA) for the detection of PVAN with an area under the curve (AUC) of 0.832 according to receiver operating characteristic analysis as a point-of-care test.
- 27 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 26959
Open AccessLateral Flow Assay to detect CXCL10 as a diagnose-supporting biomarker for Polyomavirus-associated Nephropathy (PVAN) after kidney transplantation (KTx)
Kidney grafts, as the most transplanted organs, require intensive monitoring to ensure optimal transplant survival rates for patients. These rates can be jeopardized by severe, difficult-to-treat opportunistic infections such as polyomavirus, which can lead to polyomavirus-associated nephropathy (PVAN). There is an urgent need for non-invasive biomarker tests to narrow down the number of patients who require a transplant biopsy to confirm PVAN. The chemokine CXCL10 was significantly elevated in urine samples from kidney transplant recipients (KTR) with biopsy-confirmed PVAN compared to KTRs with a protocol biopsy found to be normal (114.8 ± 177.3 pg/ml, n = 22 vs. 11.4 ± 22.3 pg/ml, p < 0.0001, n = 45). Therefore, we developed a lateral flow assay (LFA) for the detection of PVAN with an area under the curve (AUC) of 0.832 according to receiver operating characteristic analysis as a point-of-care test.
- Open Access
- 25 January 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 308
An Antibody-Aptamer-Hybrid Lateral Flow Assay for Detection of CXCL9 in Antibody-Mediated Rejection after Kidney Transplantation
Chronic antibody-mediated rejection (AMR) is a key limiting factor for the clinical outcome of a kidney transplantation (Ktx), where early diagnosis and therapeutic intervention is needed. This study describes the identification of the biomarker CXC-motif chemokine ligand (CXCL) 9 as an indicator for AMR and presents a new aptamer-antibody-hybrid lateral flow assay (hybrid-LFA) for detection in urine. Biomarker evaluation included two independent cohorts of kidney transplant recipients (KTRs) from a protocol biopsy program and used subgroup comparisons according to BANFF-classifications. Plasma, urine and biopsy lysate samples were analyzed with a Luminex-based multiplex assay. The CXCL9-specific hybrid-LFA was developed based upon a specific rat antibody immobilized on a nitrocellulose-membrane and the coupling of a CXCL9-binding aptamer to gold nanoparticles. LFA performance was assessed according to receiver operating characteristic (ROC) analysis. Among 15 high-scored biomarkers according to a neural network analysis, significantly higher levels of CXCL9 were found in plasma and urine and biopsy lysates of KTRs with biopsy-proven AMR. The newly developed hybrid-LFA reached a sensitivity and specificity of 71% and an AUC of 0.79 for CXCL9. This point-of-care-test (POCT) improves early diagnosis-making in AMR after Ktx, especially in KTRs with undetermined status of donor-specific HLA-antibodies.
- 25 January 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 308
Open AccessAn Antibody-Aptamer-Hybrid Lateral Flow Assay for Detection of CXCL9 in Antibody-Mediated Rejection after Kidney Transplantation
Chronic antibody-mediated rejection (AMR) is a key limiting factor for the clinical outcome of a kidney transplantation (Ktx), where early diagnosis and therapeutic intervention is needed. This study describes the identification of the biomarker CXC-motif chemokine ligand (CXCL) 9 as an indicator for AMR and presents a new aptamer-antibody-hybrid lateral flow assay (hybrid-LFA) for detection in urine. Biomarker evaluation included two independent cohorts of kidney transplant recipients (KTRs) from a protocol biopsy program and used subgroup comparisons according to BANFF-classifications. Plasma, urine and biopsy lysate samples were analyzed with a Luminex-based multiplex assay. The CXCL9-specific hybrid-LFA was developed based upon a specific rat antibody immobilized on a nitrocellulose-membrane and the coupling of a CXCL9-binding aptamer to gold nanoparticles. LFA performance was assessed according to receiver operating characteristic (ROC) analysis. Among 15 high-scored biomarkers according to a neural network analysis, significantly higher levels of CXCL9 were found in plasma and urine and biopsy lysates of KTRs with biopsy-proven AMR. The newly developed hybrid-LFA reached a sensitivity and specificity of 71% and an AUC of 0.79 for CXCL9. This point-of-care-test (POCT) improves early diagnosis-making in AMR after Ktx, especially in KTRs with undetermined status of donor-specific HLA-antibodies.
