CEChristian Erdmann

Christian Erdmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christian Erdmann has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Population health and implementation outcomes of self-testing for SARS-CoV-2 using antigen detecting diagnostics: a systematic review and meta-analysis

    by Lukas E. Brümmer, Verena Faehling, Sean McGrath, Ana-Mihaela Zorger, Karina Worbes, Christian Erdmann, Hannah Tolle, Stephan Katzenschlager, Seda Yerlikaya, Maurizio Grilli, et al.


  • Open Access

    The clinical utility and epidemiological impact of self-testing for SARS-CoV-2 using antigen detecting diagnostics: a systematic review and meta-analysis

    by Lukas E. Brümmer, Christian Erdmann, Hannah Tolle, Sean McGrath, Ioana D. Olaru, Stephan Katzenschlager, Seda Yerlikaya, Maurizio Grilli, Nira R. Pollock, Berra Erkosar, et al.

    Introduction Self-testing for COVID-19 (C19ST) based on antigen detecting diagnostics could significantly support controlling the SARS-CoV-2 pandemic. To inform the World Health Organization in developing a C19ST guideline, we performed a systematic review and meta-analysis of the available literature. Methods We electronically searched Medline and the Web of Science core collection, performed secondary reference screening, and contacted experts for further relevant publications. Any study published between December 1, 2020 and November 30, 2021 assessing the epidemiological impact and clinical utility of C19ST was included. Study quality was evaluated using the Newcastle Ottawa Scale (NOS). The review was registered on PROSPERO (CRD42022299977). Results 11 studies only from high-income countries with an overall low quality (median of 3/9 stars on the NOS) were found. Pooled C19ST positivity was 0.2% (95% CI 0.1% to 0.4%; eight data sets) in populations where otherwise no dedicated testing would have occurred. The impact of self-testing on virus transmission was uncertain. Positive test results mainly resulted in people having to isolate without further confirmation of results (eight data sets). When testing was voluntary by study design, pooled testing uptake was 53.2% (95% CI 36.7% to 68.9%; five data sets. Outside direct health impacts, C19ST reduced quarantine duration and absenteeism from work, and made study participants feel safer. Study participants favored self-testing and were confident that they performed testing and sampling correctly. Conclusions The present data suggests that C19ST could be a valuable tool in reducing the spread of COVID-19, as it can achieve good uptake, may identify additional cases, and was generally perceived as positive by study participants. However, data was very limited and heterogenous, and further research especially in low- and middle-income countries is needed to assess the clinical utility and epidemiological impact of C19ST in more detail. CONTRIBUTIONS TO THE LITERATURE - COVID-19 self-testing (C19ST) using antigen detection could conceivably support pandemic control. A current PubMed search found no systematic evidence synthesis of studies assessing the epidemiological impact and clinical utility of C19ST implementation - We systematically reviewed and meta-analyzed 11 studies including more than 1.1 million persons tested - C19ST can achieve good uptake, may identify additional cases, and was general perceived as positive by study participants, suggesting it to be a valuable tool in reducing the spread of SARS-CoV-2 - Further data especially from low- and middle-income countries is needed to understand the impact of C19ST in more detail


  • Open Access

    Accuracy of rapid point-of-care antigen-based diagnostics for SARS-CoV-2: An updated systematic review and meta-analysis with meta-regression analyzing influencing factors

    by Lukas E. Brümmer, Stephan Katzenschlager, Sean McGrath, Stephani Schmitz, Mary Gaeddert, Christian Erdmann, Marc Bota, Maurizio Grilli, Jan Larmann, Markus A. Weigand, et al.

    Background: Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. Methods and findings: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values 90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.


  • Open Access

    Accuracy of rapid point-of-care antigen-based diagnostics for SARS-CoV-2: an updated systematic review and meta-analysis with meta regression analyzing influencing factors

    by Lukas E. Brümmer, Stephan Katzenschlager, Sean McGrath, Stephani Schmitz, Mary Gaeddert, Christian Erdmann, Marc Bota, Maurizio Grilli, Jan Larmann, Markus A. Weigand, et al.

    Background Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. Methods and findings We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariate mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1), respectively. When manufacturer instructions were followed, sensitivity increased to 76.4% (95%CI 73.8 to 78.8). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (sensitivity of 97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values <20 and 90%). With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.


  • Top Cited Papers
    Open Access

    Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis

    by Lukas E. Brümmer, Stephan Katzenschlager, Mary Gaeddert, Christian Erdmann, Stephani Schmitz, Marc Bota, Maurizio Grilli, Jan Larmann, Markus A. Weigand, Nira R. Pollock, et al.

    Background: SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs) are increasingly being integrated in testing strategies around the world. Studies of the Ag-RDTs have shown variable performance. In this systematic review and meta-analysis, we assessed the clinical accuracy (sensitivity and specificity) of commercially available Ag-RDTs.Methods and findings: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 up until 30 April 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity in comparison to reverse transcription polymerase chain reaction (RT-PCR) testing. We assessed heterogeneity by subgroup analyses, and rated study quality and risk of bias using the QUADAS-2 assessment tool. From a total of 14,254 articles, we included 133 analytical and clinical studies resulting in 214 clinical accuracy datasets with 112,323 samples. Across all meta-analyzed samples, the pooled Ag-RDT sensitivity and specificity were 71.2% (95% CI 68.2% to 74.0%) and 98.9% (95% CI 98.6% to 99.1%), respectively. Sensitivity increased to 76.3% (95% CI 73.1% to 79.2%) if analysis was restricted to studies that followed the Ag-RDT manufacturers’ instructions. LumiraDx showed the highest sensitivity, with 88.2% (95% CI 59.0% to 97.5%). Of instrument-free Ag-RDTs, Standard Q nasal performed best, with 80.2% sensitivity (95% CI 70.3% to 87.4%). Across all Ag-RDTs, sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values, i.e., <20 (96.5%, 95% CI 92.6% to 98.4%) and <25 (95.8%, 95% CI 92.3% to 97.8%), in comparison to those with Ct ≥ 25 (50.7%, 95% CI 35.6% to 65.8%) and ≥30 (20.9%, 95% CI 12.5% to 32.8%). Testing in the first week from symptom onset resulted in substantially higher sensitivity (83.8%, 95% CI 76.3% to 89.2%) compared to testing after 1 week (61.5%, 95% CI 52.2% to 70.0%). The best Ag-RDT sensitivity was found with anterior nasal sampling (75.5%, 95% CI 70.4% to 79.9%), in comparison to other sample types (e.g., nasopharyngeal, 71.6%, 95% CI 68.1% to 74.9%), although CIs were overlapping. Concerns of bias were raised across all datasets, and financial support from the manufacturer was reported in 24.1% of datasets. Our analysis was limited by the included studies’ heterogeneity in design and reporting.Conclusions: In this study we found that Ag-RDTs detect the vast majority of SARS-CoV-2-infected persons within the first week of symptom onset and those with high viral load. Thus, they can have high utility for diagnostic purposes in the early phase of disease, making them a valuable tool to fight the spread of SARS-CoV-2. Standardization in conduct and reporting of clinical accuracy studies would improve comparability and use of data.