KVKsenia I. Voevodina

Ksenia I. Voevodina

*This is an algorithmically generated author record based on publicly available information.

Ksenia I. Voevodina has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of individual listening devices (headphones) on the development of hearing loss

    by A.V. Pashkov, V.G. Kunitsyna, P.L. Vorobyeva, K.I. Voevodina, L.S. Namazova-Baranova, I.V. Naumova

    According to the World Health Organization (WHO), there is an increase in the prevalence of noise-induced hearing loss (NIHL). The highest growth rate of NIHL is noted among children and adolescents. According to the results of previous studies, 40% of students aged 16 to 25 were diagnosed with NIHL in 1996. 12.5% of students aged 6 to 19 were found to have shifts in sound perception thresholds that may be associated with noise exposure. The growing prevalence of the use of individual listening devices (headphones) is considered one of the most significant causes of the growth of noise-induced hearing loss in all age groups. Material and methods. A search of literary sources was conducted on the study of the effect of individual listening devices on the development of sensorineural (neurosensory) hearing loss. The search was conducted in the international PubMed database; the search query was formulated as (noise-induced hearing loss) AND (headphones). Results. The review includes the results of the search and analysis of literature sources that reflect the effect of individual listening devices on the state of the auditory organ. The analysis revealed that long-term exposure to high-intensity sounds can cause NIHL in people of different ages. Despite the existing WHO recommendations on the intensity/duration of safe use of headphones, further study of this issue is necessary taking into account modern capabilities of processing and delivering sound information.

  • Pure-tone audiometry and ASSR to acoustic stimulation as predictors of speech intelligibility in ci-users

    by I.V. Naumova, K.I. Voevodina, V.G. Kunitsyna, A.V. Pashkov, P.A. Rubinshtein, L.S. Namazova-Baranova, P.L. Vorobyeva

    Objective. To compare the possibility of using behavioral thresholds and auditory steady-state responses in a free field in pediatric CI-users as predictors of speech intelligibility. Material and methods. 170 CI-users with reliable behavioral feedback aged 6 to 17 years were included in the study. The assessment of behavioral thresholds and speech intelligibility was carried out in a free field. An objective assessment of sound perception was carried out in a free field by Auditory Steady State Responses (ASSR). A correlation analysis was performed between the indicators of speech intelligibility and the values of behavioral thresholds and ASSR. Results. A significant negative correlation (p<0.01) of speech intelligibility and ASSR in all carrier frequencies was revealed. It makes possible to consider the threshold values ASSR in free field as a reliable predictor of speech intelligibility in silence. The relationship between speech intelligibility and behavioral thresholds was considered insignificant (in the range of all frequencies, p ≥0.05) Conclusion. The ability to accurately predict speech intelligibility based on auditory steady-state responses (ASSR) is a useful option for determination of the parameters of electrical stimulation in CI-users.

  • Indicators of registration of auditory brainstem responses in children with autism spectrum disorder

    by A.V. Pashkov, M.T. Fatakhova, N.V. Ustinova, L.S. Namazova-Baranova, I.V. Naumova, V.G. Kunitsyna, P.A. Rubinshtein, K.I. Voevodina, D.S. Chirkina, A.M. Mamedyarov

    Objective. To evaluate the latency of the components of the auditory brainstem responses (ABR) in children with autism spectrum disorder (ASD) in age 2-3 years in comparison with the norm. Material and methods. The research includes the results of studies of 12 children with a confirmed diagnosis of ASD, including 9 boys and 3 girls aged 24 to 33 months. To assess the auditory function all children were recorded using auditory brainstem responses with a broadband click as a stimulus. At the first stage of the study, we determined the threshold of ABR recording to exclude the presence of hearing loss. Children with hearing disorders (4 people) were not included in the study — they were allocated to a separate group for further observation. The second stage of the study was a comparative analysis of the latency of wave V in patients with ASD without hearing impairment and children with normotypic development. Results. The average latency value of the wave V in the group of children with autism spectrum disorders was 6.34 ms (Mann-Whitney U-test, p≥0.05 with a growth trend, indicating a lack of statistical significance), normally 6.75-6.90 ms. The standard deviation was 0.4 (6.37%). Discussion. The deviation of latency indicators from the norm on the screening values of the ABR stimulus can be considered a biomarker of autism spectrum disorders. To exclude or confirm ASD children with such changes should be referred for consultation to specialized specialists.

