GAGadir Ahmadov

Gadir Ahmadov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gadir Ahmadov has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of YSO–SiPM detector response for alpha spectroscopy applications

    by Gadir Ahmadov, Sebuhi Nuruyev, Daniyar Berikov, Arzu Mammadli, Azer Sadygov, Alisher Temirzhanov, Kairat Mendibayev, Murad Kenessarin, Ramil Akbarov, Farid Ahmadov

    Background Alpha-particle spectroscopy is widely used in nuclear physics, radiation monitoring, safeguards, and environmental measurements. Conventional silicon detectors provide excellent spectrometric performance; however, their application in portable or harsh-environment instrumentation may be limited by mechanical fragility, radiation sensitivity, and operational constraints. Scintillator-based detectors coupled to silicon photomultipliers (SiPMs) represent a promising alternative because of their compactness, robustness, and simplified integration with modern electronics. Despite the favorable scintillation properties of yttrium orthosilicate (YSO), its applicability for alpha-particle spectroscopy has received limited investigation. Methods The response of a YSO scintillator coupled to a Hamamatsu S13360–3050 multi-pixel photon counter (MPPC) array was investigated using alpha particles emitted from a 238Pu source. A 10 × 10 × 10 mm 3 YSO crystal was coupled to the SiPM array and read out using CAEN digitization electronics. Alpha-particle energies in the approximate range from 0.4 MeV to 5.5 MeV were obtained by varying the air-layer thickness between the radioactive source and detector. Signal acquisition was performed using a CAEN DT5720 digitizer operated in self-trigger mode, while offline waveform processing was performed using ROOT-based software. Results The YSO–SiPM detector exhibited stable and approximately linear response characteristics across the investigated energy interval. The measured deviation from linearity was approximately 3%. The experimentally determined alpha-particle flight distance in air was measured as 40.58 ± 0.87 mm, in good agreement with SRIM simulations predicting approximately 42 mm. The measured energy resolution varied from approximately 10.5% at 5.5 MeV to approximately 21% at lower alpha-particle energies near 0.4 MeV. Alpha-particle signals remained clearly distinguishable down to approximately 500 keV. Conclusions The obtained results demonstrate that the YSO-SiPM configuration represents a compact and mechanically robust detector solution for alpha-particle spectroscopy. Although the energy resolution remains inferior to conventional silicon alpha detectors, the investigated system offers important practical advantages including operation under ambient conditions, simplified electronics integration, scalability, and suitability for portable or harsh-environment nuclear instrumentation.

  • Open Access

    Development of high-efficiency micropixel avalanche photodiodes with fast recovery time and enhanced photon detection efficiency

    by Arzu Mammadli, Gadir Ahmadov, Sebuhi Nuruyev, Daniyar Berikov, Azer Sadygov, Alisher Temirzhanov, Kairat Mendibayev, Murad Kenessarin, Ramil Akbarov, Farid Ahmadov

    Background Silicon photo-multipliers (SiPMs) suffer from several important limitations, including long recovery time, dead-space losses caused by surface quenching resistors, limited photon detection efficiency (PDE), and saturation effects under high particle flux conditions. These drawbacks significantly restrict detector performance in high-rate timing applications, radiation monitoring systems, and modern scintillation detectors. Methods Novel MAPD structures employing artificial potential micro-wells and intrinsic micro-channel recovery mechanisms were developed using silicon epitaxial technology. Electrical and optical properties of the devices were experimentally investigated through capacitance-voltage measurements, PDE analysis, and recovery-time characterization. Optimized thin-film bilayers of silicon nitride (Si 3N 4) and silicon dioxide (SiO 2) were further implemented as anti-reflection coatings to maximize quantum efficiency (QE). Results The proposed MAPD structure demonstrated substantial improvements compared to conventional structures. The developed devices achieved nearly 100% photosensitive surface coverage, pixel densities up to 2.8 × 10 4 pixels/mm 2, and PDE approaching 40%. Experimental investigations showed that the recovery time was reduced from approximately 300 μs to 40 ns, corresponding to an improvement factor of approximately 7.5 × 10 3. Conclusions The obtained results demonstrate that optimized electric-field engineering combined with intrinsic micro-channel recovery mechanisms significantly improves both PDE and detector recovery dynamics. The proposed structures represent promising candidates for next-generation high-rate silicon photo-detectors intended for fast timing systems, TOF-PET, scintillation detectors, and high-energy physics experiments.

