Zhimin Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zhimin Hu has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Zhencen He
Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University 1 , Chengdu 610064
18 shared publications- Zhihao Yang
Sichuan University of Arts and Science
8 shared publications Tianluo Luo
Sichuan University
7 shared publications- Zhencen He
Sichuan University
6 shared publications Zhuohang He
Sichuan University
6 shared publicationsBaoren Wei
Institute of Modern Physics, Key Laboratory of Nuclear Physics and Ion-Beam Application (MOE), Fudan University, Shanghai 200433, People’s Republic of China
4 shared publications
Latest Publications
- 26 October 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (17)
Simulation of complex DNA damage enhancement and in vitro cell viability validation for Proton-CAT
Proton therapy has advanced rapidly because of its excellent dose conformity. However, its relatively low relative biological effectiveness may limit its therapeutic efficacy for certain tumors. To address this limitation, we previously proposed a nitrogen-targeting Proton-Carbon-Alpha-Therapy (Proton-CAT) enhancement method. In this work, we established a multiscale DNA damage simulation method. The method uses a pre-calculated DNA damage database generated by Geant4-DNA, coupling tissue-scale DNA damage simulations with microscopic DNA damage yields, supplemented by in vitro cell survival experiments, thereby further investigating the physical mechanisms and potential biological effects of Proton-CAT. The simulations' results show that 15N enrichment significantly enhances complex DNA damage induced by high-linear energy transfer particles within tumor regions. Under 30% 15N condition, compared with the tumor region without added 15N, α and 12C particle-induced DSB++ yield increased by 175.19% and 52.94%, respectively. Furthermore, in vitro cell experiments using 15N-glutamine (15N-Gln) as the 15N carrier indicated that high concentrations of 15N-Gln did not bring about significant cytotoxicity. Following 2 Gy irradiation, the cell viability in the 500 μg/ml 15N-Gln-treated group exhibited a net reduction of about 15.41% compared to the control group. The CCK-8 results showed a trend consistent with the simulation predictions, providing preliminary biological evidence for the Proton-CAT enhancement effect. This work provides a theoretical basis and a research framework for the further mechanistic and experimental development of Proton-CAT.
- 26 October 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (17)
Simulation of complex DNA damage enhancement and in vitro cell viability validation for Proton-CAT
Proton therapy has advanced rapidly because of its excellent dose conformity. However, its relatively low relative biological effectiveness may limit its therapeutic efficacy for certain tumors. To address this limitation, we previously proposed a nitrogen-targeting Proton-Carbon-Alpha-Therapy (Proton-CAT) enhancement method. In this work, we established a multiscale DNA damage simulation method. The method uses a pre-calculated DNA damage database generated by Geant4-DNA, coupling tissue-scale DNA damage simulations with microscopic DNA damage yields, supplemented by in vitro cell survival experiments, thereby further investigating the physical mechanisms and potential biological effects of Proton-CAT. The simulations' results show that 15N enrichment significantly enhances complex DNA damage induced by high-linear energy transfer particles within tumor regions. Under 30% 15N condition, compared with the tumor region without added 15N, α and 12C particle-induced DSB++ yield increased by 175.19% and 52.94%, respectively. Furthermore, in vitro cell experiments using 15N-glutamine (15N-Gln) as the 15N carrier indicated that high concentrations of 15N-Gln did not bring about significant cytotoxicity. Following 2 Gy irradiation, the cell viability in the 500 μg/ml 15N-Gln-treated group exhibited a net reduction of about 15.41% compared to the control group. The CCK-8 results showed a trend consistent with the simulation predictions, providing preliminary biological evidence for the Proton-CAT enhancement effect. This work provides a theoretical basis and a research framework for the further mechanistic and experimental development of Proton-CAT.
