Abdulsamed Tabak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdulsamed Tabak has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Barış GÖKÇE
Necmettin Erbakan University
2 shared publications - Leyla Efe
NECMETTİN ERBAKAN ÜNİVERSİTESİ, FEN BİLİMLERİ ENSTİTÜSÜ
2 shared publications - Serhat Duman
Electrical Engineering, Engineering and Natural Sciences Faculty, Bandirma Onyedi Eylul University, Bandirma, Turkey
2 shared publications - Ümit Önen
NECMETTİN ERBAKAN ÜNİVERSİTESİ, MÜHENDİSLİK VE MİMARLIK FAKÜLTESİ
2 shared publications - Furkan Ilcin
Necmettin Erbakan University
1 shared publication - Hüseyin Oktay Erkol
Department of Electrical Engineering, Engineering and Natural Sciences Faculty, Bandirma Onyedi Eylul University, Balikesir, Türkiye
1 shared publication
Latest Publications
- 27 July 2026
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 24 (9) , 2437-2456
Coupled Longitudinal–Lateral Predictive Control for Path Tracking of Articulated Wheel Loaders
- 27 July 2026
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 24 (9) , 2437-2456
Coupled Longitudinal–Lateral Predictive Control for Path Tracking of Articulated Wheel Loaders
- 24 July 2026
- Published by Springer Nature in Cluster Computing
- Vol. 29 (9) , 555
Improved performance of short-term wind power forecasting system using a hybrid deep learning model with data pre-processing
- 24 July 2026
- Published by Springer Nature in Cluster Computing
- Vol. 29 (9) , 555
Improved performance of short-term wind power forecasting system using a hybrid deep learning model with data pre-processing
- Open Access
- 20 June 2026
- Published by Pamukkale University in Pamukkale University Journal of Engineering Sciences
- No. Advanced O
EFFECTS OF TRAINING-TEST SPLITTING RATIO ON THE PERFORMANCE OF LSTM-BASED BATTERY STATE OF CHARGE ESTIMATION MODEL: A COMPARATIVE STUDY
Context—Battery state of charge (SOC) estimation is considered a critical parameter in the management of electric vehicle (EV) batteries. Accurate and reliable SOC estimation directly contributes to the effective control of battery charging and discharging processes, optimization of energy management, and extension of battery life. Furthermore, precise SOC estimation demonstrates that EV operate more reliably, sustainably, and with higher efficiency. Therefore, SOC estimation is considered one of the fundamental components of battery management systems (BMS). Objective— In this study, a long short-term memory (LSTM) model, a deep learning-based approach, was chosen to perform SOC estimation. Method— The dataset used in the model implementation was divided into training and test datasets with different ratios to evaluate the model's learning and validation performance. To analyze the effect of training and test data ratios on model performance, four different scenarios were created in the first stage. In these scenarios, the training-test split ratios were determined as 60%-40%, 70%-30%, 80%-20%, and 90%-10%, respectively. In the second stage, these four different data splitting scenarios were applied separately to the LSTM model, and the model's estimation performance was examined in detail in each case. In the final stage, the obtained results were analyzed using various error metrics to quantitatively evaluate the model performance. In this context, mean absolute error (MAE), mean square error (MSE), root mean square error (RMSE), and coefficient of determination (R²) values were calculated and evaluated comparatively.Results— As a result of the analyses, it was clearly observed that even when the model parameters were kept constant, the training and test data ratios had a significant effect on the SOC estimation performance. According to the findings, the lowest error values were obtained when the training and test data ratio was set at 80%-20%. In this scenario, the MSE value was calculated as 1.3305%, the MAE value as 0.8003%, the RMSE value as 1.1535%, and the R² value as 93.53%. In contrast, the highest error values were determined to have occurred at a training-test ratio of 60%-40%. In this case, the MSE was found to be 4.9628%, MAE 1.7788%, RMSE 2.2277%, and R² 73.27%. Conclusion— Furthermore, the evaluations showed that as the training data ratio decreased, the model's training time also shortened. However, this negatively impacted the model's estimation accuracy and resulted in lower performance. These findings clearly demonstrate the crucial role of the amount of training data on model performance.
