Matheus Gonçalves Silqueira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matheus Gonçalves Silqueira has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alex Takeo Yasumura Lima Silva
Universidade Federal de Itajubá
3 shared publications - Fernando das Graças Braga da Silva
Universidade Federal de Itajubá
3 shared publications - Matheus David Guimarães Barbedo
Universidade Federal de Itajubá
2 shared publications - Claudio Abiar Lourenço
Universidade Federal de Itajubá
1 shared publication - José Antonio Tosta dos Reis
Universidade Federal do Espirito Santo
1 shared publication - Lorena Lemos Dias Lara
Instituto de Recursos Naturais, Universidade Federal de Itajub (UNIFEI), Itajuba, Brazil
1 shared publication
Latest Publications
- Open Access
- 5 September 2024
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 18 (10) , e08935
Correlation of Water and Energy Parameters in a South of Minas Gerais Water Supply System
Objective: The objective of this study is to investigate the correlation between water and energy parameters in order to obtain water and energy consumption, according to studies by a local water utility. Theoretical Framework: The main theories presented here are the water and energy balances of a water supply network, whose authors can be found throughout the work. Such concepts are fundamental, as they allow correlating the parameters that are the objective of the study. Method: The methodology adopted for this research comprises a literature review to obtain the necessary theoretical basis, as well as data collection carried out through campaigns by the research group throughout its trajectory, in previous works. The processing of the collected data was carried out using water and energy balances, with the consequent correlation of such parameters in relation to water losses in the sector under study. Results and Discussion: The results obtained revealed that losses can reach up to R$249,949.06 in 5 years in the sector under study, reconciling water and energy losses due to the inefficiency of the system under study. Research Implications: This research, due to its approach, can guide measures to increase water and energy efficiency in sanitation companies, resulting in important financial and environmental gains for society by reducing water and energy waste and reducing operating costs, with resulting financial relief for society. Originality/Value: This study contributes to the literature by correlating water and energy parameters in the study of water distribution losses, having revealed the monetary values of the losses and their impacts on society.
- 5 September 2024
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 18 (10) , e08935
Open AccessCorrelation of Water and Energy Parameters in a South of Minas Gerais Water Supply System
Objective: The objective of this study is to investigate the correlation between water and energy parameters in order to obtain water and energy consumption, according to studies by a local water utility. Theoretical Framework: The main theories presented here are the water and energy balances of a water supply network, whose authors can be found throughout the work. Such concepts are fundamental, as they allow correlating the parameters that are the objective of the study. Method: The methodology adopted for this research comprises a literature review to obtain the necessary theoretical basis, as well as data collection carried out through campaigns by the research group throughout its trajectory, in previous works. The processing of the collected data was carried out using water and energy balances, with the consequent correlation of such parameters in relation to water losses in the sector under study. Results and Discussion: The results obtained revealed that losses can reach up to R$249,949.06 in 5 years in the sector under study, reconciling water and energy losses due to the inefficiency of the system under study. Research Implications: This research, due to its approach, can guide measures to increase water and energy efficiency in sanitation companies, resulting in important financial and environmental gains for society by reducing water and energy waste and reducing operating costs, with resulting financial relief for society. Originality/Value: This study contributes to the literature by correlating water and energy parameters in the study of water distribution losses, having revealed the monetary values of the losses and their impacts on society.
- Open Access
- 12 September 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (12)
Methodological analysis for assessing the relation of the energy cost with losses of water – a case study
The rational use of energy is being increasingly encouraged. In some countries, there are even subsidies for industries to adopt energy efficiency measures. One of the sectors with great opportunities for efficiency is sanitation, where a large part of energy consumption refers to pumping stations. The objective of this work is to demonstrate the consumption of electrical energy and possible reduction of electrical energy consumption in a sector of study of the Autonomous Water and Sewage Service (SAAE) of the municipality in the south of Minas Gerais. To determine the measures to be taken to reduce energy costs, it is necessary to perform a system diagnosis. For this, field trials were carried out. The study sector had an average expense of R$ 42,097.44/year due to water losses in the system. When considering only electricity costs, they represent 34.20% of the costs in relation to water losses (R$ 14,395.90/year). The system presented 27.73% of total water losses, an energy consumption of 0.6627 kWh/m³ only for the R3 pumping station and 1.302 kWh/m³ when also considering the Water Collection and Treatment Plant (WTP).