  • On possible causes of discrepancy between the results of auditory brainstem responses (ABR) and auditory steady-state responses (ASSR) recordings

    by L.S. Namazova-Baranova, N.V. Ustinova, I.V. Naumova, M.T. Fatakhova, K.I. Voevodina, A.E. Pashkova, V.I. Popadyuk, V.G. Kunitsyna, P.A. Rubinshtein

    Auditory brainstem responses (ABR) and auditory steady-state responses (ASSR) are the most widely used tests for objective hearing assessment. These tests are included in clinical guidelines for sensorineural hearing loss and other protocols. The literature sources describe examples of inconsistency between the results of these two tests, which are suggested to be interpreted in favor of ABR as the test with the highest values of sensitivity and specificity. Also, in a number of cases, discrepancy between the results of ABR and ASSR recordings in patients with neurological pathology was revealed. Given the expanding indications for auditory evoked potentials recording in groups of patients with neurological or psychiatric pathologies (for example, ABR and ASSR are recommended for use in clinical guidelines for the management of patients with autism spectrum disorders in 2020), an attempt has been made to assess the diagnostic value of these research methods in relation to conditions unrelated to hearing impairment. Material and methods. A diagnostic search of domestic and foreign literature was conducted on the combined interpretation of the results of ABR and ASSR recording was carried out. Literature on the use of these tests in groups of patients without sensorineural hearing loss was also reviewed. Results. The review includes the results of a literature search that provides a comparative analysis of ABR and ASSR results, including in patients with neurologic/psychiatric pathology. The analysis showed that ASSR recording results may significantly differ from the ABR response, which should be taken into account in patients with comorbidities.


  • Open Access

    Psychophysical and Electrophysiological Parameters of the Auditory Analyzer as Indicators of the Effectiveness of Cochlear Implantation in Children with Bilateral Deafness

    by Aleksandr V. Pashkov, Irina V. Naumova, Ksenia I. Voevodina, Alexandra Е. Pashkova, Valentin I. Popadyuk, Natalia V. Ustinova, Ayaz M. Mamedyarov, Мамедьяров Аяз Магерамович

    Background. The results of rehabilitation of patients with deafness after cochlear implantation (CI) depends on many factors related on both the individual characteristics of the patient and the technical parameters of auditory nerve stimulation — fitting of the CI system processor. Article presents the results of a study of the relationship between psychophysical (subjective) auditory sensations and electrophysiological (objective) responses of the structures of the auditory analyzer to electrical stimulation. Aims — to evaluate the relationship between the electrophysiological responses of the auditory analyzer and the psychophysical parameters of the thresholds of sound perception and speech intelligibility in patients with deafness after CI. Methods. The study involved 88 patients with IV bilateral sensorineural hearing loss, borderline with deafness, aged 6 to 17 years 11 months, among whom 54.5% (n = 48) of girls and 45.5% (n = 40) of boys. Of the patients included in the follow-up, 40% (n = 35) underwent unilateral CI; 60% (n = 53) of children underwent bilateral sequential CI. In our study, slightly more than half of the patients (51.1%) had experience using the CI system for more than 5 years. At the first stage of the study, we studied the relationship between sound perception thresholds (tonal audiometry in a free field) and registered ASSR (auditory steady state response) thresholds in patients with deafness receiving rehabilitation after CI surgery. The relationship between behavioral and electrophysiological (objective) thresholds was assessed by comparing the results of tonal threshold audiometry and the responses received during ASSR registration to acoustic stimulation in a free field. At the second stage, patients with indications for processor fitting (decreased speech intelligibility, uncomfortable sensations) underwent speech audiometry, evoked compound action potentials (ECAP) registration, according to the results of which the parameters of the CI processor were changed. Results. Research data showed the effectiveness of the approach of including the ECAP registration test, followed by the creation of a fitting card and correction of the level of auditory nerve stimulation under the control of speech audiometry in the protocol of fitting the CI processor. Conclusions. The results of the conducted studies allow us to recommend the use of the developed method of objective recording of sound perception thresholds in patients with CI as one of the indicators of the effectiveness of CI in the early period of auditory-speech rehabilitation in patients with undeveloped speech skills and when it is impossible to conduct objective tests accompanied by supra-threshold stimulation of the auditory nerve.


  • Open Access

    Features of processor fitting in patients with different types of cochlear implant electrode array

    by A. Е. Pashkova, V. I. Popadyuk, K. I. Voevodina, I. V. Naumova, I. M. Kirichenko, A. V. Pashkov

    Introduction. The results of cochlear implantation in patients with bilateral sensorineural hearing loss are influenced by many factors, including the type of electrode array. The location of the electrodes in relation to neurons of spiral ganglion affects on levels of perception of the patient's hearing sensations.Aim. To evaluate the dependence of electrically evoked compound action potential (ECAP) thresholds values and comfortable levels depends on electrode array type.Materials and methods. 26 patients with bilateral sensorineural hearing loss with cochlear implantation systems were examined. The patients were divided into 2 groups: 1) patients with a straight electrode array (n = 14); 2) patients with a perimodiolar electrode array (n = 12). We tested speech intelligibility and ECAP thresholds. The difference in the values of both parameters was estimated.Results. For both groups of patients, the relationship between the threshold's profiles of ECAP thresholds and maximum comfortable stimulation levels was detected. For patients from the first group (straight electrode array), the differences in values between the studied parameters were 30.6 ± 6.1%. In patients from the second group, the differences in the values of the thresholds for ECAP thresholds and the levels of comfortable stimulation ranged 2.4 ± 2.1%.Conclusion. The perimodiolar electrode array is located closer to the neurons of the spiral ganglion, which may explain the greater relationship between the values of the ECAP thresholds and the levels of comfortable stimulation. This pattern must be considered when programming the processor of the cochlear implantation system.


