Zeping Huang
Zeping Huang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Jianhui Fan
Department of Obstetrics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, People’s Republic of China
2 shared publicationsPing Li
Department of Obstetrics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, People’s Republic of China
2 shared publications- Rongqin Zheng
The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
2 shared publications - Ting Zhang
Department of Medical Ultrasound, Guangdong Provincial Key Laboratory of Diabetology & Guangzhou Municipal Key Laboratory of Mechanistic and Translational Obesity Research, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
2 shared publications - Cong Wang
Renmin University of China
1 shared publication - Enze Qu
Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510630, China
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Taylor & Francis in International Journal of Women's Health
- Vol. ume 18, 1-13
Cervical Ultrasound Assessment vs Bishop Score in Predicting Labor Induction Outcomes Among Nulliparous Women
Objective: Induction of labor (IOL) failure increases the risk of maternal and neonatal complications. The traditional Bishop score (BS) for cervical assessment is limited by subjectivity and inter - observer variability. This study aimed to evaluate cervical status via ultrasound examination (UE) as an alternative to vaginal examination (VE), and compare its predictive performance for IOL outcomes with the BS. Methods: In this prospective observational study, 106 nulliparous women with singleton pregnancy requiring IOL were enrolled from January 2024 to August 2025. Of these participants, 83 had successful IOL and 75 achieved vaginal delivery (VD). Cervical length (CL), posterior cervical angle (PCA), angle of progression (AoP), and cervical shear wave elastography (SWE) were measured, and compared with the conventional BS. The primary outcomes were successful IOL and VD. Multivariate logistic analysis was performed to identify independent influencing factors for the two outcomes, and ROC curve analysis was used to evaluate their predictive efficacy. Results: Significant differences were observed in ultrasound parameters between groups stratified by both outcomes (P < 0.05), whereas BS indicators showed no significant differences (all P > 0.05). Multivariate logistic analysis showed that only cervical SWE was independently correlated with successful IOL and VD (P < 0.05), with superior predictive power compared with BS (AUC of 0.78 vs 0.53 for successful IOL and 0.78 vs 0.56 for VD). Significant differences in pain perception existed between VE and UE (χ2 = 212.00, P < 0.001). All participants suffered moderate to severe pain after VE, while nearly 85% felt pain - free and none had moderate or severe pain after UE. Conclusion: Ultrasound outperformed BS in evaluating cervical morphology owing to its objectivity, repeatability, and visualization capability in routine practice, and also yielded a better patient experience before IOL. Cervical stiffness appears to be an important influencing factor for IOL success, and SWE shows potential as a promising predictive approach for IOL outcome.
- 1 June 2026
- Published by Taylor & Francis in International Journal of Women's Health
- Vol. ume 18, 1-13
Open AccessCervical Ultrasound Assessment vs Bishop Score in Predicting Labor Induction Outcomes Among Nulliparous Women
Objective: Induction of labor (IOL) failure increases the risk of maternal and neonatal complications. The traditional Bishop score (BS) for cervical assessment is limited by subjectivity and inter - observer variability. This study aimed to evaluate cervical status via ultrasound examination (UE) as an alternative to vaginal examination (VE), and compare its predictive performance for IOL outcomes with the BS. Methods: In this prospective observational study, 106 nulliparous women with singleton pregnancy requiring IOL were enrolled from January 2024 to August 2025. Of these participants, 83 had successful IOL and 75 achieved vaginal delivery (VD). Cervical length (CL), posterior cervical angle (PCA), angle of progression (AoP), and cervical shear wave elastography (SWE) were measured, and compared with the conventional BS. The primary outcomes were successful IOL and VD. Multivariate logistic analysis was performed to identify independent influencing factors for the two outcomes, and ROC curve analysis was used to evaluate their predictive efficacy. Results: Significant differences were observed in ultrasound parameters between groups stratified by both outcomes (P < 0.05), whereas BS indicators showed no significant differences (all P > 0.05). Multivariate logistic analysis showed that only cervical SWE was independently correlated with successful IOL and VD (P < 0.05), with superior predictive power compared with BS (AUC of 0.78 vs 0.53 for successful IOL and 0.78 vs 0.56 for VD). Significant differences in pain perception existed between VE and UE (χ2 = 212.00, P < 0.001). All participants suffered moderate to severe pain after VE, while nearly 85% felt pain - free and none had moderate or severe pain after UE. Conclusion: Ultrasound outperformed BS in evaluating cervical morphology owing to its objectivity, repeatability, and visualization capability in routine practice, and also yielded a better patient experience before IOL. Cervical stiffness appears to be an important influencing factor for IOL success, and SWE shows potential as a promising predictive approach for IOL outcome.
