Theresa Urban
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Theresa Urban has a total of 294 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Brunet
Department of Mechanical Engineering, Faculty of Engineering Sciences, University College London, London, United Kingdom, WC1E 7JE
16 shared publications - Peter David Lee
Department of Mechanical Engineering, University College London, London, UK
16 shared publications - Hector Dejea
European Synchrotron Radiation Facility, Grenoble, France
15 shared publications - Franz Pfeiffer
Department of Diagnostic and Interventional Radiology, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany
14 shared publications - Paul Tafforeau
European Synchrotron Radiation Facility
13 shared publications - Claire L. Walsh
University College London
12 shared publications
Latest Publications
- Open Access
Cross-species structure–mechanics prediction in the intervertebral disc
Despite long-standing uncertainty regarding the suitability of animal intervertebral disc (IVD) models for the study of human IVD pathophysiology, few cross-species studies have integrated hierarchical structure with mechanical function. In this study, we present a multiscale structure–mechanics framework combining synchrotron computed tomography (sCT), fibre tracing, digital volume correlation (DVC) with structure-based mechanical inference and finite-element modelling. Rat, mini-pig and human IVDs (n = 3/species) were imaged by sCT, with rat and mini-pig discs additionally subjected to in situ uniaxial compression and DVC. A Structure Index (SI), integrating local structural anisotropy and fibre orientation, was developed to regionally pinpoint the location of mechanically vulnerable regions. Cross-species comparison showed scale-dependent structural conservation: gross disc and lamellar organisation retained common regional features, whereas fibre-bundle architecture exhibited greater species- and regional divergence. Despite these differences, lower SI was consistently associated with elevated deformation in rat and mini-pig discs across multiple strain measures. Structure–strain inverse correlations became tighter within progressively higher-strain domains, reaching Spearman ρ values of approximately −0.5 to −0.7 for several strain components. Synthetic fibre phantoms confirmed that SI reflects a coupling of fibre orientation and organisation, with additional sensitivity to fibre number in poorly organised configurations. In human discs with varying degrees of degeneration, SI revealed spatial heterogeneity and redistribution of structurally vulnerable regions. Fibril-informed homogenisation provided anisotropic material properties for organ-scale finite-element modelling that independently supported SI-based predictions. Overall, these findings establish a cross-species framework linking hierarchical collagen architecture to mechanical vulnerability and provide a basis for non-invasive, structure-driven biomechanical assessment of human IVD degeneration and mechanical risk.
Open AccessCross-species structure–mechanics prediction in the intervertebral disc
Despite long-standing uncertainty regarding the suitability of animal intervertebral disc (IVD) models for the study of human IVD pathophysiology, few cross-species studies have integrated hierarchical structure with mechanical function. In this study, we present a multiscale structure–mechanics framework combining synchrotron computed tomography (sCT), fibre tracing, digital volume correlation (DVC) with structure-based mechanical inference and finite-element modelling. Rat, mini-pig and human IVDs (n = 3/species) were imaged by sCT, with rat and mini-pig discs additionally subjected to in situ uniaxial compression and DVC. A Structure Index (SI), integrating local structural anisotropy and fibre orientation, was developed to regionally pinpoint the location of mechanically vulnerable regions. Cross-species comparison showed scale-dependent structural conservation: gross disc and lamellar organisation retained common regional features, whereas fibre-bundle architecture exhibited greater species- and regional divergence. Despite these differences, lower SI was consistently associated with elevated deformation in rat and mini-pig discs across multiple strain measures. Structure–strain inverse correlations became tighter within progressively higher-strain domains, reaching Spearman ρ values of approximately −0.5 to −0.7 for several strain components. Synthetic fibre phantoms confirmed that SI reflects a coupling of fibre orientation and organisation, with additional sensitivity to fibre number in poorly organised configurations. In human discs with varying degrees of degeneration, SI revealed spatial heterogeneity and redistribution of structurally vulnerable regions. Fibril-informed homogenisation provided anisotropic material properties for organ-scale finite-element modelling that independently supported SI-based predictions. Overall, these findings establish a cross-species framework linking hierarchical collagen architecture to mechanical vulnerability and provide a basis for non-invasive, structure-driven biomechanical assessment of human IVD degeneration and mechanical risk.
