Jae Wook Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jae Wook Lee has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Kyung Hyun Choi
Department of Mechatronics Engineering, Jeju National University, Jeju, Republic of Korea
4 shared publications - Arun Asif
Advanced Micro Mechatronics Lab, Department of Mechatronics Engineering, Jeju National University, Jeju-si 63243, Jeju-do, Korea
2 shared publications - Fida Hussain Memon
Department of Mechatronics Engineering, Jeju National University, Jeju 63243, Republic of Korea
2 shared publications - Abdul Khalique
Department of Metallurgy and Materials Engineering, Mehran University of Engineering & Technology, Jamshoro 76062, Pakistan
1 shared publication - Abdul Rahim Chethikkattuveli Salih
Department of Mechatronics Engineering, Jeju National University, Jeju-si 63243, Korea
1 shared publication - Abdul Rahim Chethikkattuveli Salih
Department of Mechatronics Engineering, Jeju National University, Jeju-si 63243, Korea
1 shared publication
Latest Publications
- Open Access
- 16 December 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (12) , 3418
Silicone Elastomer Composites Fabricated with MgO and MgO-Multi-Wall Carbon Nanotubes with Improved Thermal Conductivity
The effect of multiwall carbon nanotubes (MWCNTs) and magnesium oxide (MgO) on the thermal conductivity of MWCNTs and MgO-reinforced silicone rubber was studied. The increment of thermal conductivity was found to be linear with respect to increased loading of MgO. In order to improve the thermal transportation of phonons 0.3 wt % and 0.5 wt % of MWCNTs were added as filler to MgO-reinforced silicone rubber. The MWCNTs were functionalized by hydrogen peroxide (H2O2) to activate organic groups onto the surface of MWCNTs. These functional groups improved the compatibility and adhesion and act as bridging agents between MWCNTs and silicone elastomer, resulting in the formation of active conductive pathways between MgO and MWCNTs in the silicone elastomer. The surface functionalization was confirmed with XRD and FTIR spectroscopy. Raman spectroscopy confirms the pristine structure of MWCNTs after oxidation with H2O2. The thermal conductivity is improved to 1 W/m·K with the addition of 20 vol% with 0.5 wt % of MWCNTs, which is an ~8-fold increment in comparison to neat elastomer. Improved thermal conductive properties of MgO-MWCNTs elastomer composite will be a potential replacement for conventional thermal interface materials.
- 16 December 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (12) , 3418
Open AccessSilicone Elastomer Composites Fabricated with MgO and MgO-Multi-Wall Carbon Nanotubes with Improved Thermal Conductivity
The effect of multiwall carbon nanotubes (MWCNTs) and magnesium oxide (MgO) on the thermal conductivity of MWCNTs and MgO-reinforced silicone rubber was studied. The increment of thermal conductivity was found to be linear with respect to increased loading of MgO. In order to improve the thermal transportation of phonons 0.3 wt % and 0.5 wt % of MWCNTs were added as filler to MgO-reinforced silicone rubber. The MWCNTs were functionalized by hydrogen peroxide (H2O2) to activate organic groups onto the surface of MWCNTs. These functional groups improved the compatibility and adhesion and act as bridging agents between MWCNTs and silicone elastomer, resulting in the formation of active conductive pathways between MgO and MWCNTs in the silicone elastomer. The surface functionalization was confirmed with XRD and FTIR spectroscopy. Raman spectroscopy confirms the pristine structure of MWCNTs after oxidation with H2O2. The thermal conductivity is improved to 1 W/m·K with the addition of 20 vol% with 0.5 wt % of MWCNTs, which is an ~8-fold increment in comparison to neat elastomer. Improved thermal conductive properties of MgO-MWCNTs elastomer composite will be a potential replacement for conventional thermal interface materials.
- Open Access
Two-Dimensional Transition Metal Carbides and Nitrides (MXenes) for Water Purification and Antibacterial Applications
Two-dimensional (2D) materials such as graphene, graphene oxide (GO), metal carbides and nitrides (MXenes), transition metal dichalcogenides (TMDS), boron nitride (BN), and layered double hydroxide (LDH) metal–organic frameworks (MOFs) have been widely investigated as potential candidates in various separation applications because of their high mechanical strength, large surface area, ideal chemical and thermal stability, simplicity, ease of functionalization, environmental comparability, and good antibacterial performance. Recently, MXene as a new member of the 2D polymer family has attracted significant attention in water purification, desalination, gas separation, antibacterial, and antifouling applications. Herein, we review the most recent progress in the fabrication, preparation, and modification methods of MXene-based lamellar membranes with the emphasis on applications for water purification and desalination. Moreover, the antibacterial properties of MXene-based membranes show a significant potential for commercial use in water purification. Thus, this review provides a directional guide for future development in this emerging technology.
Open AccessTwo-Dimensional Transition Metal Carbides and Nitrides (MXenes) for Water Purification and Antibacterial Applications
Two-dimensional (2D) materials such as graphene, graphene oxide (GO), metal carbides and nitrides (MXenes), transition metal dichalcogenides (TMDS), boron nitride (BN), and layered double hydroxide (LDH) metal–organic frameworks (MOFs) have been widely investigated as potential candidates in various separation applications because of their high mechanical strength, large surface area, ideal chemical and thermal stability, simplicity, ease of functionalization, environmental comparability, and good antibacterial performance. Recently, MXene as a new member of the 2D polymer family has attracted significant attention in water purification, desalination, gas separation, antibacterial, and antifouling applications. Herein, we review the most recent progress in the fabrication, preparation, and modification methods of MXene-based lamellar membranes with the emphasis on applications for water purification and desalination. Moreover, the antibacterial properties of MXene-based membranes show a significant potential for commercial use in water purification. Thus, this review provides a directional guide for future development in this emerging technology.