- 21 August 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (4) , e70099
Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study
Purpose: This study aims to assess the ability of a 5G‐based telerobotic system to generate required images of diagnostic quality in multi‐organ US examinations.Materials and Methods: This prospective study involved participants in Shenzhen and Tibet, which are 106 and 4000 km, respectively, from the tele‐radiologist's hospital. Participants underwent telerobotic US examinations from September 2020 to March 2021. A total of 127 participants were enrolled. The required image quality was evaluated by the required image adequacy, image quality, the observer reliability and the consistency of the conventional US. The safety assessments were assessed by complications and questionnaires.Results: A total of 1790/2032 (88.1%) required images were considered adequate, and 167/2032 (8.2%) were considered adequate with some reservations. The mean image quality score was 2.83 ± 0.47 on a three‐point Likert scale and did not differ between the districts or sexes. Telerobotic US detected 15 out of 18 abnormalities (83.3%) in 10 patients who underwent both telerobotic US and conventional US. There was good consistency between the two methods (k = 0.7–1.0). Furthermore, nearly 86.0% of patients accepted and would be willing to undergo another telerobotic US examination in the future. Teleradiologists accepted almost all US examinations as adequate for diagnosis and were satisfied with them.Conclusions: The 5G‐based telerobotic US(MGIUS‐R3) can acquire required images with adequacy and quality in multiple organ examination procedures, with high safety and customer satisfaction in this limited group of patients. Further studies with larger samples and more centres are needed to validate this potential new technology.
- 21 August 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (4) , e70099
Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study
Purpose: This study aims to assess the ability of a 5G‐based telerobotic system to generate required images of diagnostic quality in multi‐organ US examinations.Materials and Methods: This prospective study involved participants in Shenzhen and Tibet, which are 106 and 4000 km, respectively, from the tele‐radiologist's hospital. Participants underwent telerobotic US examinations from September 2020 to March 2021. A total of 127 participants were enrolled. The required image quality was evaluated by the required image adequacy, image quality, the observer reliability and the consistency of the conventional US. The safety assessments were assessed by complications and questionnaires.Results: A total of 1790/2032 (88.1%) required images were considered adequate, and 167/2032 (8.2%) were considered adequate with some reservations. The mean image quality score was 2.83 ± 0.47 on a three‐point Likert scale and did not differ between the districts or sexes. Telerobotic US detected 15 out of 18 abnormalities (83.3%) in 10 patients who underwent both telerobotic US and conventional US. There was good consistency between the two methods (k = 0.7–1.0). Furthermore, nearly 86.0% of patients accepted and would be willing to undergo another telerobotic US examination in the future. Teleradiologists accepted almost all US examinations as adequate for diagnosis and were satisfied with them.Conclusions: The 5G‐based telerobotic US(MGIUS‐R3) can acquire required images with adequacy and quality in multiple organ examination procedures, with high safety and customer satisfaction in this limited group of patients. Further studies with larger samples and more centres are needed to validate this potential new technology.