- 20 June 2026
- Published by Pamukkale University in Pamukkale University Journal of Engineering Sciences
- No. Advanced O
Open AccessEFFECTS OF TRAINING-TEST SPLITTING RATIO ON THE PERFORMANCE OF LSTM-BASED BATTERY STATE OF CHARGE ESTIMATION MODEL: A COMPARATIVE STUDY
Context—Battery state of charge (SOC) estimation is considered a critical parameter in the management of electric vehicle (EV) batteries. Accurate and reliable SOC estimation directly contributes to the effective control of battery charging and discharging processes, optimization of energy management, and extension of battery life. Furthermore, precise SOC estimation demonstrates that EV operate more reliably, sustainably, and with higher efficiency. Therefore, SOC estimation is considered one of the fundamental components of battery management systems (BMS). Objective— In this study, a long short-term memory (LSTM) model, a deep learning-based approach, was chosen to perform SOC estimation. Method— The dataset used in the model implementation was divided into training and test datasets with different ratios to evaluate the model's learning and validation performance. To analyze the effect of training and test data ratios on model performance, four different scenarios were created in the first stage. In these scenarios, the training-test split ratios were determined as 60%-40%, 70%-30%, 80%-20%, and 90%-10%, respectively. In the second stage, these four different data splitting scenarios were applied separately to the LSTM model, and the model's estimation performance was examined in detail in each case. In the final stage, the obtained results were analyzed using various error metrics to quantitatively evaluate the model performance. In this context, mean absolute error (MAE), mean square error (MSE), root mean square error (RMSE), and coefficient of determination (R²) values were calculated and evaluated comparatively.Results— As a result of the analyses, it was clearly observed that even when the model parameters were kept constant, the training and test data ratios had a significant effect on the SOC estimation performance. According to the findings, the lowest error values were obtained when the training and test data ratio was set at 80%-20%. In this scenario, the MSE value was calculated as 1.3305%, the MAE value as 0.8003%, the RMSE value as 1.1535%, and the R² value as 93.53%. In contrast, the highest error values were determined to have occurred at a training-test ratio of 60%-40%. In this case, the MSE was found to be 4.9628%, MAE 1.7788%, RMSE 2.2277%, and R² 73.27%. Conclusion— Furthermore, the evaluations showed that as the training data ratio decreased, the model's training time also shortened. However, this negatively impacted the model's estimation accuracy and resulted in lower performance. These findings clearly demonstrate the crucial role of the amount of training data on model performance.
- 12 May 2026
- Published by Taylor & Francis in International Journal of Systems Science
- p. 1-22
Robust hybrid T1/IT2 fuzzy PIDD 2 controllers for AVR systems under parameter uncertainties and challenging operating conditions
1. Electrical power systems have become an indispensable part of modern life, encompassing a broad process that extends from generation and transmission to distribution and final consumption. The c...
- 12 May 2026
- Published by Taylor & Francis in International Journal of Systems Science
- p. 1-22
Robust hybrid T1/IT2 fuzzy PIDD 2 controllers for AVR systems under parameter uncertainties and challenging operating conditions
1. Electrical power systems have become an indispensable part of modern life, encompassing a broad process that extends from generation and transmission to distribution and final consumption. The c...
- 3 February 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 255
State estimation for electric vehicles with deep learning- a survey
- 3 February 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 255
State estimation for electric vehicles with deep learning- a survey
- Open Access
- 11 November 2024
- Published by MDPI AG in Fractal and Fractional
- Vol. 8 (11) , 654
Modified and Improved TID Controller for Automatic Voltage Regulator Systems
This paper proposes a fractional order integral-derivative plus second-order derivative with low-pass filters and a tilt controller called IλDND2N2-T to improve the control performance of an automatic voltage regulator (AVR). In this study, equilibrium optimisation (EO), multiverse optimisation (MVO), and particle swarm optimisation (PSO) algorithms are used to optimise the parameters of the proposed controller and statistical tests are performed with the data obtained from the application of these three algorithms to the AVR problem. Afterwards, the performance of the IλDND2N2-T controller is demonstrated by comparing the transient responses with the results obtained in recently published papers. In addition, extra disturbances such as frequency deviation, load variation, and short circuit faults in the generator are applied to the AVR system. The proposed controller has outperformed the compared controller against these disturbances. Finally, a robustness test is performed in terms of deterioration in the system parameters. The results show that the IλDND2N2-T controller outperforms the compared controllers under all conditions and exhibits a robust effect on the perturbed system parameters.
- 11 November 2024
- Published by MDPI AG in Fractal and Fractional
- Vol. 8 (11) , 654
Open AccessModified and Improved TID Controller for Automatic Voltage Regulator Systems
This paper proposes a fractional order integral-derivative plus second-order derivative with low-pass filters and a tilt controller called IλDND2N2-T to improve the control performance of an automatic voltage regulator (AVR). In this study, equilibrium optimisation (EO), multiverse optimisation (MVO), and particle swarm optimisation (PSO) algorithms are used to optimise the parameters of the proposed controller and statistical tests are performed with the data obtained from the application of these three algorithms to the AVR problem. Afterwards, the performance of the IλDND2N2-T controller is demonstrated by comparing the transient responses with the results obtained in recently published papers. In addition, extra disturbances such as frequency deviation, load variation, and short circuit faults in the generator are applied to the AVR system. The proposed controller has outperformed the compared controller against these disturbances. Finally, a robustness test is performed in terms of deterioration in the system parameters. The results show that the IλDND2N2-T controller outperforms the compared controllers under all conditions and exhibits a robust effect on the perturbed system parameters.