- 17 September 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 251
Comparative analysis of the D-T neutron anisotropy factor under uniform and non-uniform tritium distributions using BIXS-MLEM
- 17 September 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 251
Comparative analysis of the D-T neutron anisotropy factor under uniform and non-uniform tritium distributions using BIXS-MLEM
- 17 September 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (3)
Three-body fragmentation dynamics of triply charged 1,3-butadiene induced by 1-MeV/u C 4 + ions: Channels involving H 2 + formation
- 17 September 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (3)
Three-body fragmentation dynamics of triply charged 1,3-butadiene induced by 1-MeV/u C 4 + ions: Channels involving H 2 + formation
- 3 August 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (2)
Angular distribution of Auger electrons following dielectronic capture for hydrogenlike ions
- 3 August 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (2)
Angular distribution of Auger electrons following dielectronic capture for hydrogenlike ions
- 6 July 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 042001
A verification-oriented review of reaction-enhanced radiotherapy: linking nuclear data, transport modeling, and measurable observables
Reaction-enhanced radiotherapy (RER) aims to improve the therapeutic ratio of particle therapy by exploiting isotope-specific nuclear reactions that generate localized high-linear energy transfer secondary radiation. Absorbed dose remains the central metric for radiotherapy planning and evaluation; however, RER introduces additional verification requirements related to nuclear-reaction data, mixed-field transport, isotope delivery, and measurable secondary-field observables. This review frames RER as a verification-oriented physics problem built on three interdependent pillars: covariance-aware nuclear data, high-fidelity Monte Carlo transport, and reaction-specific secondary-field monitoring. Boron neutron capture therapy (BNCT) is treated as the clinically mature benchmark for RER, whereas PBCT and the emerging 15 N ( p , α ) 12 C-based proton-carbon-alpha therapy (Proton-CAT) are discussed as early-stage comparative cases. BNCT has the strongest clinical evidence base, while PBCT remains constrained by narrow resonances, low reaction yield, and limited observability. Proton-CAT provides a candidate 4.439 MeV prompt- γ observable whose verification value still requires detector-level validation and delivery/selectivity assessment. Overall, clinically credible RER requires coordinated progress in uncertainty-aware nuclear data, detector-integrated transport modeling, isotope delivery and tumor-to-normal biodistribution assessment, and high-sensitivity radiation monitoring for therapy verification.
- 6 July 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 042001
A verification-oriented review of reaction-enhanced radiotherapy: linking nuclear data, transport modeling, and measurable observables
Reaction-enhanced radiotherapy (RER) aims to improve the therapeutic ratio of particle therapy by exploiting isotope-specific nuclear reactions that generate localized high-linear energy transfer secondary radiation. Absorbed dose remains the central metric for radiotherapy planning and evaluation; however, RER introduces additional verification requirements related to nuclear-reaction data, mixed-field transport, isotope delivery, and measurable secondary-field observables. This review frames RER as a verification-oriented physics problem built on three interdependent pillars: covariance-aware nuclear data, high-fidelity Monte Carlo transport, and reaction-specific secondary-field monitoring. Boron neutron capture therapy (BNCT) is treated as the clinically mature benchmark for RER, whereas PBCT and the emerging 15 N ( p , α ) 12 C-based proton-carbon-alpha therapy (Proton-CAT) are discussed as early-stage comparative cases. BNCT has the strongest clinical evidence base, while PBCT remains constrained by narrow resonances, low reaction yield, and limited observability. Proton-CAT provides a candidate 4.439 MeV prompt- γ observable whose verification value still requires detector-level validation and delivery/selectivity assessment. Overall, clinically credible RER requires coordinated progress in uncertainty-aware nuclear data, detector-integrated transport modeling, isotope delivery and tumor-to-normal biodistribution assessment, and high-sensitivity radiation monitoring for therapy verification.
- Open Access
- 17 February 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (7)
Spread-out Bragg peak Monte Carlo simulation of proton therapy with 15N-targeted in situ generation of 12C ions and α-particles
Proton therapy has been criticized due to its relatively low biological effectiveness compared with heavy particle therapy, for example, 12C ion therapy. Recently, we proposed a new strategy for proton therapy to improve biological effectiveness, termed as nitrogen-targeting-Proton-Carbon-Alpha-Therapy (Proton-CAT). The previous work has demonstrated its feasibility to enhance the yield of high-linear energy transfer (LET) particles with a monoenergetic proton beam. To assess the feasibility of Proton-CAT for spread-out Bragg peak (SOBP) beams, we employed Monte Carlo simulations at both macroscopic and microscopic levels. For macroscopic calculations, an SOBP of 24–32 MeV protons with a modulation width of 3.0 mm was constructed and irradiated into a tissue-equivalent phantom with and without 15N material (10% and 30% 15N concentration). Dose deposition by protons, alpha particles, and 12C ions was scored along the beam path. For microscopic evaluation, a cell model was used to assess the damage inflicted by energetic particles (12C ions and α-particles). The results demonstrated the advantages of the Proton-CAT. Within the SOBP (0.6–0.82 cm depth), the average dose amplification for 12C ions exceeded 15.8% (10% 15N) and 38.5% (30% 15N), while for α-particles, it surpassed 68.5% (10% 15N) and 203.8% (30% 15N). Moreover, the energy deposition of 12C ions and α-particles in cell nucleus reached up to 3.50 keV μm−3 (10% and 30% 15N concentration). These findings support the hypothesis that the Proton-CAT has the feasibility to yield short-range, high-LET 12C ions and α-particles within the SOBP region.