- Open Access
Revealing multiscale architecture of the intact human spine using hierarchical phase-contrast tomography
Background: CT and MRI provide detailed clinical assessment of the human spine; however, their millimeter-scale spatial resolution limits direct visualization of tissue microarchitecture and interfaces. Hierarchical phase-contrast tomography (HiP-CT) enables ex vivo non-destructive, micron-resolution imaging of intact human organs without exogenous contrast agents, extending anatomical assessment to spatial scales inaccessible to conventional clinical imaging. Purpose: To evaluate the capability of HiP-CT to visualize macro- to microanatomy of an intact adult human spine ex vivo . Materials and Methods: An intact spine (C1-L5) from a 62-year-old male donor without known skeletal disease was formalin-fixed and imaged by HiP-CT at the European Synchrotron. Whole-spine imaging was performed using 16.26 µm isotropic voxels, with selected regions of interest imaged using 2.2 µm voxels. Ex vivo MRI was performed for anatomical comparison. Three-dimensional segmentation and quantitative analyses included intervertebral disc (IVD) grading, annulus fibrosus fiber tracing, and vertebral trabecular micro-morphometry. Results: HiP-CT enabled high spatial-resolution, multiscale imaging of the intact human spine, simultaneously visualizing vertebral bone and endplate, IVDs, spinal cord and meninges, nerve roots and ganglia, vasculature, ligaments, and musculature. Three-dimensional segmentation and virtual sectioning mapped neurovascular anatomy and vertebral vascular supply, without exogenous contrast enhancement, while preserving their relationships with surrounding tissues. Whole-spine images enabled quantitative analysis of annulus fibrosus fiber organization and vertebral trabecular microarchitecture, permitting the detection of focal posterolateral fiber disruption at the L4-L5 IVD and regional differences in trabecular architecture between cervical and lumbar vertebral bodies. Local tomography resolved annulus fibrosus lamellae, vertebral endplate Haversian systems, and facet joint hyaline cartilage at micron resolution. Conclusions: HiP-CT enables non-destructive, multiscale three-dimensional imaging of the intact human spine while preserving tissue relationships across spatial scales and tissue boundaries. HiP-CT images could provide an ex vivo microanatomical reference for future correlation with clinical imaging investigations of spinal disease and in the discovery and validation of imaging biomarkers. Key results: Synchrotron-based hierarchical phase-contrast tomography enables non-destructive, multiscale three-dimensional imaging of an intact adult human spine using 16.26 µm isotropic voxels, resolving both mineralized and non-mineralized tissue. Local tomography using 2.2 µm isotropic voxels reveals additional microstructural detail without exogenous contrast agents or sectioning. Whole-spine imaging enables quantitative characterization of intervertebral disc fiber architecture and vertebral trabecular morphometry, alongside visualization of neurovascular anatomy while preserving spatial relationships across the intact specimen. Summary statement: Hierarchical phase-contrast tomography enables non-destructive multiscale imaging of the intact human spine, resolving microarchitecture across tissues and interfaces and providing a basis for bridging clinical imaging with underlying three-dimensional microanatomy.
