Wen Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wen Zhang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Yu-Ling He
Department of Mechanical Engineering, North China Electric Power University, Baoding 071003, China
11 shared publications - Ming-Xing Xu
Hebei Software Institute, Baoding, China
9 shared publications - David Gerada
University of Nottingham
7 shared publications David Gerada
Department of Electrical and Electronics Engineering, University of Nottingham, Nottingham, United Kingdom
5 shared publicationsDe-Rui Dai
North China Electric Power University
4 shared publicationsMing-Xing Xu
Baoding Key Laboratory of Intelligent Measurement and Control and Industrial Interconnection, Hebei Software Institute, Baoding, China
4 shared publications
Latest Publications
- 16 November 2026
- Published by SAGE Publications in Journal of Vibration and Control
Mechanism-guided vibration diagnosis of air-gap eccentricity in permanent magnet synchronous generators using multi-scale time–frequency learning
Air-gap eccentricity in permanent magnet synchronous generators produces non-stationary vibration responses with strong cross-band coupling, making fault-sensitive features difficult to extract. This study proposes a mechanism-guided diagnosis framework combining VMD-STFT-RGB representation with a multi-scale attention-enhanced ConvNeXt network. The electromechanical relationship among air-gap permeance distortion, unbalanced magnetic pull and structural vibration is first analyzed. VMD is then used to separate bearing-housing vibration signals into low-, middle- and high-frequency components, which are transformed by STFT and fused into RGB time-frequency images. The proposed MSA-ConvNeXt integrates multi-scale depthwise convolution, squeeze-and-excitation attention and cross-stage residual fusion. Under repeated five-fold acquisition-batch-wise cross-validation, the method achieved an accuracy of 97.86 ± 0.36%, a macro-F1 score of 0.9781 ± 0.0037 and a macro-AUC of 0.9885 ± 0.0032. The accuracy remained 93.18 ± 0.58% under 5 dB noise and reached 91.63 ± 1.13% on unseen compound eccentricity configurations. These results demonstrate the effectiveness, stability and robustness of the proposed method.
- 16 November 2026
- Published by SAGE Publications in Journal of Vibration and Control
Mechanism-guided vibration diagnosis of air-gap eccentricity in permanent magnet synchronous generators using multi-scale time–frequency learning
Air-gap eccentricity in permanent magnet synchronous generators produces non-stationary vibration responses with strong cross-band coupling, making fault-sensitive features difficult to extract. This study proposes a mechanism-guided diagnosis framework combining VMD-STFT-RGB representation with a multi-scale attention-enhanced ConvNeXt network. The electromechanical relationship among air-gap permeance distortion, unbalanced magnetic pull and structural vibration is first analyzed. VMD is then used to separate bearing-housing vibration signals into low-, middle- and high-frequency components, which are transformed by STFT and fused into RGB time-frequency images. The proposed MSA-ConvNeXt integrates multi-scale depthwise convolution, squeeze-and-excitation attention and cross-stage residual fusion. Under repeated five-fold acquisition-batch-wise cross-validation, the method achieved an accuracy of 97.86 ± 0.36%, a macro-F1 score of 0.9781 ± 0.0037 and a macro-AUC of 0.9885 ± 0.0032. The accuracy remained 93.18 ± 0.58% under 5 dB noise and reached 91.63 ± 1.13% on unseen compound eccentricity configurations. These results demonstrate the effectiveness, stability and robustness of the proposed method.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4541-4551
Investigation of End Winding Vibration Characteristics, Insulation Failure, and Protection in FESS
The permanent magnet synchronous motor/generator serves as the critical component for energy conversion in the flywheel energy storage system (FESS), and stator end winding insulation constitutes the important factor affecting system reliability and lifespan. Through the-oretical analysis, finite element analysis, and experimental verification, this article studies the vibration characteristics and insulation damage of end windings in FESS. First, the coupling model of end winding vibration is established considering the stator magnetic pull per unit area (MPPUA) and winding electromagnetic force (EF), and the stress intensity factor (SIF) is introduced to characterize the insulation damage behavior. Then, the vibration of the winding during charge, standby and discharge of FESS is calculated by field-circuit coupling and multiphysics coupling analysis, and the experimental verification is carried out. Finally, the SIF analysis of the crack is carried out using the transient structure field, and the experimental equipment is set up to complete the strain measurement of different end winding parts and the local reinforcement analysis. The methods and results of this article provide reference and guidance for the design, manufacture and maintenance of FESS.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4541-4551