- 12 September 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (12)
Open AccessMethodological analysis for assessing the relation of the energy cost with losses of water – a case study
The rational use of energy is being increasingly encouraged. In some countries, there are even subsidies for industries to adopt energy efficiency measures. One of the sectors with great opportunities for efficiency is sanitation, where a large part of energy consumption refers to pumping stations. The objective of this work is to demonstrate the consumption of electrical energy and possible reduction of electrical energy consumption in a sector of study of the Autonomous Water and Sewage Service (SAAE) of the municipality in the south of Minas Gerais. To determine the measures to be taken to reduce energy costs, it is necessary to perform a system diagnosis. For this, field trials were carried out. The study sector had an average expense of R$ 42,097.44/year due to water losses in the system. When considering only electricity costs, they represent 34.20% of the costs in relation to water losses (R$ 14,395.90/year). The system presented 27.73% of total water losses, an energy consumption of 0.6627 kWh/m³ only for the R3 pumping station and 1.302 kWh/m³ when also considering the Water Collection and Treatment Plant (WTP).
- Open Access
- 3 August 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (10)
A water-energy balance application with adaptations to a brazilian water supply system
According to the Alliance to Save Energy, between 2 % and 3 % of the total electric energy consumed in the world is used for water pumping in supply systems, with the consumption reduction potential through energy efficiency and conservation measures being estimated at 25 %. In Brazil, the water supply sector corresponds to 2.6 % of the total energy consumed in the country, with pumping systems being responsible for over 90 % of the total energy consumption. It is extremely common to find supersized facilities with pump motor sets operating outside their ideal points, with it being a common practice to perform flow and pressure control through the installation of valves. The use of reducing valves inserts unnecessary pressure drops into the hydraulic system, increasing energy consumption. The objective of this work is to present an energy balance of a study sector of the Autonomous Water and Sewage Service (AWSS) of a municipality in the south of Minas Gerais, Brazil, aiming to elucidate the electric energy consumption of the system and where the reduction in such consumption may occur. For this, we measured data such as the efficiency of the pump motor sets, calculated performance indicators and water loss indices, and applied the energy balance adapted. This work presents an application of a water-energy balance with adaptations to a Brazilian water supply system, under the perspective of the energy efficiency in lift station pump motor sets.
- 3 August 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (10)
Open AccessA water-energy balance application with adaptations to a brazilian water supply system
According to the Alliance to Save Energy, between 2 % and 3 % of the total electric energy consumed in the world is used for water pumping in supply systems, with the consumption reduction potential through energy efficiency and conservation measures being estimated at 25 %. In Brazil, the water supply sector corresponds to 2.6 % of the total energy consumed in the country, with pumping systems being responsible for over 90 % of the total energy consumption. It is extremely common to find supersized facilities with pump motor sets operating outside their ideal points, with it being a common practice to perform flow and pressure control through the installation of valves. The use of reducing valves inserts unnecessary pressure drops into the hydraulic system, increasing energy consumption. The objective of this work is to present an energy balance of a study sector of the Autonomous Water and Sewage Service (AWSS) of a municipality in the south of Minas Gerais, Brazil, aiming to elucidate the electric energy consumption of the system and where the reduction in such consumption may occur. For this, we measured data such as the efficiency of the pump motor sets, calculated performance indicators and water loss indices, and applied the energy balance adapted. This work presents an application of a water-energy balance with adaptations to a Brazilian water supply system, under the perspective of the energy efficiency in lift station pump motor sets.