- 17 February 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (7)
Open AccessSpread-out Bragg peak Monte Carlo simulation of proton therapy with 15N-targeted in situ generation of 12C ions and α-particles
Proton therapy has been criticized due to its relatively low biological effectiveness compared with heavy particle therapy, for example, 12C ion therapy. Recently, we proposed a new strategy for proton therapy to improve biological effectiveness, termed as nitrogen-targeting-Proton-Carbon-Alpha-Therapy (Proton-CAT). The previous work has demonstrated its feasibility to enhance the yield of high-linear energy transfer (LET) particles with a monoenergetic proton beam. To assess the feasibility of Proton-CAT for spread-out Bragg peak (SOBP) beams, we employed Monte Carlo simulations at both macroscopic and microscopic levels. For macroscopic calculations, an SOBP of 24–32 MeV protons with a modulation width of 3.0 mm was constructed and irradiated into a tissue-equivalent phantom with and without 15N material (10% and 30% 15N concentration). Dose deposition by protons, alpha particles, and 12C ions was scored along the beam path. For microscopic evaluation, a cell model was used to assess the damage inflicted by energetic particles (12C ions and α-particles). The results demonstrated the advantages of the Proton-CAT. Within the SOBP (0.6–0.82 cm depth), the average dose amplification for 12C ions exceeded 15.8% (10% 15N) and 38.5% (30% 15N), while for α-particles, it surpassed 68.5% (10% 15N) and 203.8% (30% 15N). Moreover, the energy deposition of 12C ions and α-particles in cell nucleus reached up to 3.50 keV μm−3 (10% and 30% 15N concentration). These findings support the hypothesis that the Proton-CAT has the feasibility to yield short-range, high-LET 12C ions and α-particles within the SOBP region.
- 29 January 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (1)
Polarization of x-rays emitted in radiative recombination into bare ions: Role of spin-flip transitions
- 29 January 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (1)
Polarization of x-rays emitted in radiative recombination into bare ions: Role of spin-flip transitions
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01029
Beam attenuation-optimized truncated-cone microchannels in titanium vacuum windows: Geant4 modeling of energy deposition and spectral broadening
For atmospheric irradiation experiments, precise particle beam flux attenuation is crucial for dose control, while conventional vacuum windows lack flux control functionality despite providing vacuum isolation. To facilitate atmospheric experiments, including in vitro cell irradiation, detector calibration, and broad-range irradiation studies, a truncated-cone microchannel collimator integrated into a vacuum window structure was designed to provide structural support for vacuum windows. In addition, it attenuates charged particle beam flux in research accelerators, such as electrostatic accelerators, cyclotrons, and synchrotrons. Monte Carlo simulations were employed to quantify energy deposition profiles and spectral distributions of protons, alpha particles, and C 6+ ions penetrating the composite structure. An average attenuation of 20% ± 5% was achieved across all tested beam species (protons, α -particles, and C 6+ ions) demonstrating the consistent performance of the geometry in reducing beam flux while preserving spectral integrity. These results highlighted the design's potential for applications requiring precise dose modulation and enhanced mechanical stability in beamline engineering.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01029
Beam attenuation-optimized truncated-cone microchannels in titanium vacuum windows: Geant4 modeling of energy deposition and spectral broadening
For atmospheric irradiation experiments, precise particle beam flux attenuation is crucial for dose control, while conventional vacuum windows lack flux control functionality despite providing vacuum isolation. To facilitate atmospheric experiments, including in vitro cell irradiation, detector calibration, and broad-range irradiation studies, a truncated-cone microchannel collimator integrated into a vacuum window structure was designed to provide structural support for vacuum windows. In addition, it attenuates charged particle beam flux in research accelerators, such as electrostatic accelerators, cyclotrons, and synchrotrons. Monte Carlo simulations were employed to quantify energy deposition profiles and spectral distributions of protons, alpha particles, and C 6+ ions penetrating the composite structure. An average attenuation of 20% ± 5% was achieved across all tested beam species (protons, α -particles, and C 6+ ions) demonstrating the consistent performance of the geometry in reducing beam flux while preserving spectral integrity. These results highlighted the design's potential for applications requiring precise dose modulation and enhanced mechanical stability in beamline engineering.
- 23 December 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (6)
Fragmentation of CO 2 2 + into C + + O + + O in collisions with 1 MeV/u C 4 + ions
- 23 December 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (6)
Fragmentation of CO 2 2 + into C + + O + + O in collisions with 1 MeV/u C 4 + ions