Elisaveta Prosetskaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elisaveta Prosetskaya has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Evgeniy N. Bolbasov
National Research Tomsk Polytechnic University
3 shared publications - Semen Goreninskii
Additive Technologies Center, Tomsk Polytechnic University, Tomsk 634000, Russia
3 shared publications - Yuriy N. Yurjev
National Research Tomsk Polytechnic University, Tomsk, Russia
3 shared publications - Elizaveta Sviridova
Research School of Chemistry & Applied Biomedical Sciences, Tomsk Polytechnic University, Tomsk 634050, Russia
2 shared publications - Evgenii Plotnikov
National Research Tomsk Polytechnic University
2 shared publications - Alexander I. Mishanin
Almazov National Medical Research Centre, Akkuratova 2, St. Petersburg 197341, Russia
1 shared publication
Latest Publications
- Open Access
Nitrogen-Doped Diamond-like Coatings for Long-Term Enhanced Cell Adhesion on Electrospun Poly(ε-caprolactone) Scaffold Surfaces
Electrospun poly(ε-caprolactone) (PCL)-based scaffolds are widely used in tissue engineering. However, low cell adhesion remains the key drawback of PCL scaffolds. It is well known that nitrogen-doped diamond-like carbon (N-DLC) coatings deposited on the surface of various implants are able to enhance their biocompatibility and functional properties. Herein, we report the utilization of the pulsed vacuum arc deposition (PVAD) technique for the fabrication of thin N-DLC coatings on the surface of electrospun PCL scaffolds. The effect of N-DLC coating deposition under various nitrogen pressures on the morphological, mechanical, physico-chemical, and biological properties of PCL scaffolds was investigated. It was established that an increase in nitrogen pressure in the range from 5 × 10−3 to 5 × 10−1 Pa results in up to a 10-fold increase in the nitrogen content and a 2-fold increase in the roughness of the PCL fiber surface. These factors provided the conditions for the enhanced adhesion and proliferation of human mesenchymal stem cells (MMSCs) on the surface of the modified PCL scaffolds. Importantly, the preservation of N-DLC coating properties determines the shelf life of a coated medical device. The elemental composition, tensile strength, and surface human MMSC adhesion were studied immediately after fabrication and after 6 months of storage under normal conditions. The enhanced MMSC adhesion was preserved after 6 months of storage of the modified PCL-based scaffolds under normal conditions.
Open AccessNitrogen-Doped Diamond-like Coatings for Long-Term Enhanced Cell Adhesion on Electrospun Poly(ε-caprolactone) Scaffold Surfaces
Electrospun poly(ε-caprolactone) (PCL)-based scaffolds are widely used in tissue engineering. However, low cell adhesion remains the key drawback of PCL scaffolds. It is well known that nitrogen-doped diamond-like carbon (N-DLC) coatings deposited on the surface of various implants are able to enhance their biocompatibility and functional properties. Herein, we report the utilization of the pulsed vacuum arc deposition (PVAD) technique for the fabrication of thin N-DLC coatings on the surface of electrospun PCL scaffolds. The effect of N-DLC coating deposition under various nitrogen pressures on the morphological, mechanical, physico-chemical, and biological properties of PCL scaffolds was investigated. It was established that an increase in nitrogen pressure in the range from 5 × 10−3 to 5 × 10−1 Pa results in up to a 10-fold increase in the nitrogen content and a 2-fold increase in the roughness of the PCL fiber surface. These factors provided the conditions for the enhanced adhesion and proliferation of human mesenchymal stem cells (MMSCs) on the surface of the modified PCL scaffolds. Importantly, the preservation of N-DLC coating properties determines the shelf life of a coated medical device. The elemental composition, tensile strength, and surface human MMSC adhesion were studied immediately after fabrication and after 6 months of storage under normal conditions. The enhanced MMSC adhesion was preserved after 6 months of storage of the modified PCL-based scaffolds under normal conditions.
- Open Access
Pulsed Vacuum Arc Deposition of Nitrogen-Doped Diamond-like Coatings for Long-Term Hydrophilicity of Electrospun Poly(ε-caprolactone) Scaffolds
The surface hydrophobicity of poly(ε-caprolactone) electrospun scaffolds prevents their interactions with cells and tissue integration. Although plasma treatment of scaffolds enhances their hydrophilicity, this effect is temporary, and the hydrophobicity of the scaffolds is restored in about 30 days. In this communication, we report a method for hydrophilization of poly(ε-caprolactone) electrospun scaffolds for more than 6 months. To that end, diamond-like coating was deposited on the surface of the scaffolds in a nitrogen atmosphere using pulsed vacuum arc deposition with sputtering of graphite target. This approach allows for a single-side hydrophilization of the scaffold (water contact angle of 22 ± 3° vs. 126 ± 2° for pristine PCL scaffold) and preserves its structure. With increased nitrogen pressure in the chamber, sp3-hybridized carbon content decreased twice (sp2/sp3 ratio decreased from 1.06 to 0.52), which demonstrates the possibility of tailoring the content of carbon in sp2 and sp3 hybridization state. Nitrogen content in the deposited coatings was found at 16.1 ± 0.9 at.%. In vitro tests with fibroblast cell culture did not reveal any cytotoxic compounds in sample extracts.
Open AccessPulsed Vacuum Arc Deposition of Nitrogen-Doped Diamond-like Coatings for Long-Term Hydrophilicity of Electrospun Poly(ε-caprolactone) Scaffolds
The surface hydrophobicity of poly(ε-caprolactone) electrospun scaffolds prevents their interactions with cells and tissue integration. Although plasma treatment of scaffolds enhances their hydrophilicity, this effect is temporary, and the hydrophobicity of the scaffolds is restored in about 30 days. In this communication, we report a method for hydrophilization of poly(ε-caprolactone) electrospun scaffolds for more than 6 months. To that end, diamond-like coating was deposited on the surface of the scaffolds in a nitrogen atmosphere using pulsed vacuum arc deposition with sputtering of graphite target. This approach allows for a single-side hydrophilization of the scaffold (water contact angle of 22 ± 3° vs. 126 ± 2° for pristine PCL scaffold) and preserves its structure. With increased nitrogen pressure in the chamber, sp3-hybridized carbon content decreased twice (sp2/sp3 ratio decreased from 1.06 to 0.52), which demonstrates the possibility of tailoring the content of carbon in sp2 and sp3 hybridization state. Nitrogen content in the deposited coatings was found at 16.1 ± 0.9 at.%. In vitro tests with fibroblast cell culture did not reveal any cytotoxic compounds in sample extracts.
- Open Access
DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility
In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties and cytotoxicity of the membranes modified under various conditions were studied. It was found that DLC coatings do not affect membrane microstructure, preserving its crystal structure as well as its high strength and elongation. It was revealed that an increase in the capacitor storage voltage results in the rise in sp2- and sp-hybridized carbon concentration, which makes it possible to control the chemical structure and surface energy of the modified surface. The experiments with 3T3L1 fibroblasts showed no toxic effects of the materials extracts.
Open AccessDLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility
In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties and cytotoxicity of the membranes modified under various conditions were studied. It was found that DLC coatings do not affect membrane microstructure, preserving its crystal structure as well as its high strength and elongation. It was revealed that an increase in the capacitor storage voltage results in the rise in sp2- and sp-hybridized carbon concentration, which makes it possible to control the chemical structure and surface energy of the modified surface. The experiments with 3T3L1 fibroblasts showed no toxic effects of the materials extracts.