CPChristos Patriotis

Christos Patriotis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christos Patriotis has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance of multiple multi-cancer detection tests using a large independent reference set (Alliance A212102)

    by Marie E Wood, Paul F Pinsky, Paul J Novotny, Elyse Leevan, Matthias Weiss, Dan C Edelman, Mark Watson, Christos Patriotis, Jason D Merker, Philip C Prorok, et al.

    Background: Reference sets are needed to evaluate performance of multi-cancer detection (MCD) assays. The National Cancer Institute funded the Alliance reference set study to assess MCDs for use in future trials. Methods: Individuals with cancer and controls were recruited; blood specimens were collected prior to cancer treatment. A performance evaluation study was designed utilizing reference set samples. Companies (n = 6) were selected to participate based on review of performance data and ability to utilize the blood collection tube. Companies received samples from cancer types their assay was designed to detect (“targeted”), plus additional “non-targeted” and control samples. Companies reported positive/negative calls, risk scores, and tissue-of-origin (TOO) predictions. Sensitivity was computed for early (I-II) and late (III-IV) stage cases, based on positive/negative calls (SEPN) and at fixed 98% specificity (SE98). Specificity and TOO accuracy were computed. Results: Five hundred and forty nine cases (encompassing 13 cancer types) and 413 controls from the reference set were included in the study. Companies assessed samples from median 6 (range 5-9) targeted cancer types and median 8 (range: 7-11) overall cancer types. Median (range) specificity was 92.3% (76.5%-98.5%). Median (range) SEPN was 32% (25%-42%) for early stage and 73% (48%-89%) for late stage; while median (range) SE98 was 19% (8%-35%) for early stage and 66% (13%-79%) for late stage. Median sensitivity for non-targeted types was 40% (early stage) and 52% (late stage). Median (range) TOO accuracy (primary predicted site) was 75% (64%-78%). Conclusions: Sensitivity and specificity varied widely across assays with early-stage sensitivity substantially lower than late-stage sensitivity. Clinical Trial Registration Number: ClinicalTrials.gov identifier NCT05334069.


  • Open Access

    Framework to Select Multi-Cancer Detection Assays in the National Cancer Institute’s Vanguard Study

    by Elyse LeeVan, Amanda L. Skarlupka, Christos Patriotis, Wendy S. Rubinstein, Paul F. Pinsky, Wade Bolton, Anthony Dickherber, Daniel C. Edelman, Lyndsay N. Harris, Hormuzd A. Katki, et al.

    Background: The Cancer Screening Research Network is a new clinical trials network funded by the NCI. The first Cancer Screening Research Network study, the Vanguard Study (VS), will assess the feasibility of using multi-cancer detection (MCD) tests in future randomized controlled trials. Methods: This article describes the framework NCI developed to engage MCD assay developers, evaluate emerging technologies using biobank reference sets, and select fit-for-purpose MCD assays for inclusion in the VS. Results: NCI evaluated 23 technologically diverse MCD assays, all utilizing machine learning and artificial intelligence components. Nine assays underwent blinded performance evaluations using specimens from three biobanks. Assay developers were provided with independent assessments of their assays, which enabled them to make further assay refinements to enhance performance. The assay selection process resulted in participation by two assay companies in the VS. Conclusions: NCI created a fair and transparent process to streamline the evaluation of assay performance and to select promising assays for clinical research and public health initiatives. Impact: Significant resources are required for large-scale cancer screening trials; therefore, promising technologies must be prioritized for inclusion in a definitive trial. NCI’s assay selection framework can be used and repurposed by other networks and institutions.


  • Top Cited Papers
    Open Access

    Cancer screening with multicancer detection tests: A translational science review

    by Wendy S. Rubinstein, Christos Patriotis, Anthony Dickherber, Paul K. J. Han, Hormuzd A. Katki, Elyse LeeVan, Paul F. Pinsky, Philip C. Prorok, Amanda L. Skarlupka, Sarah M. Temkin, et al.

    Multicancer detection (MCD) tests use a single, easily obtainable biospecimen, such as blood, to screen for more than one cancer concurrently. MCD tests can potentially be used to improve early cancer detection, including cancers that currently lack effective screening methods. However, these tests have unknown and unquantified benefits and harms. MCD tests differ from conventional cancer screening tests in that the organ responsible for a positive test is unknown, and a broad diagnostic workup may be necessary to confirm the location and type of underlying cancer. Among two prospective studies involving greater than 16,000 individuals, MCD tests identified those who had some cancers without currently recommended screening tests, including pancreas, ovary, liver, uterus, small intestine, oropharyngeal, bone, thyroid, and hematologic malignancies, at early stages. Reported MCD test sensitivities range from 27% to 95% but differ by organ and are lower for early stage cancers, for which treatment toxicity would be lowest and the potential for cure might be highest. False reassurance from a negative MCD result may reduce screening adherence, risking a loss in proven public health benefits from standard‐of‐care screening. Prospective clinical trials are needed to address uncertainties about MCD accuracy to detect different cancers in asymptomatic individuals, whether these tests can detect cancer sufficiently early for effective treatment and mortality reduction, the degree to which these tests may contribute to cancer overdiagnosis and overtreatment, whether MCD tests work equally well across all populations, and the appropriate diagnostic evaluation and follow‐up for patients with a positive test.