- Open Access
- 20 November 2022
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 22 (1) , 1-5
Management of breech presentation with a large pelvic hydatid cyst in late pregnancy in Tibet: a case report
Background: Hydatid cystic disease (HCD) is primarily a disease of sheep and cattle. Human beings are accidental hosts. It is prevalent in the Tibet Autonomous Region (TAR) of China. In pregnancy, it can cause many complications. Case presentation: We present a multigravida with breech presentation at 37 weeks of pregnancy in whom a large pelvic hydatid cyst and multiple hepatic hydatids were diagnosed by ultrasonography. The large pelvic hydatid cyst was drained through the posterior fornix under the guidance of ultrasound, and an external cephalic version was performed. A healthy baby was delivered vaginally with head presentation at term. Conclusion: HCD during pregnancy presents with management difficulty. It is important to formulate individualized treatment plans according to the actual situation of the patient and the local level of treatment.
- 20 November 2022
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 22 (1) , 1-5
Open AccessManagement of breech presentation with a large pelvic hydatid cyst in late pregnancy in Tibet: a case report
Background: Hydatid cystic disease (HCD) is primarily a disease of sheep and cattle. Human beings are accidental hosts. It is prevalent in the Tibet Autonomous Region (TAR) of China. In pregnancy, it can cause many complications. Case presentation: We present a multigravida with breech presentation at 37 weeks of pregnancy in whom a large pelvic hydatid cyst and multiple hepatic hydatids were diagnosed by ultrasonography. The large pelvic hydatid cyst was drained through the posterior fornix under the guidance of ultrasound, and an external cephalic version was performed. A healthy baby was delivered vaginally with head presentation at term. Conclusion: HCD during pregnancy presents with management difficulty. It is important to formulate individualized treatment plans according to the actual situation of the patient and the local level of treatment.
- Open Access
- 24 March 2022
- Published by Elsevier in European Journal of Radiology Open
- Vol. 9, 100412
Deep learning-based pelvic levator hiatus segmentation from ultrasound images
- 24 March 2022
- Published by Elsevier in European Journal of Radiology Open
- Vol. 9, 100412
Open AccessDeep learning-based pelvic levator hiatus segmentation from ultrasound images
- 1 November 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 301 (2) , 350-359
APS (Age, Platelets, 2D Shear-Wave Elastography) Score Predicts Hepatocellular Carcinoma in Chronic Hepatitis B
A hepatocellular carcinoma (HCC) prediction score constructed from age, platelet count, and liver stiffness measurement at two-dimensional shear-wave elastography, or APS score, higher than 60 is p... Background Two-dimensional (2D) shear-wave elastography (SWE) has been considered to be useful in predicting hepatocellular carcinoma (HCC) development in patients with chronic hepatitis B (CHB). P...
- 1 November 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 301 (2) , 350-359
APS (Age, Platelets, 2D Shear-Wave Elastography) Score Predicts Hepatocellular Carcinoma in Chronic Hepatitis B
A hepatocellular carcinoma (HCC) prediction score constructed from age, platelet count, and liver stiffness measurement at two-dimensional shear-wave elastography, or APS score, higher than 60 is p... Background Two-dimensional (2D) shear-wave elastography (SWE) has been considered to be useful in predicting hepatocellular carcinoma (HCC) development in patients with chronic hepatitis B (CHB). P...