Investigation of End Winding Vibration Characteristics, Insulation Failure, and Protection in FESS
The permanent magnet synchronous motor/generator serves as the critical component for energy conversion in the flywheel energy storage system (FESS), and stator end winding insulation constitutes the important factor affecting system reliability and lifespan. Through the-oretical analysis, finite element analysis, and experimental verification, this article studies the vibration characteristics and insulation damage of end windings in FESS. First, the coupling model of end winding vibration is established considering the stator magnetic pull per unit area (MPPUA) and winding electromagnetic force (EF), and the stress intensity factor (SIF) is introduced to characterize the insulation damage behavior. Then, the vibration of the winding during charge, standby and discharge of FESS is calculated by field-circuit coupling and multiphysics coupling analysis, and the experimental verification is carried out. Finally, the SIF analysis of the crack is carried out using the transient structure field, and the experimental equipment is set up to complete the strain measurement of different end winding parts and the local reinforcement analysis. The methods and results of this article provide reference and guidance for the design, manufacture and maintenance of FESS.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2337-2347
Temperature Distribution and Thermal Damage of End Winding in the Vehicle FESS
Flywheel energy storage system (FESS) has broad application prospects in new energy vehicles, but the lifespan of permanent magnet synchronous motor/generator (PMSM/G) insulation is an important factor restricting its development. This article focuses on the thermal damage problem of the end winding of PMSM/G in vehicle FESS, systematically revealing its temperature distribution characteristics, strain characteristics and insulation crack propagation mechanism. Firstly, the heat sources and dissipation of the PMSM/G in the charge, standby and discharge states are analyzed, and the insulation thermal stress and crack propagation are studied. Then the temperature, strain and crack stress intensity factor of the end winding are calculated by finite-element analysis. Finally, the differences in temperature and strain of the PMSM/G end winding under three states are verified through experiments. This research provides support for the end winding heat dissipation design and insulation system optimization of vehicle FESS.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2337-2347
Temperature Distribution and Thermal Damage of End Winding in the Vehicle FESS
Flywheel energy storage system (FESS) has broad application prospects in new energy vehicles, but the lifespan of permanent magnet synchronous motor/generator (PMSM/G) insulation is an important factor restricting its development. This article focuses on the thermal damage problem of the end winding of PMSM/G in vehicle FESS, systematically revealing its temperature distribution characteristics, strain characteristics and insulation crack propagation mechanism. Firstly, the heat sources and dissipation of the PMSM/G in the charge, standby and discharge states are analyzed, and the insulation thermal stress and crack propagation are studied. Then the temperature, strain and crack stress intensity factor of the end winding are calculated by finite-element analysis. Finally, the differences in temperature and strain of the PMSM/G end winding under three states are verified through experiments. This research provides support for the end winding heat dissipation design and insulation system optimization of vehicle FESS.
- 26 August 2025
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 32 (17-18) , 5158-5169
Rotor vibration analysis of off-grid PMSG considering axial eccentricity and load variability
This paper presents a comprehensive investigation into the effects of key operational parameters under axial eccentricity (AE) on the mechanical behavior of the rotor in permanent magnet synchronous generators (PMSGs). The parameters studied include the degree of AE, load size, and power factor. The rotor’s mechanical behaviors analyzed encompass unbalanced magnetic pull (UMP) and vibration responses. The research combines theoretical analysis, finite element analysis (FEA), and experimental validation. The findings indicate that UMP becomes significant under AE conditions, with a dominant frequency at 100 Hz. Moreover, as the degree of AE or the power factor increases, the 100 Hz of UMP and vibration responses also intensify. In contrast, larger load sizes result in reduced UMP and lower vibration amplitudes.