  • Open Access

    Investigation of YSO–SiPM detector response for alpha spectroscopy applications

    by Gadir Ahmadov, Sabuhi Nuruyev

    The applicability of a yttrium orthosilicate (YSO) scintillator coupled to a silicon photomultiplier (SiPM) array for alpha-particle spectrometry was investigated. Although scintillators such as ZnS(Ag) and CsI(Tl) are widely used for alpha detection, the alpha-spectrometric performance of YSO scintillators has received limited attention. In this work, alpha particles from a ²³⁸Pu source were measured in the energy range from approximately 0.4 MeV to 5.5 MeV by varying the air gap between the source and detector. A 10×10×10 mm³ YSO crystal was coupled to a Hamamatsu S13360-3050 multi-pixel photon counter (MPPC) array and read out using CAEN digitization electronics. The detector exhibited stable and approximately linear response behavior across the investigated energy interval, with an estimated deviation of about 3% from linearity. The measured energy resolution varied from approximately 10.5% at 5.5 MeV to 21% at 0.4 MeV. The experimentally measured alpha-particle flight distance in air was consistent with SRIM simulations. The obtained results demonstrate that the YSO–SiPM configuration represents a promising compact and mechanically robust solution for alpha spectrometry, radiation monitoring, safeguards, and field-deployable nuclear instrumentation.

  • Cross sections of the 148Sm(n,α)145Nd reaction in the 4.8–5.3 MeV neutron energy range*

    by I. Chuprakov, E. Sansarbayar, Guohui国辉Zhang张, Yu.M. Gledenov, L. Krupa, Jie杰Liu刘, Haofan浩帆Bai白, Cong聪Xia夏, Zepeng泽鹏Wu邬, Wenkai文凯Ren任, et al.

    The cross sections of the 148Sm(n,α)145Nd reaction were measured for the first time at neutron energies ranging from 4.8 to 5.3 MeV. The experiment was carried out on the Van de Graaff accelerator EG–5 at the Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research. Fast neutrons were produced via the 2H(d,n)3He reaction with a deuterium gas target. A twin gridded ionization chamber was used as the charged particle detector, with back–to–back 148Sm samples mounted on tantalum backings at the common cathode. The absolute neutron flux was measured using the 238U3O8 sample. The obtained cross section data were compared with those from existing nuclear data libraries and theoretical calculations using the TALYS–1.96 code. The present results for the 148Sm(n,α)145Nd reaction are expected to resolve discrepancies among various nuclear evaluation data.


  • Rotation effect of a fissile nucleus (ROT effect) for prompt γ-rays in binary fission of 235U by polarized neutrons of different energies*

    by D. Berikov, G. Ahmadov, Yu. Kopatch, A. Gagarski, G. Danilyan, I. Chuprakov, F. Ahmadov, K. Mendibayev, S. Nuruyev

    This article describes a series of studies on the effect of the rotation of the fissile 236U nucleus in the 235U(n,f) process induced by monochromatic polarized neutrons with energies of 62 meV and 270 meV. The studied effect is expressed as a shift in the anisotropic angular distribution of γ-rays emitted by excited fission fragments by a small angle relative to the deformation axis of the fissile nucleus when the neutron beam polarization direction is reversed. All measurements were performed at the Heinz Mayer-Leibniz research neutron source (FRM II reactor) of the Munich Technical University in Garching on the polarized neutron beam of the POLI instrument. To generalize all results obtained on ROT effects for fission γ-rays, the results of earlier studies by the ITEP group for cold neutrons are re-processed, and the result obtained by the PNPI group for thermal neutrons is also presented.

  • Open Access

    Characterization of silicon photomultipliers with different structures

    by Sabuhi Nuruyev, Aleksandr Nartov, Ramil Akbarov, Gadir Ahmadov, Daniyar Berikov, Farid Ahmadov, Jalal Naghiyev, Azer Sadygov, Rauf Sardarli, Michael Holik

    Background Silicon Photomultipliers (SiPMs) are crucial devices in various photon-counting applications. They are mainly produced with two pixel structures, with deeply burned and surface pixel designs offering distinct advantages. This study investigates the impact of these structural differences on key parameters of two representative SiPMs: the MAPD-3NM-II (Zecotek Photonics) with a deeply burned structure and the MPPC S12572-010P (Hamamatsu Photonics) with a surface pixel structure. Method The performance of MAPD-3NM-II and MPPC S12572-010P was evaluated using multiple techniques. Breakdown voltage was determined using three different methods: I-V measurements, the Miller method, and the single photoelectron method. Temperature dependence was analyzed by measuring the breakdown voltage across a temperature range of 23°C to 43°C. Finally capacitance measurements were performed using a sinusoidal signal with constant amplitude and frequency, where determined using reference capacitance. Results The results from all three methods were consistent, yielding a breakdown voltage of 52.22±0.07 V for the MAPD-3NM-II and 68.08±0.10 V for the MPPC S12572-010P, within experimental uncertainties. The optimal operating voltage was determined as Ubr+4 V for the MAPD-3NM-II and Ubr+4.5 V for the MPPC S12572-010P. The temperature dependence of breakdown voltage was also investigated, revealing that the MAPD-3NM-II exhibited a lower temperature coefficient (51.32±0.44 mV/°C) compared to the MPPC S12572-010P (57.01±0.56 mV/°C). This indicates that the MAPD-3NM-II is more thermally stable. Capacitance measurements demonstrated that the MAPD-3NM-II exhibited significantly lower capacitance (155±12 pF) than the MPPC S12572-010P (294±26 pF). Conclusions This study provides a comparative analysis of two SiPMs with different pixel structures. The findings highlight the potential advantages of deeply burned pixel structures in terms of reduced capacitance and improved thermal stability. The lower capacitance of the MAPD-3NM-II suggests its suitability for large-area detector implementations. The results show that MAPD type photodiodes can be used in radiation detectors used in medicine and radiation monitoring systems.