- Open Access
- 2 August 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (17) , 5369-5379
A new lateral flow assay to detect sIL-2R during T-cell mediated rejection after kidney transplantation
Kidney is the most frequently transplanted among all solid organs worldwide. Kidney transplant recipients (KTRs) undergo regular follow-up examinations for the early detection of acute rejections. The gold standard for proving a T-cell mediated rejection (TCMR) is a biopsy of the renal graft often occurring as indication biopsy, in parallel to an increased serum creatinine that may indicate deterioration of renal transplant function. The goal of the current work was to establish a lateral flow assay (LFA) for diagnosing acute TCMR to avoid harmful, invasive biopsies. Soluble interleukin-2 (IL-2) receptor (sIl-2R) is a potential biomarker representing the α-subunit of the IL-2 receptor produced by activated T-cells, e.g., after allogen contact. To explore the diagnostic potential of sIL-2R as a biomarker for TCMR and borderline TCMR, plasma and urine samples were collected from three independent KTR cohorts with various distinct histopathological diagnostic findings according to BANFF (containing 112 rsp. 71 rsp. 61 KTRs). Samples were analyzed by a Luminex-based multiplex technique and cut off-ranges were determined. An LFA was established with two specific sIL-2R-antibodies immobilized on a nitrocellulose membrane. A significant association between TCMR, borderline TCMR and sIL-2R in plasma and between TCMR and sIL-2R in urine of KTRs was confirmed using the Mann–Whitney U test. The LFA was tested with sIL-2R-spiked buffer samples establishing a detection limit of 25 pM. The performance of the new LFA was confirmed by analyzing urine samples of the 2nd and 3rd patient cohort with 35 KTRs with biopsy proven TCMRs, 3 KTRs diagnosed with borderline TCMR, 1 mixed AMR/TCMR rsp. AMR/borderline TCMR and 13 control patients with a rejection-free kidney graft proven by protocol biopsies. The new point-of-care assay showed a specificity of 84.6% and sensitivity of 87.5%, and a superior estimated glomerular filtration rate (eGFR) at the time point of biopsy (specificity 30.8%, sensitivity 85%).
- 2 August 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (17) , 5369-5379
Open AccessA new lateral flow assay to detect sIL-2R during T-cell mediated rejection after kidney transplantation
Kidney is the most frequently transplanted among all solid organs worldwide. Kidney transplant recipients (KTRs) undergo regular follow-up examinations for the early detection of acute rejections. The gold standard for proving a T-cell mediated rejection (TCMR) is a biopsy of the renal graft often occurring as indication biopsy, in parallel to an increased serum creatinine that may indicate deterioration of renal transplant function. The goal of the current work was to establish a lateral flow assay (LFA) for diagnosing acute TCMR to avoid harmful, invasive biopsies. Soluble interleukin-2 (IL-2) receptor (sIl-2R) is a potential biomarker representing the α-subunit of the IL-2 receptor produced by activated T-cells, e.g., after allogen contact. To explore the diagnostic potential of sIL-2R as a biomarker for TCMR and borderline TCMR, plasma and urine samples were collected from three independent KTR cohorts with various distinct histopathological diagnostic findings according to BANFF (containing 112 rsp. 71 rsp. 61 KTRs). Samples were analyzed by a Luminex-based multiplex technique and cut off-ranges were determined. An LFA was established with two specific sIL-2R-antibodies immobilized on a nitrocellulose membrane. A significant association between TCMR, borderline TCMR and sIL-2R in plasma and between TCMR and sIL-2R in urine of KTRs was confirmed using the Mann–Whitney U test. The LFA was tested with sIL-2R-spiked buffer samples establishing a detection limit of 25 pM. The performance of the new LFA was confirmed by analyzing urine samples of the 2nd and 3rd patient cohort with 35 KTRs with biopsy proven TCMRs, 3 KTRs diagnosed with borderline TCMR, 1 mixed AMR/TCMR rsp. AMR/borderline TCMR and 13 control patients with a rejection-free kidney graft proven by protocol biopsies. The new point-of-care assay showed a specificity of 84.6% and sensitivity of 87.5%, and a superior estimated glomerular filtration rate (eGFR) at the time point of biopsy (specificity 30.8%, sensitivity 85%).