- 26 August 2025
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 32 (17-18) , 5158-5169
Rotor vibration analysis of off-grid PMSG considering axial eccentricity and load variability
This paper presents a comprehensive investigation into the effects of key operational parameters under axial eccentricity (AE) on the mechanical behavior of the rotor in permanent magnet synchronous generators (PMSGs). The parameters studied include the degree of AE, load size, and power factor. The rotor’s mechanical behaviors analyzed encompass unbalanced magnetic pull (UMP) and vibration responses. The research combines theoretical analysis, finite element analysis (FEA), and experimental validation. The findings indicate that UMP becomes significant under AE conditions, with a dominant frequency at 100 Hz. Moreover, as the degree of AE or the power factor increases, the 100 Hz of UMP and vibration responses also intensify. In contrast, larger load sizes result in reduced UMP and lower vibration amplitudes.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 13057-13076
UMP and Vibration Analysis for Eccentricity Detection in Permanent Magnet Synchronous Generators
This article investigates the unbalanced magnetic pull (UMP) and vibration characteristics in permanent magnet synchronous generators (PMSGs) under different types of air-gap eccentricity (AGE), including static eccentricity (SE), dynamic eccentricity (DE), and mixed eccentricity (ME). A novel experimental platform is designed to emulate various eccentricity conditions. Using the analytical modeling and finite-element analysis (FEA), the distinct UMP profiles are derived for SE, DE, and ME, and their effects on rotor vibration behavior are analyzed. Furthermore, the research reveals a direct correlation between UMP and spatial orientation of eccentricity faults. Experimental validations are conducted on a prototype generator, verifying the proposed analysis and highlighting the potential for eccentricity diagnosis using UMP and vibration features. It is shown that the spatial distribution of the UMP is point-like under SE, with its position corresponding to the location of the minimum air gap. The UMP distribution is circular under DE, with the position of the minimum air gap varying over time. In the case of ME, the UMP distribution forms an elliptical shape, and the center of this spatial distribution shifts toward the SE direction as the level of SE increases. Meanwhile, in the rotor vibration spectra, the dominant frequency component under SE is twice the electrical frequency ( $2f$ ). Under DE, the dominant component is the mechanical rotational frequency ( $f_{r}$ ). In ME, the vibration spectrum contains multiple frequency components, including $f_{r}$ , $2f_{r}$ , and $3f_{r}$ . These findings provide a useful reference for the monitoring and diagnosis of AGE.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 13057-13076
UMP and Vibration Analysis for Eccentricity Detection in Permanent Magnet Synchronous Generators
This article investigates the unbalanced magnetic pull (UMP) and vibration characteristics in permanent magnet synchronous generators (PMSGs) under different types of air-gap eccentricity (AGE), including static eccentricity (SE), dynamic eccentricity (DE), and mixed eccentricity (ME). A novel experimental platform is designed to emulate various eccentricity conditions. Using the analytical modeling and finite-element analysis (FEA), the distinct UMP profiles are derived for SE, DE, and ME, and their effects on rotor vibration behavior are analyzed. Furthermore, the research reveals a direct correlation between UMP and spatial orientation of eccentricity faults. Experimental validations are conducted on a prototype generator, verifying the proposed analysis and highlighting the potential for eccentricity diagnosis using UMP and vibration features. It is shown that the spatial distribution of the UMP is point-like under SE, with its position corresponding to the location of the minimum air gap. The UMP distribution is circular under DE, with the position of the minimum air gap varying over time. In the case of ME, the UMP distribution forms an elliptical shape, and the center of this spatial distribution shifts toward the SE direction as the level of SE increases. Meanwhile, in the rotor vibration spectra, the dominant frequency component under SE is twice the electrical frequency ( $2f$ ). Under DE, the dominant component is the mechanical rotational frequency ( $f_{r}$ ). In ME, the vibration spectrum contains multiple frequency components, including $f_{r}$ , $2f_{r}$ , and $3f_{r}$ . These findings provide a useful reference for the monitoring and diagnosis of AGE.