  • Open Access

    Characterization of silicon photomultipliers with different structures

    by Sabuhi Nuruyev, Ramil Akbarov, Gadir Ahmadov, Daniyar Berikov, Aleksandr Nartov, Farid Ahmadov, Jalal Naghiyev, Sadigov, Rauf Sardarli, Michael Holik

    This study investigates the performance of two silicon photomultipliers (SiPMs) with distinct structures: the MAPD-3NM-II featuring a deeply burned pixel structure and the MPPC S12572-010P with a surface pixel structure. Fundamental parameters, including breakdown voltage, capacitance, gain, and the temperature dependence of breakdown voltage, were studied with methods like the Miller method, single photoelectron method, and current-voltage (I-V) and capacitance-voltage (C-V) measurements. Experimental results reveal the performance of these devices, particularly in terms of breakdown voltage determination and gain linearity under varying temperature. The temperature coefficients of the breakdown voltage were also determined to assess their thermal stability. The capacitance of the MAPD-3NM-II was measured at 155±12 pF, lower than 294±26 pF of the MPPC S12572-010P, which is about twice as much. This difference suggests promising opportunities for the development of SiPMs with larger active areas while maintaining low capacitance.

  • Open Access

    Study of Dynamic Time Over Threshold (DTOT) Method for Application in Spectroscopy Signal Analysis Toward a Low-Complexity Front-End Electronics With High Spectroscopy Resolution and Wide Energy Range

    by M. Holik, F. Ahmadov, A. Sadigov, O. Pavlas, O. Urban, G. Ahmadov, P. Kucera, F. Mamedov, M. Malich, R. Filgas

    Traditional approach of spectroscopy signals acquisition and analysis comprises digitization performed ideally by a high bit resolution and short sampling period flash ADC, followed by a subsequent digital processing requiring a high computational performance. However, some particular applications cannot implement that traditional approach while demanding comparable high spectroscopic performance due to hardware limitations mainly given by operational conditions, availability of qualified electronic components, power consumption limit, etc. The Dynamic Time Over Threshold (DTOT) conversion method-based processing of spectroscopy signals represents an undemanding alternative in contrary to that traditional approach. The detailed study of DTOT method-based processing was performed with the aim to maximize achievable performance via extension of the dynamic range allowing to process a wide span of input spectroscopy signals. The contribution also presents practical implementation of front-end electronics integrating an enhanced DTOT converter structure dedicated to a gamma detector (based on sensors of SiPM type) while test measurements with common reference radiation sources were performed to provide comparative results.


  • Open Access

    Neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IREN

    by S. Nuruyev, D. Berikov, R. Akbarov, G. Ahmadov, F. Ahmadov, A. Sadigov, M. Holik, J. Naghiyev, A. Madadzada, K. Udovichenko


  • Cross sections for the Cl35(n,α)P32 reaction in the 3.3–5.3 MeV neutron energy region

    by E. Sansarbayar, Yu. M. Gledenov, I. Chuprakov, G. Khuukhenkhuu, G. S. Ahmadov, L. Krupa, Guohui Zhang, Haoyu Jiang, Zengqi Cui, Yiwei Hu, et al.

    Cross sections for the Cl35(n,α)P32 reaction were systematically measured at incident neutron energies in the range of 3.3 to 5.3 MeV. The experiment was carried out on the Van de Graaff accelerator EG-5 at the Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Russia. Fast neutrons were produced in the reaction H2(d,n)3He. Alpha particles from the (n,α) reactions were detected using a gridded ionization chamber (GIC) in which various Cl35 samples (NaCl and BaCl2, on a tantalum backing) were placed back to back. The relative and absolute neutron fluxes were measured by two samples of U3238O8 (99.999%) inside the GIC. Data obtained in this measurement were compared with other experimental data of the existing library and theoretical calculations by the talys code. Presented data for the Cl35(n,α)P32 reaction should help to clarify discrepancies in the various published nuclear data.