ISItsuko Serizawa

Itsuko Serizawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Itsuko Serizawa has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction to: Preliminary result of carbon-ion radiotherapy using the spot scanning method for prostate cancer

    by Yosuke Takakusagi, Hiroyuki Katoh, Kio Kano, Wataru Anno, Keisuke Tsuchida, Nobutaka Mizoguchi, Itsuko Serizawa, Daisaku Yoshida, Tadashi Kamada

  • Open Access

    Evaluation of Safety for Scanning Carbon-Ion Radiotherapy in Hemodialysis Patients With Prostate Cancer

    by Yosuke Takakusagi, Makito Suga, Yohsuke Kusano, Kio Kano, Satoshi Shima, Keisuke Tsuchida, Nobutaka Mizoguchi, Itsuko Serizawa, Daisaku Yoshida, Tadashi Kamada, et al.

    The efficacy and safety of carbon-ion radiotherapy (CIRT) for prostate cancer have already been demonstrated. The number of hemodialysis (HD) patients is increasing. Although the toxicity of CIRT in HD patients may be more severe, it has been insufficiently investigated. Therefore, we retrospectively analyzed the safety of CIRT for HD patients with prostate cancer in the present study. Five HD patients with prostate cancer who underwent CIRT at the Kanagawa Cancer Center during November 2015-2020 were included in this study. CIRT was delivered by the raster scanning method (sCIRT). Adverse events were assessed using the Common Terminology Criteria for Adverse Events version 5.0. The dose-volume histogram (DVH) parameters of the target volume and normal organs were evaluated between initial planning computed tomography (CT) and in-room CT images. In the acute phase, Grade 1 genitourinary toxicity was recorded in one patient. In the late phase, Grade 1 genitourinary toxicity was recorded in two patients. No gastrointestinal toxicities were noted during the follow-up period. In-room CT analysis revealed no significant differences among all DVH parameters of the target volume and normal organs when compared with the treatment plan dose. The safety of sCIRT for prostate cancer in HD patients was investigated in the present study. In-room CT analysis suggested the robustness of the treatment plan. According to the present results, sCIRT for prostate cancer can be safely performed in HD patients.


  • Open Access

    Three cases of retroperitoneal sarcoma in which bioabsorbable spacers (bioabsorbable polyglycolic acid spacers) were inserted prior to carbon ion radiotherapy

    by Itsuko Serizawa, Yohsuke Kusano, Kio Kano, Satoshi Shima, Keisuke Tsuchida, Yosuke Takakusagi, Nobutaka Mizoguchi, Tadashi Kamada, Daisaku Yoshida, Hiroyuki Katoh

    From August 2019 to August 2020, we inserted polyglycolic acid (PGA) spacers and administered carbon ion radiotherapy (CIRT) to three cases of retroperitoneal sarcoma at our hospital. We aimed to investigate its utility and safety for retroperitoneal sarcoma. We analyzed changes in PGA spacer volume and corresponding computed tomography (CT) values in addition to the dose distribution using in-room CT images that were obtained during treatment. We assessed adverse events and investigated the suitability, safety and effectivity of PGA spacer insertion. During treatment, changes in PGA spacer volumes and CT values were confirmed. Volumes increased in patients with a folded PGA spacer, and it increased 1.6-fold by the end of irradiation compared with planning CT. The CT values decreased by 20–50 Hounsfield units at the end of irradiation compared to the planning CT. Dose distribution evaluation showed that the dose to the gastrointestinal tract adjacent to the tumor was maintained below the tolerable dose, and a sufficient dose was delivered to the target by PGA spacer insertion. One case of subileus caused during abdominal surgery for PGA spacer insertion occurred. No other adverse events, such as digestive disorders, were observed. CIRT with PGA spacer insertion for retroperitoneal sarcomas is safe and effective. For cases in which there is no option but to perform irradiation using a PGA spacer, precautionary measures such as verification of dose distributions using CT images are necessary.


  • Open Access

    Comparison of Clinical Outcomes of Definitive and Postoperative Radiotherapy for Adenoid Cystic Carcinoma of the Head and Neck: Can Definitive Radiotherapy Be a Treatment Option?

    by Nobutaka Mizoguchi, Kio Kano, Satoshi Shima, Keisuke Tsuchida, Yosuke Takakusagi, Itsuko Serizawa, Keiko Akahane, Masahiro Kawahara, Manatsu Yoshida, Yuka Kitani, et al.

    Background: The standard treatment for adenoid cystic carcinoma of the head and neck is surgical resection followed by postoperative radiotherapy (PORT). Currently, definitive radiotherapy (defRT) is considered an inadequate treatment; however, its data are based on studies using classical radiotherapy techniques. Therefore, the therapeutic effects of current radiotherapy techniques have not been adequately evaluated, and it may have underestimated the efficacy of defRT. Methods: We retrospectively analyzed 44 adenoid cystic carcinoma patients treated with radiotherapy based on modern treatment techniques from 1993 to 2017. Results: Twenty-four patients underwent PORT and 20 patients underwent defRT. The 5-year overall survival rates for patients treated with PORT and defRT were 85.3% and 79.7%, respectively. The 5-year local control rates were 82.5% and 83.1%, respectively. There were no statistically significant differences in the overall survival and local control of patients treated with PORT and defRT (p = 0.4392 and p = 0.0904, respectively). Conclusion: Our results show that defRT is comparable to surgical resection followed by PORT with respect to overall survival and local control. The results suggest that defRT can be an effective treatment option for adenoid cystic carcinoma of the head and neck.


  • Open Access

    Validation of the Reliability of Machine Translation for a Medical Article From Japanese to English Using DeepL Translator

    by Yosuke Takakusagi, Takahiro Oike, Katsuyuki Shirai, Hiro Sato, Kio Kano, Satoshi Shima, Keisuke Tsuchida, Nobutaka Mizoguchi, Itsuko Serizawa, Daisaku Yoshida, et al.

    The reliability of DeepL Translator (DeepL GmbH, Cologne, Germany) for the translation for medical articles has not been verified yet. In this study, we investigated the accuracy of machine translation from Japanese to English for a medical article using the DeepL Translator. The subject of this study was an English-language medical article translated from Japanese, which had already been published. The original Japanese manuscript was translated into English using DeepL Translator. The translated English article was then back-translated into Japanese by three researchers. In turn, three other researchers compared the back-translated Japanese sentences with the original Japanese manuscript and calculated the percentage of sentences that retained the intended meaning. The mean ± standard deviation of the match rate for the entire article was 94.0 ± 2.9%. The match rate in the Results section was significantly higher than that in the other sections; while the match rate in the Materials and Methods section was significantly lower than the rate in the other sections. Compound sentences and sentences with an unclear subject and predicate appeared to be significant predictors for mismatched translation. The translation for a medical article from Japanese to English was performed accurately by DeepL Translator.