Elisa Veridiani Soares
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elisa Veridiani Soares has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Giacobbo
Post-Graduation Program in Mining, Metallurgical and Materials Engineering (PPGE3M), Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves, n. 9500, Porto Alegre 91509-900, RS, Brazil
2 shared publications - Maria Norberta de Pinho
Centre of Physics and Engineering of Advanced Materials (CeFEMA), Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais, n. 1, 1049-001 Lisbon, Portugal
2 shared publications Andréa Moura Bernardes
Post-Graduation Program in Mining, Metallurgical and Materials Engineering (PPGE3M), Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves n. 9500, CEP: 91.509-900 Porto Alegre, Brazil
1 shared publication- Andréa Moura Bernardes
Post-Graduation Program in Mining, Metallurgical and Materials Engineering (PPGE3M), Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves, n. 9500, Porto Alegre 91509-900, RS, Brazil
1 shared publication - Daiana Seibert
Postgraduate Program of Environment and Sustainable Technologies, Federal University of Fronteira Sul, Rua Jacob Reinaldo Haupenthal 1580, CEP: 97900-00, Cerro Largo, RS, Brazil
1 shared publication - Eduardo Henrique Rotta
Programa de Pós-Graduação em Engenharia de Minas, Metalúrgica e de Materiais, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, Setor 4, Prédio 43426, Campus do Vale, Porto Alegre 91509-900, RS, Brazil
1 shared publication
Latest Publications
- Open Access
The Effect of pH on Atenolol/Nanofiltration Membranes Affinity
Nanofiltration has been shown to be effective in removing pharmaceutical compounds from water and wastewater, so different mechanisms can influence treatment performance. In the present work, we carried out a case study evaluating the performance of two nanofiltration membranes in the removal of Atenolol (ATN)—a pharmaceutical compound widely used for the treatment of arterial hypertension—under different conditions such as operating pressure, ATN concentration, and solution pH. By determining the B parameter, which quantifies the solute/membrane affinity, we verified that the solution pH influenced the performance of the membranes, promoting attraction or repulsion between the ATN and the membranes. At pH 2.5, both membranes and ATN were positively charged, causing electrostatic repulsion, showing lower values of the B parameter and, consequently, higher ATN rejections. At such a pH, the mean ATN rejection for the loose membrane (NF270) was 82%, while for the tight membrane (NF90) it was 88%. On the other hand, at 12 bar pressure, the NF70 membrane (5.1 × 10 −5 m s−1) presented mean permeate fluxes about 2.8 times greater than the NF90 membrane (1.8 × 10−5 m s−1), indicating that NF270 is the most suitable membrane for this application.
Open AccessThe Effect of pH on Atenolol/Nanofiltration Membranes Affinity
Nanofiltration has been shown to be effective in removing pharmaceutical compounds from water and wastewater, so different mechanisms can influence treatment performance. In the present work, we carried out a case study evaluating the performance of two nanofiltration membranes in the removal of Atenolol (ATN)—a pharmaceutical compound widely used for the treatment of arterial hypertension—under different conditions such as operating pressure, ATN concentration, and solution pH. By determining the B parameter, which quantifies the solute/membrane affinity, we verified that the solution pH influenced the performance of the membranes, promoting attraction or repulsion between the ATN and the membranes. At pH 2.5, both membranes and ATN were positively charged, causing electrostatic repulsion, showing lower values of the B parameter and, consequently, higher ATN rejections. At such a pH, the mean ATN rejection for the loose membrane (NF270) was 82%, while for the tight membrane (NF90) it was 88%. On the other hand, at 12 bar pressure, the NF70 membrane (5.1 × 10 −5 m s−1) presented mean permeate fluxes about 2.8 times greater than the NF90 membrane (1.8 × 10−5 m s−1), indicating that NF270 is the most suitable membrane for this application.
- 15 January 2020
- Published by IWA Publishing in Water Science & Technology
- Vol. 81 (2) , 210-216
Atenolol removal by nanofiltration: a case-specific mass transfer correlation
Concentration polarization is a phenomenon inherent to the membrane separation operations and as a precursor of membrane fouling is frequently related to the decrease in the performance of these operations. At the present work, a case-specific mass transfer correlation was developed to assess the concentration polarization when nanofiltration, in different operating conditions, was applied to treat a pharmaceutical wastewater containing atenolol. NF runs with two membranes, two atenolol concentrations and three feed circulating velocities were conducted, and the corresponding experimental mass transfer coefficients were determined using the film theory to describe the concentration polarization phenomenon. Higher velocities led to higher mass transfer coefficients and, consequently, lower concentration polarization. These mass transfer coefficients were correlated with the circulating velocity (Re), the solute diffusivity (Sc) and the membrane permeability (LP+) (the membrane is a permeable interface with effect on the concentration profiles developed from the interface towards the bulk feed), yielding the following correlation Sh = 1.98 × 104Re0.5Sc0.33LP+0.32. The good agreement between the calculated and the experimental results makes this correlation a valuable tool for water practitioners to predict and control the concentration polarization during atenolol-rich wastewater treatment by nanofiltration, therefore increasing its productivity and selectivity.
- 15 January 2020
- Published by IWA Publishing in Water Science & Technology
- Vol. 81 (2) , 210-216
Atenolol removal by nanofiltration: a case-specific mass transfer correlation
Concentration polarization is a phenomenon inherent to the membrane separation operations and as a precursor of membrane fouling is frequently related to the decrease in the performance of these operations. At the present work, a case-specific mass transfer correlation was developed to assess the concentration polarization when nanofiltration, in different operating conditions, was applied to treat a pharmaceutical wastewater containing atenolol. NF runs with two membranes, two atenolol concentrations and three feed circulating velocities were conducted, and the corresponding experimental mass transfer coefficients were determined using the film theory to describe the concentration polarization phenomenon. Higher velocities led to higher mass transfer coefficients and, consequently, lower concentration polarization. These mass transfer coefficients were correlated with the circulating velocity (Re), the solute diffusivity (Sc) and the membrane permeability (LP+) (the membrane is a permeable interface with effect on the concentration profiles developed from the interface towards the bulk feed), yielding the following correlation Sh = 1.98 × 104Re0.5Sc0.33LP+0.32. The good agreement between the calculated and the experimental results makes this correlation a valuable tool for water practitioners to predict and control the concentration polarization during atenolol-rich wastewater treatment by nanofiltration, therefore increasing its productivity and selectivity.
- 1 February 2018
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 6 (1) , 1390-1395
Bioassays and Zahn-Wellens test assessment on landfill leachate treated by photo-Fenton process
- 1 February 2018
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 6 (1) , 1390-1395
Bioassays and Zahn-Wellens test assessment on landfill leachate treated by photo-Fenton process