- 24 April 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (5) , 056110
Eccentricity fault diagnosis of permanent magnet synchronous generators based on 2D recursive fusion graph and CBAM-ConvNeXt-FPN
To detect the eccentricity fault of permanent magnet synchronous generator (PMSG) and ensure the stable operation of the equipment, a new method based on multi-channel signal 2D recursive fusion combined with Convolutional Block Attention Module (CBAM)-ConvNeXt-FPN is proposed to detect complex eccentricity faults of PMSG in this work. First, the 1D three-phase current signals are mapped into 2D images and fused across multiple channels to enhance the richness and complementarity of fault feature information. Hereafter, a novel multi-scale fusion classification deep learning framework, named CBAM-ConvNeXt-FPN, is proposed to capture both local and global information from feature maps, conduct deep fault feature extraction, and improve feature representation capability, achieving precise classification of complex eccentric faults across fault types. Experimental results from the test platform demonstrate that the diagnostic accuracy of the CBAM-ConvNeXt-FPN model reaches 99.08%, outperforming comparison models such as Swin Transformer. The robustness of the model was verified through noise experiments and load fluctuation tests. The results show that under noisy environments or load fluctuation conditions, the accuracy of this model remains within a stable range and is higher than that of other models. These results confirm the superiority and effectiveness of the proposed approach.
- 24 April 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (5) , 056110
Eccentricity fault diagnosis of permanent magnet synchronous generators based on 2D recursive fusion graph and CBAM-ConvNeXt-FPN
To detect the eccentricity fault of permanent magnet synchronous generator (PMSG) and ensure the stable operation of the equipment, a new method based on multi-channel signal 2D recursive fusion combined with Convolutional Block Attention Module (CBAM)-ConvNeXt-FPN is proposed to detect complex eccentricity faults of PMSG in this work. First, the 1D three-phase current signals are mapped into 2D images and fused across multiple channels to enhance the richness and complementarity of fault feature information. Hereafter, a novel multi-scale fusion classification deep learning framework, named CBAM-ConvNeXt-FPN, is proposed to capture both local and global information from feature maps, conduct deep fault feature extraction, and improve feature representation capability, achieving precise classification of complex eccentric faults across fault types. Experimental results from the test platform demonstrate that the diagnostic accuracy of the CBAM-ConvNeXt-FPN model reaches 99.08%, outperforming comparison models such as Swin Transformer. The robustness of the model was verified through noise experiments and load fluctuation tests. The results show that under noisy environments or load fluctuation conditions, the accuracy of this model remains within a stable range and is higher than that of other models. These results confirm the superiority and effectiveness of the proposed approach.