Open AccessRevealing multiscale architecture of the intact human spine using hierarchical phase-contrast tomography
Background: CT and MRI provide detailed clinical assessment of the human spine; however, their millimeter-scale spatial resolution limits direct visualization of tissue microarchitecture and interfaces. Hierarchical phase-contrast tomography (HiP-CT) enables ex vivo non-destructive, micron-resolution imaging of intact human organs without exogenous contrast agents, extending anatomical assessment to spatial scales inaccessible to conventional clinical imaging. Purpose: To evaluate the capability of HiP-CT to visualize macro- to microanatomy of an intact adult human spine ex vivo . Materials and Methods: An intact spine (C1-L5) from a 62-year-old male donor without known skeletal disease was formalin-fixed and imaged by HiP-CT at the European Synchrotron. Whole-spine imaging was performed using 16.26 µm isotropic voxels, with selected regions of interest imaged using 2.2 µm voxels. Ex vivo MRI was performed for anatomical comparison. Three-dimensional segmentation and quantitative analyses included intervertebral disc (IVD) grading, annulus fibrosus fiber tracing, and vertebral trabecular micro-morphometry. Results: HiP-CT enabled high spatial-resolution, multiscale imaging of the intact human spine, simultaneously visualizing vertebral bone and endplate, IVDs, spinal cord and meninges, nerve roots and ganglia, vasculature, ligaments, and musculature. Three-dimensional segmentation and virtual sectioning mapped neurovascular anatomy and vertebral vascular supply, without exogenous contrast enhancement, while preserving their relationships with surrounding tissues. Whole-spine images enabled quantitative analysis of annulus fibrosus fiber organization and vertebral trabecular microarchitecture, permitting the detection of focal posterolateral fiber disruption at the L4-L5 IVD and regional differences in trabecular architecture between cervical and lumbar vertebral bodies. Local tomography resolved annulus fibrosus lamellae, vertebral endplate Haversian systems, and facet joint hyaline cartilage at micron resolution. Conclusions: HiP-CT enables non-destructive, multiscale three-dimensional imaging of the intact human spine while preserving tissue relationships across spatial scales and tissue boundaries. HiP-CT images could provide an ex vivo microanatomical reference for future correlation with clinical imaging investigations of spinal disease and in the discovery and validation of imaging biomarkers. Key results: Synchrotron-based hierarchical phase-contrast tomography enables non-destructive, multiscale three-dimensional imaging of an intact adult human spine using 16.26 µm isotropic voxels, resolving both mineralized and non-mineralized tissue. Local tomography using 2.2 µm isotropic voxels reveals additional microstructural detail without exogenous contrast agents or sectioning. Whole-spine imaging enables quantitative characterization of intervertebral disc fiber architecture and vertebral trabecular morphometry, alongside visualization of neurovascular anatomy while preserving spatial relationships across the intact specimen. Summary statement: Hierarchical phase-contrast tomography enables non-destructive multiscale imaging of the intact human spine, resolving microarchitecture across tissues and interfaces and providing a basis for bridging clinical imaging with underlying three-dimensional microanatomy.
- Open Access
Multiscale mapping of venous remodelling in idiopathic pulmonary fibrosis
The integrity of the pulmonary vasculature is a key determinant of lung health, yet challenges in visualisation and quantification have hindered interrogation of its pathophysiological role in chronic lung disease. Here, we align recent advances in microscale image acquisition with novel computer vision-based vessel segmentation models to demonstrate expansion of the bronchial and pulmonary veins across varying severities of tissue remodelling in idiopathic pulmonary fibrosis (IPF). Relating these imaging findings to molecular data in control, mild, and severe fibrosis, we show that bronchial venous endothelial cells expand beyond their physiological peribronchial niche even in mild disease, acquiring persistent angiogenic, inflammatory, and matrix-remodelling programmes that define a specialised fibrovascular-immune interface. Finally, we relate these microscale and molecular observations to clinical CT imaging, demonstrating that intrapulmonary vein enlargement independently associates with worsened survival across three IPF cohorts. Collectively, our multimodal, multiscale approach connects previously unresolved three-dimensional venous architecture to its molecular endothelial correlate, establishing venous enlargement as a prognostically significant and clinically relevant feature of IPF. Our analytical approach also demonstrates how biological discoveries made in intact ex vivo human organs can translate into measurable phenotypes in living patients, providing a template for other organs and diseases.
Open AccessMultiscale mapping of venous remodelling in idiopathic pulmonary fibrosis
The integrity of the pulmonary vasculature is a key determinant of lung health, yet challenges in visualisation and quantification have hindered interrogation of its pathophysiological role in chronic lung disease. Here, we align recent advances in microscale image acquisition with novel computer vision-based vessel segmentation models to demonstrate expansion of the bronchial and pulmonary veins across varying severities of tissue remodelling in idiopathic pulmonary fibrosis (IPF). Relating these imaging findings to molecular data in control, mild, and severe fibrosis, we show that bronchial venous endothelial cells expand beyond their physiological peribronchial niche even in mild disease, acquiring persistent angiogenic, inflammatory, and matrix-remodelling programmes that define a specialised fibrovascular-immune interface. Finally, we relate these microscale and molecular observations to clinical CT imaging, demonstrating that intrapulmonary vein enlargement independently associates with worsened survival across three IPF cohorts. Collectively, our multimodal, multiscale approach connects previously unresolved three-dimensional venous architecture to its molecular endothelial correlate, establishing venous enlargement as a prognostically significant and clinically relevant feature of IPF. Our analytical approach also demonstrates how biological discoveries made in intact ex vivo human organs can translate into measurable phenotypes in living patients, providing a template for other organs and diseases.