- Open Access
- 1 October 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (10) , 1369
Gravity-Based Flow Efficient Perfusion Culture System for Spheroids Mimicking Liver Inflammation
The spheroid culture system provides an efficient method to emulate organ-specific pathophysiology, overcoming the traditional two-dimensional (2D) cell culture limitations. The intervention of microfluidics in the spheroid culture platform has the potential to enhance the capacity of in vitro microphysiological tissues for disease modeling. Conventionally, spheroid culture is carried out in static conditions, making the media nutrient-deficient around the spheroid periphery. The current approach tries to enhance the capacity of the spheroid culture platform by integrating the perfusion channel for dynamic culture conditions. A pro-inflammatory hepatic model was emulated using a coculture of HepG2 cell line, fibroblasts, and endothelial cells for validating the spheroid culture plate with a perfusable channel across the spheroid well. Enhanced proliferation and metabolic capacity of the microphysiological model were observed and further validated by metabolic assays. A comparative analysis of static and dynamic conditions validated the advantage of spheroid culture with dynamic media flow. Hepatic spheroids were found to have improved proliferation in dynamic flow conditions as compared to the static culture platform. The perfusable culture system for spheroids is more physiologically relevant as compared to the static spheroid culture system for disease and drug analysis.
- 1 October 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (10) , 1369
Open AccessGravity-Based Flow Efficient Perfusion Culture System for Spheroids Mimicking Liver Inflammation
The spheroid culture system provides an efficient method to emulate organ-specific pathophysiology, overcoming the traditional two-dimensional (2D) cell culture limitations. The intervention of microfluidics in the spheroid culture platform has the potential to enhance the capacity of in vitro microphysiological tissues for disease modeling. Conventionally, spheroid culture is carried out in static conditions, making the media nutrient-deficient around the spheroid periphery. The current approach tries to enhance the capacity of the spheroid culture platform by integrating the perfusion channel for dynamic culture conditions. A pro-inflammatory hepatic model was emulated using a coculture of HepG2 cell line, fibroblasts, and endothelial cells for validating the spheroid culture plate with a perfusable channel across the spheroid well. Enhanced proliferation and metabolic capacity of the microphysiological model were observed and further validated by metabolic assays. A comparative analysis of static and dynamic conditions validated the advantage of spheroid culture with dynamic media flow. Hepatic spheroids were found to have improved proliferation in dynamic flow conditions as compared to the static culture platform. The perfusable culture system for spheroids is more physiologically relevant as compared to the static spheroid culture system for disease and drug analysis.
- Open Access
Extracellular Matrix Optimization for Enhanced Physiological Relevance in Hepatic Tissue-Chips
The cellular microenvironment is influenced explicitly by the extracellular matrix (ECM), the main tissue support biomaterial, as a decisive factor for tissue growth patterns. The recent emergence of hepatic microphysiological systems (MPS) provide the basic physiological emulation of the human liver for drug screening. However, engineering microfluidic devices with standardized surface coatings of ECM may improve MPS-based organ-specific emulation for improved drug screening. The influence of surface coatings of different ECM types on tissue development needs to be optimized. Additionally, an intensity-based image processing tool and transepithelial electrical resistance (TEER) sensor may assist in the analysis of tissue formation capacity under the influence of different ECM types. The current study highlights the role of ECM coatings for improved tissue formation, implying the additional role of image processing and TEER sensors. We studied hepatic tissue formation under the influence of multiple concentrations of Matrigel, collagen, fibronectin, and poly-L-lysine. Based on experimental data, a mathematical model was developed, and ECM concentrations were validated for better tissue development. TEER sensor and image processing data were used to evaluate the development of a hepatic MPS for human liver physiology modeling. Image analysis data for tissue formation was further strengthened by metabolic quantification of albumin, urea, and cytochrome P450. Standardized ECM type for MPS may improve clinical relevance for modeling hepatic tissue microenvironment, and image processing possibly enhance the tissue analysis of the MPS.
Open AccessExtracellular Matrix Optimization for Enhanced Physiological Relevance in Hepatic Tissue-Chips
The cellular microenvironment is influenced explicitly by the extracellular matrix (ECM), the main tissue support biomaterial, as a decisive factor for tissue growth patterns. The recent emergence of hepatic microphysiological systems (MPS) provide the basic physiological emulation of the human liver for drug screening. However, engineering microfluidic devices with standardized surface coatings of ECM may improve MPS-based organ-specific emulation for improved drug screening. The influence of surface coatings of different ECM types on tissue development needs to be optimized. Additionally, an intensity-based image processing tool and transepithelial electrical resistance (TEER) sensor may assist in the analysis of tissue formation capacity under the influence of different ECM types. The current study highlights the role of ECM coatings for improved tissue formation, implying the additional role of image processing and TEER sensors. We studied hepatic tissue formation under the influence of multiple concentrations of Matrigel, collagen, fibronectin, and poly-L-lysine. Based on experimental data, a mathematical model was developed, and ECM concentrations were validated for better tissue development. TEER sensor and image processing data were used to evaluate the development of a hepatic MPS for human liver physiology modeling. Image analysis data for tissue formation was further strengthened by metabolic quantification of albumin, urea, and cytochrome P450. Standardized ECM type for MPS may improve clinical relevance for modeling hepatic tissue microenvironment, and image processing possibly enhance the tissue analysis of the MPS.