- Open Access
- 3 August 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (7) , 1269-1291
Maiden application of TID μ 1 ND μ 2 controller for effective load frequency control of non‐linear two‐area power system
In the paper, the maiden application of Tilted Integral Fractional Derivative with Filter plus Fractional Derivative controller (), called TIFDNFD controller, is proposed to achieve load frequency control (LFC) of two area‐multi source power system. In the study, both areas include thermal power, hydropower, and gas turbine power systems. In this study, generation rate constraint and governor dead‐band are integrated into the power system to evaluate the performance of the controller in a non‐linear environment. The wild horse optimizer (WHO) is used for controller parameter tuning in the LFC problem for the first time. The performance of the proposed controller is demonstrated by comparing it with the recently published studies including different controllers. In this study, to obtain more realistic results, solar photovoltaic (PV) power, wind power, and load demand with stochastic form have been added to the power system. In addition, the dynamic effect of the hydrogen storage system, consisting of an electrolyser and a fuel cell, is considered a grid supporter. The superiority of the WHO algorithm in optimization has been verified by comparing it with three optimization algorithms recently proposed. Finally, the resilience and robustness of the power system are evaluated in perturbed system parameters.
- 3 August 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (7) , 1269-1291
Open AccessMaiden application of TID μ 1 ND μ 2 controller for effective load frequency control of non‐linear two‐area power system
In the paper, the maiden application of Tilted Integral Fractional Derivative with Filter plus Fractional Derivative controller (), called TIFDNFD controller, is proposed to achieve load frequency control (LFC) of two area‐multi source power system. In the study, both areas include thermal power, hydropower, and gas turbine power systems. In this study, generation rate constraint and governor dead‐band are integrated into the power system to evaluate the performance of the controller in a non‐linear environment. The wild horse optimizer (WHO) is used for controller parameter tuning in the LFC problem for the first time. The performance of the proposed controller is demonstrated by comparing it with the recently published studies including different controllers. In this study, to obtain more realistic results, solar photovoltaic (PV) power, wind power, and load demand with stochastic form have been added to the power system. In addition, the dynamic effect of the hydrogen storage system, consisting of an electrolyser and a fuel cell, is considered a grid supporter. The superiority of the WHO algorithm in optimization has been verified by comparing it with three optimization algorithms recently proposed. Finally, the resilience and robustness of the power system are evaluated in perturbed system parameters.
- Open Access
- 27 July 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (15) , 11640
Novel TIλDND2N2 Controller Application with Equilibrium Optimizer for Automatic Voltage Regulator
Sustainability is important in voltage regulation control in grids and must be done successfully. In this paper, a novel tilt-fractional order integral-derivative with a second order derivative and low-pass filters controller, referred to as TIλDND2N2 controller, is proposed to enhance the control performance of an automatic voltage regulator (AVR). In this article, the equilibrium optimizer (EO) algorithm is used to optimally determine the eight parameters of the proposed controller. In this study, a function consisting of time domain specifications is used as the objective function. To evaluate the performance of the proposed controller, it is compared with the proportional-integral-derivative (PID), fractional order PID (FOPID), PID accelerator (PIDA), PID plus second order derivative (PIDD2), and hybrid controllers used in previous studies. Then, Bode analysis is performed to determine the achievement of the proposed controller in the frequency domain. Finally, the robustness test is realized to assess the response of the proposed controller against the deterioration of the system parameters. As a result, the proposed controller demonstrates outstanding control performance compared to studies in terms of settling time, rise time and overshoot. The proposed controller shows superior performance not only in frequency domain analysis but also in perturbed system parameters.
- 27 July 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (15) , 11640
Open AccessNovel TIλDND2N2 Controller Application with Equilibrium Optimizer for Automatic Voltage Regulator
Sustainability is important in voltage regulation control in grids and must be done successfully. In this paper, a novel tilt-fractional order integral-derivative with a second order derivative and low-pass filters controller, referred to as TIλDND2N2 controller, is proposed to enhance the control performance of an automatic voltage regulator (AVR). In this article, the equilibrium optimizer (EO) algorithm is used to optimally determine the eight parameters of the proposed controller. In this study, a function consisting of time domain specifications is used as the objective function. To evaluate the performance of the proposed controller, it is compared with the proportional-integral-derivative (PID), fractional order PID (FOPID), PID accelerator (PIDA), PID plus second order derivative (PIDD2), and hybrid controllers used in previous studies. Then, Bode analysis is performed to determine the achievement of the proposed controller in the frequency domain. Finally, the robustness test is realized to assess the response of the proposed controller against the deterioration of the system parameters. As a result, the proposed controller demonstrates outstanding control performance compared to studies in terms of settling time, rise time and overshoot. The proposed controller shows superior performance not only in frequency domain analysis but also in perturbed system parameters.
- 9 July 2022
- Published by Elsevier in Applied Soft Computing
- Vol. 126
An effective method based on simulated annealing for automatic generation control of power systems
- 9 July 2022
- Published by Elsevier in Applied Soft Computing
- Vol. 126
An effective method based on simulated annealing for automatic generation control of power systems
- 20 June 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 47 (11) , 14757-14788
Levy Flight and Fitness Distance Balance-Based Coyote Optimization Algorithm for Effective Automatic Generation Control of PV-Based Multi-Area Power Systems
- 20 June 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 47 (11) , 14757-14788
Levy Flight and Fitness Distance Balance-Based Coyote Optimization Algorithm for Effective Automatic Generation Control of PV-Based Multi-Area Power Systems