- Open Access
BigHeart: Mapping connectivity in the adult human heart at the micron scale
The human heart depends on coordinated muscular, electrical, vascular, lymphatic, and neural systems, but their three-dimensional relationships remain unresolved at microscopic resolution across an intact adult organ. Using hierarchical phase-contrast tomography, we generated a continuous three-dimensional structural reference of a whole adult human heart at 8.01 micrometer isotropic voxel size, without sectioning or staining. Organ-wide imaging revealed hierarchical myocardial architecture, and quantitative orientation analysis identified regional differences in myocardial cell aggregate organization. The atrioventricular conduction axis was traced into a distinct subendocardial Purkinje network interfacing with working myocardium. Integrated segmentation showed that coronary vessels, lymphatic collectors, and autonomic nerves occupy shared epicardial corridors. This publicly accessible dataset integrates cardiac systems within a common spatial framework for anatomy, computational modeling, and future molecular atlases.
Open AccessBigHeart: Mapping connectivity in the adult human heart at the micron scale
The human heart depends on coordinated muscular, electrical, vascular, lymphatic, and neural systems, but their three-dimensional relationships remain unresolved at microscopic resolution across an intact adult organ. Using hierarchical phase-contrast tomography, we generated a continuous three-dimensional structural reference of a whole adult human heart at 8.01 micrometer isotropic voxel size, without sectioning or staining. Organ-wide imaging revealed hierarchical myocardial architecture, and quantitative orientation analysis identified regional differences in myocardial cell aggregate organization. The atrioventricular conduction axis was traced into a distinct subendocardial Purkinje network interfacing with working myocardium. Integrated segmentation showed that coronary vessels, lymphatic collectors, and autonomic nerves occupy shared epicardial corridors. This publicly accessible dataset integrates cardiac systems within a common spatial framework for anatomy, computational modeling, and future molecular atlases.
- Open Access
- 12 September 2026
- Published by Elsevier in American Journal of Transplantation
Multimodal analysis of vascular remodeling in human obliterative bronchiolitis after lung transplantation
- 12 September 2026
- Published by Elsevier in American Journal of Transplantation
Open AccessMultimodal analysis of vascular remodeling in human obliterative bronchiolitis after lung transplantation
- Open Access
- 10 September 2026
- Published by Elsevier in The Lancet Medical Imaging & Theranostics
- Vol. 1 (2)
Hierarchical phase-contrast tomography: synchrotron x-ray imaging bridges the gap between histology and radiology
- 10 September 2026
- Published by Elsevier in The Lancet Medical Imaging & Theranostics
- Vol. 1 (2)
Open AccessHierarchical phase-contrast tomography: synchrotron x-ray imaging bridges the gap between histology and radiology
- Open Access
- 19 June 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1169-1179
Fast eikonal phase retrieval for high-throughput beamlines
A fast eikonal phase retrieval formulation is introduced that accelerates eikonal phase retrieval by more than two orders of magnitude while retaining controlled accuracy. The method is derived from a second-order asymptotic expansion in the propagation distance L and complemented by the leading Wentzel–Kramers–Brillouin (WKB) wave-optics correction, yielding an efficient iterative correction scheme preconditioned by fast Fourier transform (FFT)-diagonal, energy-dependent inverse operators (Paganin-type filters). To ensure robustness across practical experimental regimes, we combine two complementary solvers: (i) a local O ( L 2 ) closure that is accurate when eikonal shifts remain sub-pixel, and (ii) a non-local formulation for multi-pixel shifts, in which intensity is propagated through an explicit eikonal ray mapping using a mass-conserving bilinear redistribution on the detector grid, and detector residuals are transferred back to the object grid by the corresponding discrete adjoint (transpose) operator, implemented as bilinear interpolation, before applying an approximate FFT-diagonal preconditioner to accelerate convergence. The same framework supports polychromatic data through a compact spectral discretization, allowing energy-dependent transport and inversion while keeping the iteration efficient for graphics processing unit (GPU)/FFT. Overall, this unified approach enables accurate and computationally efficient phase retrieval across propagation conditions relevant to high-throughput propagation-based phase-contrast micro-tomography experiments.