  • Open Access

    Revisiting the standard blueprint for biomarker development to address emerging cancer early detection technologies

    by Ruth Etzioni, Roman Gulati, Christos Patriotis, Carolyn Rutter, Yingye Zheng, Sudhir Srivastava, Ziding Feng

    Novel liquid biopsy technologies are creating a watershed moment in cancer early detection. Evidence supporting population screening is nascent, but a rush to market the new tests is prompting cancer early detection researchers to revisit the standard blueprint that the Early Detection Research Network established to evaluate novel screening biomarkers. In this commentary, we review the Early Detection Research Network’s Phases of Biomarker Development (PBD) for rigorous evaluation of novel early detection biomarkers and discuss both hazards and opportunities involved in expedited evaluation. According to the PBD, for a biomarker-based test to be considered for population screening, 1) test sensitivity in a prospective screening setting must be adequate, 2) the shift to early curable stages must be meaningful, and 3) any stage shift must translate into clinically significant mortality benefit. In the past, determining mortality benefit has required lengthy randomized screening trials, but interest is growing in expedited trial designs with shorter-term endpoints. Whether and how best to use such endpoints in a manner that retains the rigor of the PBD remains to be determined. We discuss how computational disease modeling can be harnessed to learn about screening impact and meet the needs of the moment.


  • Open Access

    Study design considerations for trials to evaluate multicancer early detection assays for clinical utility

    by Lori M Minasian, Paul Pinsky, Hormuzd A Katki, Tony Dickherber, Paul K J Han, Lyndsay Harris, Christos Patriotis, Sudhir Srivastava, Carol J Weil, Philip C Prorok, et al.

    Blood-based assays using various technologies and biomarkers are in commercial development for the purpose of detecting multiple cancer types concurrently at an early stage of disease. These multicancer early detection (MCED) assays have the potential to improve the detection of cancers, particularly those for which no current screening modality exists. However, the unknown clinical benefits and harms of using MCED assays for cancer screening necessitate the development and implementation of a randomized controlled trial (RCT) to ascertain their clinical effectiveness. This was the consensus of experts at a National Cancer Institute–hosted workshop to discuss initial design concepts for such a trial. Using these assays to screen simultaneously for multiple cancers poses novel uncertainties for patient care compared with conventional screening tests for single cancers, such as establishing the diagnostic workup to confirm the presence of cancer at any organ site; clarifying appropriate follow-up for a positive assay for which there is no definitive diagnosis; identifying potential harms such as overdiagnosis of indolent disease; determining clinically effective and efficient strategies for disseminating MCED screening in real-world practice; and understanding the ethical implications, such as potentially alleviating or exacerbating existing health disparities. These assays present new and complex challenges for designing an RCT. Issues that emerged from the meeting centered around the need for a flexibly designed, clinical utility RCT to rigorously capture the evidence required to fully understand the net benefit of this promising technology. Specific topic areas were endpoints, screening protocols, recruitment, diagnostic pathway, pilot phase, data elements, specimen collection, and ethical considerations.


  • Top Cited Papers

    Synthetic biomarkers: a twenty-first century path to early cancer detection

    by Gabriel A. Kwong, Sharmistha Ghosh, Lena Gamboa, Christos Patriotis, Sudhir Srivastava, Sangeeta N. Bhatia

    Detection of cancer at an early stage when it is still localized improves patient response to medical interventions for most cancer types. The success of screening tools such as cervical cytology to reduce mortality has spurred significant interest in new methods for early detection (for example, using non-invasive blood-based or biofluid-based biomarkers). Yet biomarkers shed from early lesions are limited by fundamental biological and mass transport barriers — such as short circulation times and blood dilution — that limit early detection. To address this issue, synthetic biomarkers are being developed. These represent an emerging class of diagnostics that deploy bioengineered sensors inside the body to query early-stage tumours and amplify disease signals to levels that could potentially exceed those of shed biomarkers. These strategies leverage design principles and advances from chemistry, synthetic biology and cell engineering. In this Review, we discuss the rationale for development of biofluid-based synthetic biomarkers. We examine how these strategies harness dysregulated features of tumours to amplify detection signals, use tumour-selective activation to increase specificity and leverage natural processing of bodily fluids (for example, blood, urine and proximal fluids) for easy detection. Finally, we highlight the challenges that exist for preclinical development and clinical translation of synthetic biomarker diagnostics.


  • Open Access

    Normalization of single-channel DNA array data by principal component analysis

    by Radka Stoyanova, Troy D. Querec, Truman R. Brown, Christos Patriotis

    Motivation: Detailed comparison and analysis of the output of DNA gene expression arrays from multiple samples require global normalization of the measured individual gene intensities from the different hybridizations. This is needed for accounting for variations in array preparation and sample hybridization conditions. Results: Here, we present a simple, robust and accurate procedure for the global normalization of datasets generated with single-channel DNA arrays based on principal component analysis. The procedure makes minimal assumptions about the data and performs well in cases where other standard procedures produced biased estimates. It is also insensitive to data transformation, filtering (thresholding) and pre-screening.