YGYichen Guo

Yichen Guo

*This is an algorithmically generated author record based on publicly available information.

Yichen Guo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Guozhen Guo

    Department of Radiation Biology, Air Force Medical University 3 , Xi’an 710032, China

    1 shared publication
  • Haiyang Lang

    Department of Radiation Medicine and Protection, Faculty of Preventive Medicine, Airforce Medical University, Xi’an, Shaanxi 710032, China

    1 shared publication
  • Jing Li

    Department of Animals Sciences, College of Animal Sciences, Jilin University, Changchun, China

    1 shared publication
  • Li-Hua Zeng

    Department of Radiation Medicine and Protection, Faculty of Preventive Medicine, Airforce Medical University, Xi’an, Shaanxi 710032, China

    1 shared publication
  • Peng Gao

    Department of Radiation Medicine and Protection, Faculty of Preventive Medicine, Airforce Medical University, Xi’an, Shaanxi 710032, China

    1 shared publication
  • Qin Chen

    Department of Radiation Medicine and Protection, Faculty of Preventive Medicine, Airforce Medical University, Xi’an, Shaanxi 710032, China

    1 shared publication

Latest Publications

  • Open Access

    Effects of Long‐Term Exposure to L‐Band High‐Power Microwave on the Brain Function of Male Mice

    by Yanyun Lin, Peng Gao, Yichen Guo, Qin Chen, Haiyang Lang, Qiyan Guo, Xia Miao, Jing Li, Lihua Zeng, Guozhen Guo

    Currently, the impact of electromagnetic field (EMF) exposure on the nervous system is an increasingly arousing public concern. The present study was designed to explore the effects of continuous long‐term exposure to L‐band high‐power microwave (L‐HPM) on brain function and related mechanisms. Forty‐eight male Institute of Cancer Research (ICR) mice were exposed to L‐HPM at various power densities (0.5, 1.0, and 1.5 W/m2) and the brain function was examined at different time periods after exposure. The morphology of the brain was examined by hematoxylin‐eosin (HE) and deoxynucleotidyl transferase‐mediated dUTP nick‐end labeling (TUNEL) staining. Furthermore, cholinergic markers, oxidative stress markers, and the expression of c‐fos were evaluated to identify a “potential” mechanism. The results showed that exposure to L‐HPM at 1.5 W/m2 can cause generalized injuries in the hippocampus (CA1 and CA3) and cerebral cortex (the first somatosensory cortex) of mice, including cell apoptosis, cholinergic dysfunction, and oxidative damage. Moreover, the deleterious effects were closely related to the power density and exposure time, indicating that long‐term and high‐power density exposure may be detrimental to the nervous system.