- 19 June 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1169-1179
Open AccessFast eikonal phase retrieval for high-throughput beamlines
A fast eikonal phase retrieval formulation is introduced that accelerates eikonal phase retrieval by more than two orders of magnitude while retaining controlled accuracy. The method is derived from a second-order asymptotic expansion in the propagation distance L and complemented by the leading Wentzel–Kramers–Brillouin (WKB) wave-optics correction, yielding an efficient iterative correction scheme preconditioned by fast Fourier transform (FFT)-diagonal, energy-dependent inverse operators (Paganin-type filters). To ensure robustness across practical experimental regimes, we combine two complementary solvers: (i) a local O ( L 2 ) closure that is accurate when eikonal shifts remain sub-pixel, and (ii) a non-local formulation for multi-pixel shifts, in which intensity is propagated through an explicit eikonal ray mapping using a mass-conserving bilinear redistribution on the detector grid, and detector residuals are transferred back to the object grid by the corresponding discrete adjoint (transpose) operator, implemented as bilinear interpolation, before applying an approximate FFT-diagonal preconditioner to accelerate convergence. The same framework supports polychromatic data through a compact spectral discretization, allowing energy-dependent transport and inversion while keeping the iteration efficient for graphics processing unit (GPU)/FFT. Overall, this unified approach enables accurate and computationally efficient phase retrieval across propagation conditions relevant to high-throughput propagation-based phase-contrast micro-tomography experiments.
- Open Access
- 19 June 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1180-1189
Evolution of hierarchical phase-contrast tomography on the European Synchrotron beamlines BM05 and BM18: a whole adult human brain imaging case study
Hierarchical phase-contrast tomography (HiP-CT) was recently developed to enable the ex vivo imaging of human organs at multiple scales from whole organ down to near-cellular resolution in localized regions. Using whole adult human brain imaging as a case study, this article shows the evolution and optimization of this technique from its initial development at the BM05 beamline to its transition and current status at BM18. Thanks to the higher spatial coherence, larger beam size, higher energies and larger propagation distances available at BM18 and due to the European Synchrotron's Extremely Brilliant Source upgrade (ESRF-EBS), this transition resulted in significantly improved data quality, resolution, sensitivity and speed. More recently, the implementation of a new generation of larger sCMOS cameras, helical scanning (including dedicated reconstruction algorithm developments), binning at the chip and projections levels, and the design of high-efficiency optics allowed us to progressively improve the trade-off between dose and image quality, and acquisition time. These advances enable whole-organ imaging at voxel sizes ranging from ∼42 µm to ∼15 µm, with acquisition times reduced from ∼18 h to ∼3–6 h, depending on configuration. These acquisition schemes present the current status of full-organ imaging using HiP-CT and represent the constant efforts for improvement of the technique towards the investigation of human organs in health, disease and ageing.
- 19 June 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1180-1189
Open AccessEvolution of hierarchical phase-contrast tomography on the European Synchrotron beamlines BM05 and BM18: a whole adult human brain imaging case study
Hierarchical phase-contrast tomography (HiP-CT) was recently developed to enable the ex vivo imaging of human organs at multiple scales from whole organ down to near-cellular resolution in localized regions. Using whole adult human brain imaging as a case study, this article shows the evolution and optimization of this technique from its initial development at the BM05 beamline to its transition and current status at BM18. Thanks to the higher spatial coherence, larger beam size, higher energies and larger propagation distances available at BM18 and due to the European Synchrotron's Extremely Brilliant Source upgrade (ESRF-EBS), this transition resulted in significantly improved data quality, resolution, sensitivity and speed. More recently, the implementation of a new generation of larger sCMOS cameras, helical scanning (including dedicated reconstruction algorithm developments), binning at the chip and projections levels, and the design of high-efficiency optics allowed us to progressively improve the trade-off between dose and image quality, and acquisition time. These advances enable whole-organ imaging at voxel sizes ranging from ∼42 µm to ∼15 µm, with acquisition times reduced from ∼18 h to ∼3–6 h, depending on configuration. These acquisition schemes present the current status of full-organ imaging using HiP-CT and represent the constant efforts for improvement of the technique towards the investigation of human organs in health, disease and ageing.