  • Application of registration of stationary auditory potentials in free sound field in deaf-blind child

    by K. I. Voevodina, M. T. Fatakhova, A. E. Pashkova, D. S. Klyachko

    Deafblindness is a rare disease in which a person has a combination of hearing loss and vision loss, resulting in reduced access to both auditory and visual information. There are many reasons to occur of deafblindness: hereditary syndromes/disorders (CHARGE syndrome, Usher’s syndrome, Down’s syndrome), diseases that occurred before childbirth (cytomegalovirus, hydrocephalus, microcephaly), etc. The article presents a clinical case of an 11-year-old patient with a diagnosis of severe bilateral sensorineural hearing loss, condition after cochlear implantation on the right in 2012. Retinopathy of prematurity of the 5th degree, total retinal detachment with severe intraretinal proliferation. Infantile cerebral palsy. Hyperhomocysteinemia. Mitochondrial dysfunction. Casein intolerance. Persistent viral infection of Herpes Simplex Virus (HSV) type 6, Epstein–Barr virus (EBV). The authors showed a method for fitting the cochlear implant (CI) processor in a deaf-blind child by assessing the thresholds for perceiving sounds at different speech frequencies (500 Hz–4,000 Hz), which is the registration via Auditory Steady State Response (ASSR) to acoustic stimuli delivered through loudspeakers to an activated cochlear implant processor.


  • Speech perception and the state of sound perception thresholds in patients with cochlear implants

    by I.V. Naumova, A.V. Pashkov, K.I. Voevodina, M.T. Fatakhova

    ЦЕЛЬ ИССЛЕДОВАНИЯ Оценить состояние порогов звуковосприятия на речевых частотах у пользователей систем кохлеарной имплантации с развитыми речевыми навыками. МАТЕРИАЛ И МЕТОДЫ В исследовании участвовали 30 пациентов — пользователей систем кохлеарной имплантации, из них 17 девочек и 13 мальчиков в возрасте от 6 до 14 лет. Всем пациентам дважды проводили речевую аудиометрию в свободном звуковом поле (в начале исследования и после коррекции настроек речевого процессора). Регистрацию стационарных слуховых потенциалов (ASSR) осуществляли после коррекции настроек речевого процессора для оценки восприятия неречевых стимулов. РЕЗУЛЬТАТЫ Проведен корреляционный анализ между показателями разборчивости речи и средним значением порогов ASSR. Статистически значимая взаимосвязь между значениями порогов ASSR и показателями разборчивости речи не отмечена. Выявлено отсутствие взаимосвязи между разборчивостью речи и удовлетворенностью пользователя настройками процессора. Повышение уровня разборчивости речи не влияло на улучшение реакции на обращенную речь. ЗАКЛЮЧЕНИЕ Основным предназначением проведения кохлеарной имплантации является социальная интеграция пациента с глухотой в речевую среду, поэтому для оценки эффективности реабилитационного процесса у пациентов с развитыми речевыми навыками необходимо применять тесты речевой аудиометрии.


  • Open Access

    Automated Audiometry as the Screening of Hearing in Schoolchildren: Literature Review and Own Experience

    by Aleksandr V. Pashkov, Irina V. Naumova, Irina V. Zelenkova, Leila S. Namazova-Baranova, Elena A. Vishneva, Ksenia I. Voevodina

    In the era of healthcare digitalization, automation of some medical processes becomes extremely crucial, especially in situations where it is not possible to receive support quickly enough, for example, due to long wait for a specialist (queues) or absence of the needed specialist. This approach will help to use healthcare resources effectively. Automated audiometry is an example of automated diagnostic procedure based on algorithms and technical means for recording acoustic threshold in order to determine the hearing conditions. This review describes the process of automated hearing testing technology development in detail and several other system components (software, equipment, acoustic stimulation sources). The authors describe their own experience of using the automatic audiometry system. The results of comparative study of automated and clinical tests are presented.


  • Open Access

    Possibilities of triphasic stimulation in patients with cochlear implants

    by A. V. Pashkov, I. V. Naumova, K. I. Voevodina, D. S. Klyachko, M. T. Fatakhova, D. D. Kalyapin

    Архив медицинского научно-практического журнала «Российская оториноларингология»