- 21 August 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (1) , 605-619
Impact of 2D and 3D Rotor Eccentricity on End Winding Mechanics Behavior in Synchronous Generators
- 21 August 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (1) , 605-619
Impact of 2D and 3D Rotor Eccentricity on End Winding Mechanics Behavior in Synchronous Generators
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5156-5168
Loss, Thermal and Mechanical Responses of Rotor in Marine Generators Under SISC Degree and Load Variation
The electric power supply on marine ships depends on the generator. Once the generator fails, it affects the operation of the marine ships. Stator interturn short circuit (SISC) is a common electrical fault in generators. In the case of a short circuit fault, the generator will be in the reinforced exciting current (REC) mode. At present, most research results mainly focus on fault detection methods, rarely concentrating on rotor temperature properties. In this article, the air gap magnetic flux density (MFD) model in the combination of different loads and SISC degrees is established, and the characteristics of the terminal voltage are presented. Moreover, the change rule of the stator current, MFD, and the loss of rotor are comprehensively investigated while considering REC mode. To reveal the law of the rotor thermal response and the biggest value of the deformation/stress/strain at the rotor core acted by temperature, the multiphysics field analysis model with electromagnetic-temperature-structure coupling is established. Experiments are carried out to verify the theoretical and finite element analysis (FEA) correctness by a 5 kW prototype generator.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5156-5168
Loss, Thermal and Mechanical Responses of Rotor in Marine Generators Under SISC Degree and Load Variation
The electric power supply on marine ships depends on the generator. Once the generator fails, it affects the operation of the marine ships. Stator interturn short circuit (SISC) is a common electrical fault in generators. In the case of a short circuit fault, the generator will be in the reinforced exciting current (REC) mode. At present, most research results mainly focus on fault detection methods, rarely concentrating on rotor temperature properties. In this article, the air gap magnetic flux density (MFD) model in the combination of different loads and SISC degrees is established, and the characteristics of the terminal voltage are presented. Moreover, the change rule of the stator current, MFD, and the loss of rotor are comprehensively investigated while considering REC mode. To reveal the law of the rotor thermal response and the biggest value of the deformation/stress/strain at the rotor core acted by temperature, the multiphysics field analysis model with electromagnetic-temperature-structure coupling is established. Experiments are carried out to verify the theoretical and finite element analysis (FEA) correctness by a 5 kW prototype generator.
- Open Access
- 6 July 2024
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 105, 370-380
A comprehensive study on electromagnetic torque and rotor UMP based on an improved 3D static air-gap eccentricity model
- 6 July 2024
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 105, 370-380
Open AccessA comprehensive study on electromagnetic torque and rotor UMP based on an improved 3D static air-gap eccentricity model
- Open Access
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 7794-7807
Analysis of Stator Vibration Characteristics in Synchronous Generators Considering Inclined Static Air Gap Eccentricity
This paper mainly focuses on the impact of inclined static air gap eccentricity (ISAGE) on the electromagnetic characteristics and mechanical performances (vibration, deformation, strain and stress). Considering different ISAGE fault types in the theoretical and finite element analysis (FEA) model of synchronous generators, the effects of intersection position of the rotor center axis and stator center axis, rotor inclined angle, and the combination of the previous two fault types on MFD, phase current and radial magnetic pulling per unit area (MPPUA) are analyzed and compared. Then, based on the stator model used uniformly in three physical fields, the harmonic response and mechanical response are investigated with loads imported by the electromagnetic field. Finally, the stator radial vibration measurement experiments are carried out to verify the results obtained by theoretical analysis and FEA. It is shown that ISAGE will considerably enlarge the fluctuation of MPPUA and intensify the radial vibration of the stator, especially at the 2nd harmonic. The probability of failure at tooth tip and inner slot wall of the stator will increase.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 7794-7807
Open AccessAnalysis of Stator Vibration Characteristics in Synchronous Generators Considering Inclined Static Air Gap Eccentricity
This paper mainly focuses on the impact of inclined static air gap eccentricity (ISAGE) on the electromagnetic characteristics and mechanical performances (vibration, deformation, strain and stress). Considering different ISAGE fault types in the theoretical and finite element analysis (FEA) model of synchronous generators, the effects of intersection position of the rotor center axis and stator center axis, rotor inclined angle, and the combination of the previous two fault types on MFD, phase current and radial magnetic pulling per unit area (MPPUA) are analyzed and compared. Then, based on the stator model used uniformly in three physical fields, the harmonic response and mechanical response are investigated with loads imported by the electromagnetic field. Finally, the stator radial vibration measurement experiments are carried out to verify the results obtained by theoretical analysis and FEA. It is shown that ISAGE will considerably enlarge the fluctuation of MPPUA and intensify the radial vibration of the stator, especially at the 2nd harmonic. The probability of failure at tooth tip and inner slot wall of the stator will increase.