- Open Access
Altered Myocardial Structure in Post-natal Tetralogy of Fallot – A Substrate for Interpretation of Ventricular Function and Dysfunction?
BACKGROUND: In tetralogy of Fallot (ToF), changes in right ventricular function (as assessed by strain or TAPSE) reflect altered myocardial structure. Direct three-dimensional anatomical evidence supporting these changes remains limited. The objective of this study was to non-destructively characterize myocardial architecture in pediatric ToF hearts using Hierarchical Phase-Contrast Tomography (HiP-CT) and structure tensor analysis. METHODS: Twenty ToF and control pediatric hearts were imaged at the European Synchrotron, ESRF. Myocyte orientation was assessed through structure tensor analysis and distributed high-performance computing. A region-specific framework was developed for analysis of the right ventricle. The predominant direction of myocardial aggregates (their helical angle) was compared across ventricular regions. RESULTS: Significant differences in orientation were found in all ToF segments vs controls (left ventricle, right ventricular inlet, right ventricular outflow tract, septum; p < 0.001). Myocytes in the ToF right ventricular inlet were more circumferential overall, with regional heterogeneity. Contrary to traditional models, no discrete ‘middle layer’ was found in the ToF right ventricle; instead, a shift towards more circumferentially orientated myocytes and disrupted septal and outflow components was observed. Right ventricular contribution to the septum was greater in ToF (47.3% vs 34.0%; p = 0.0026), with extension of ventricular insertion points disrupting septal architecture. There were more longitudinally oriented myocytes in the ToF right ventricular outflow tract, consistent with hypertrophied septoparietal trabeculations. Left ventricular structure in ToF demonstrated a greater proportion of circumferentially oriented myocytes compared to controls. CONCLUSIONS: We reveal profound alterations in ToF myocardial organization which broadly align with clinical observations and provide the first open-access HiP-CT congenital heart disease data as a basis for future computational modelling. Clinical Perspective: Whole-heart HiP-CT demonstrates a loss of normal LV-RV distinction in the ToF myocardium, alongside extensive septal disarray. These findings provide a structural substrate for RV dysfunction, ventricular-ventricular interaction, and arrhythmogenesis in ToF, challenging traditional layer-based models of ventricular myocardium. Understanding myocardial organization as a continuous, developmentally patterned three-dimensional structure is essential for accurate interpretation of ventricular mechanics and disease progression. Although HiP-CT imaging is not applicable in vivo, the structural phenotypes identified in this study generate testable hypotheses for clinical imaging. Future work should focus on correlating ex-vivo measures with in-vivo imaging markers derived from cardiac magnetic resonance, including strain, TAPSE, and assessment of ventricular interactions. Investigating myocardial phenotype across the life-course, from fetal life to adulthood, paired with multi-omics mapped to these three-dimensional datasets, may help elucidate mechanisms underlying myocardial remodeling in ToF and support the development of novel therapeutic approaches.
Open AccessAltered Myocardial Structure in Post-natal Tetralogy of Fallot – A Substrate for Interpretation of Ventricular Function and Dysfunction?