- 29 October 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (5) , 3207-3215
How does liver steatosis affect diagnostic performance of 2D-SWE.SSI: assessment from aspects of steatosis degree and pathological types
Objective Two-dimensional shear wave elastography performed by SurperSonics (2D-SWE.SSI) performs well in evaluating liver fibrosis. Steatosis is one of confounding factors which might decrease accuracy, and its effect on 2D-SWE.SSI is still controversial. Our purpose is to evaluate the diagnostic performance of 2D-SWE.SSI affected by different steatosis stages and pathological types in chronic hepatitis B (CHB) patients. Methods 2D-SWE.SSI was performed on 1306 CHB patients. All patients were divided into mild steatosis, moderate to severe steatosis, and non-steatosis groups. Subgroup analysis was performed according to pathological type. Liver biopsy was reference standard. Propensity score matching was performed to adjust for differences in patient characteristics. The median values of different steatosis group were compared by non-parametric tests before and after propensity score matching. The area under the receiver operating characteristic curve (AUC) was analyzed to assess the diagnostic performance in different steatosis groups. Results The median values were not significantly different in different steatosis degrees expected in F0–1 patients. The AUC of 2D-SWE.SSI was not affected by different stages of liver steatosis for cirrhosis (= F4) (0.896, 0.853, 0.929, p = 0.34). The high AUCs (0.847, 0.856) were achieved in the non-steatosis and mild steatosis groups, and all were significantly higher than those of the moderate to severe steatosis group for ≥ F2. Moreover, the panacinar type had the best AUC (0.980 for F4 and 0.930 for ≥ F2). Conclusion In conclusion, moderate to severe steatosis affects 2D-SWE.SSI in CHB patients. These patients had high LSM values in patients with F0–1 and lower accuracy in ≥ F2. Patients with panacinar steatosis have the highest overall diagnostic performance. Key Points • 2D-SWE.SSI was widely used in evaluating liver fibrosis and it has many confounding factors. Steatosis is one of the confounding factors and its effect on 2D-SWE.SSI was controversial. • Our study based on 1306 CHB patients with liver biopsy found that 2D-SWE.SSI might be affected by moderate to severe liver steatosis in diagnostically significant fibrosis (≥ F2) of CHB patients. • Patients with steatosis of the panacinar type have the highest overall diagnostic performance.
- 29 October 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (5) , 3207-3215
How does liver steatosis affect diagnostic performance of 2D-SWE.SSI: assessment from aspects of steatosis degree and pathological types
Objective Two-dimensional shear wave elastography performed by SurperSonics (2D-SWE.SSI) performs well in evaluating liver fibrosis. Steatosis is one of confounding factors which might decrease accuracy, and its effect on 2D-SWE.SSI is still controversial. Our purpose is to evaluate the diagnostic performance of 2D-SWE.SSI affected by different steatosis stages and pathological types in chronic hepatitis B (CHB) patients. Methods 2D-SWE.SSI was performed on 1306 CHB patients. All patients were divided into mild steatosis, moderate to severe steatosis, and non-steatosis groups. Subgroup analysis was performed according to pathological type. Liver biopsy was reference standard. Propensity score matching was performed to adjust for differences in patient characteristics. The median values of different steatosis group were compared by non-parametric tests before and after propensity score matching. The area under the receiver operating characteristic curve (AUC) was analyzed to assess the diagnostic performance in different steatosis groups. Results The median values were not significantly different in different steatosis degrees expected in F0–1 patients. The AUC of 2D-SWE.SSI was not affected by different stages of liver steatosis for cirrhosis (= F4) (0.896, 0.853, 0.929, p = 0.34). The high AUCs (0.847, 0.856) were achieved in the non-steatosis and mild steatosis groups, and all were significantly higher than those of the moderate to severe steatosis group for ≥ F2. Moreover, the panacinar type had the best AUC (0.980 for F4 and 0.930 for ≥ F2). Conclusion In conclusion, moderate to severe steatosis affects 2D-SWE.SSI in CHB patients. These patients had high LSM values in patients with F0–1 and lower accuracy in ≥ F2. Patients with panacinar steatosis have the highest overall diagnostic performance. Key Points • 2D-SWE.SSI was widely used in evaluating liver fibrosis and it has many confounding factors. Steatosis is one of the confounding factors and its effect on 2D-SWE.SSI was controversial. • Our study based on 1306 CHB patients with liver biopsy found that 2D-SWE.SSI might be affected by moderate to severe liver steatosis in diagnostically significant fibrosis (≥ F2) of CHB patients. • Patients with steatosis of the panacinar type have the highest overall diagnostic performance.
- 15 June 2020
- Published by Springer Nature in Nano Research
- Vol. 13 (8) , 2233-2238
Investigating molecular orbitals with submolecular precision on pristine sites and single atomic vacancies of monolayer h-BN
- 15 June 2020
- Published by Springer Nature in Nano Research
- Vol. 13 (8) , 2233-2238
Investigating molecular orbitals with submolecular precision on pristine sites and single atomic vacancies of monolayer h-BN