BACKGROUND: In tetralogy of Fallot (ToF), changes in right ventricular function (as assessed by strain or TAPSE) reflect altered myocardial structure. Direct three-dimensional anatomical evidence supporting these changes remains limited. The objective of this study was to non-destructively characterize myocardial architecture in pediatric ToF hearts using Hierarchical Phase-Contrast Tomography (HiP-CT) and structure tensor analysis. METHODS: Twenty ToF and control pediatric hearts were imaged at the European Synchrotron, ESRF. Myocyte orientation was assessed through structure tensor analysis and distributed high-performance computing. A region-specific framework was developed for analysis of the right ventricle. The predominant direction of myocardial aggregates (their helical angle) was compared across ventricular regions. RESULTS: Significant differences in orientation were found in all ToF segments vs controls (left ventricle, right ventricular inlet, right ventricular outflow tract, septum; p < 0.001). Myocytes in the ToF right ventricular inlet were more circumferential overall, with regional heterogeneity. Contrary to traditional models, no discrete ‘middle layer’ was found in the ToF right ventricle; instead, a shift towards more circumferentially orientated myocytes and disrupted septal and outflow components was observed. Right ventricular contribution to the septum was greater in ToF (47.3% vs 34.0%; p = 0.0026), with extension of ventricular insertion points disrupting septal architecture. There were more longitudinally oriented myocytes in the ToF right ventricular outflow tract, consistent with hypertrophied septoparietal trabeculations. Left ventricular structure in ToF demonstrated a greater proportion of circumferentially oriented myocytes compared to controls. CONCLUSIONS: We reveal profound alterations in ToF myocardial organization which broadly align with clinical observations and provide the first open-access HiP-CT congenital heart disease data as a basis for future computational modelling. Clinical Perspective: Whole-heart HiP-CT demonstrates a loss of normal LV-RV distinction in the ToF myocardium, alongside extensive septal disarray. These findings provide a structural substrate for RV dysfunction, ventricular-ventricular interaction, and arrhythmogenesis in ToF, challenging traditional layer-based models of ventricular myocardium. Understanding myocardial organization as a continuous, developmentally patterned three-dimensional structure is essential for accurate interpretation of ventricular mechanics and disease progression. Although HiP-CT imaging is not applicable in vivo, the structural phenotypes identified in this study generate testable hypotheses for clinical imaging. Future work should focus on correlating ex-vivo measures with in-vivo imaging markers derived from cardiac magnetic resonance, including strain, TAPSE, and assessment of ventricular interactions. Investigating myocardial phenotype across the life-course, from fetal life to adulthood, paired with multi-omics mapped to these three-dimensional datasets, may help elucidate mechanisms underlying myocardial remodeling in ToF and support the development of novel therapeutic approaches.
- Open Access
Hierarchical X-ray microscopy and mesoscopic diffusion MRI in the same brain reveal the human connectome across scales
We present a multimodal pipeline for 3D imaging of cerebral white-matter archi-tecture across scales, from whole-brain axonal projections down to individual myelinated axons. After diffusion MRI, an adult ex vivo human hemisphere undergoes label-free imaging with Hierarchical Phase-Contrast Tomography (HiP-CT) from 20 µm/voxel in the whole hemisphere to 2 µm/voxel in areas of interest, with intrinsic cross-scale alignment. A 4 cm tissue block extracted from the hemisphere is reimaged with HiP-CT at 0.857 µm/voxel, enabling direct visualisation of single myelinated axons. After osmium staining, micro-CT at 0.364 µm/voxel and electron microscopy at 4 nm/voxel are acquired in biop-sies from the tissue block to validate the presence of myelinated axons in the label-free HiP-CT contrast. Spanning three orders of magnitude in resolution, these co-registered multimodal datasets bridge microscopic wiring and macro-scopic brain organisation, providing a foundation for anatomically grounded whole-brain connectomics.
Open AccessHierarchical X-ray microscopy and mesoscopic diffusion MRI in the same brain reveal the human connectome across scales
We present a multimodal pipeline for 3D imaging of cerebral white-matter archi-tecture across scales, from whole-brain axonal projections down to individual myelinated axons. After diffusion MRI, an adult ex vivo human hemisphere undergoes label-free imaging with Hierarchical Phase-Contrast Tomography (HiP-CT) from 20 µm/voxel in the whole hemisphere to 2 µm/voxel in areas of interest, with intrinsic cross-scale alignment. A 4 cm tissue block extracted from the hemisphere is reimaged with HiP-CT at 0.857 µm/voxel, enabling direct visualisation of single myelinated axons. After osmium staining, micro-CT at 0.364 µm/voxel and electron microscopy at 4 nm/voxel are acquired in biop-sies from the tissue block to validate the presence of myelinated axons in the label-free HiP-CT contrast. Spanning three orders of magnitude in resolution, these co-registered multimodal datasets bridge microscopic wiring and macro-scopic brain organisation, providing a foundation for anatomically grounded whole-brain connectomics.