Thiago Wanderley Matos De Abreu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thiago Wanderley Matos De Abreu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Françoise S. Lucas
Laboratoire Eau Environnement et Systèmes Urbains (Leesu), Université Paris-Est Créteil, École des Ponts ParisTech, 61 Avenue du Général de Gaulle, 94010 Créteil, France
2 shared publications - Sami Souihi
Laboratory of Images, Signals and Intelligent Systems (LiSSi), TincNET Research Team, Paris-East Crteil University, Crteil, France
2 shared publications - Arthur Guillot Le Goff
Laboratoire Eau Environnement et Systèmes Urbains (Leesu), Université Paris-Est Créteil, École des Ponts ParisTech, 61 Avenue du Général de Gaulle, 94010 Créteil, France
1 shared publication - Aurélie Janne
Syndicat Marne Vive, Maison de la Nature, 77 quai de la Pie, Saint-Maur-des-Fossés, 94100 Paris, France
1 shared publication - Brigitte Vinçon-Leite
Laboratoire Eau, Environnement, Systèmes Urbains (LEESU), École Nationale des Ponts et Chaussées, Marne-la-Vallée, France
1 shared publication - Claire Therial
Laboratoire Eau Environnement et Systèmes Urbains (Leesu), Université Paris-Est Créteil, École des Ponts ParisTech, 61 Avenue du Général de Gaulle, 94010 Créteil, France
1 shared publication
Latest Publications
- Open Access
Long-Term Stability of Low-Cost IoT System for Monitoring Water Quality in Urban Rivers
Monitoring water quality in urban rivers is crucial for water resource management since point and non-point source pollution remain a major challenge. However, traditional water quality monitoring methods are costly and limited in frequency and spatial coverage. To optimize the monitoring, techniques such as modeling have been proposed. These methods rely on networks of low-cost multiprobes integrated with IoT networks to offer continuous real-time monitoring, with sufficient spatial coverage. But challenges persist in terms of data quality. Here, we propose a framework to verify the reliability and stability of low-cost sensors, focusing on the implementation of multiparameter probes embedding six sensors. Various tests have been developed to validate these sensors. First of all, a calibration check was carried out, indicating good accuracy. We then analyzed the influence of temperature. This revealed that for the conductivity and the oxygen sensors, a temperature compensation was required, and correction coefficients were identified. Temporal stability was verified in the laboratory and in the field (from 3 h to 3 months), which helped identify the frequency of maintenance procedures. To compensate for the sensor drift, weekly calibration and cleaning were required. This paper also explores the feasibility of LoRa technology for real-time data retrieval. However, with the LoRa gateways tested, the communication distance with the sensing device did not exceed 200 m. Based on these results, we propose a validation method to verify and to assure the performance of the low-cost sensors for water quality monitoring.
Open AccessLong-Term Stability of Low-Cost IoT System for Monitoring Water Quality in Urban Rivers
Monitoring water quality in urban rivers is crucial for water resource management since point and non-point source pollution remain a major challenge. However, traditional water quality monitoring methods are costly and limited in frequency and spatial coverage. To optimize the monitoring, techniques such as modeling have been proposed. These methods rely on networks of low-cost multiprobes integrated with IoT networks to offer continuous real-time monitoring, with sufficient spatial coverage. But challenges persist in terms of data quality. Here, we propose a framework to verify the reliability and stability of low-cost sensors, focusing on the implementation of multiparameter probes embedding six sensors. Various tests have been developed to validate these sensors. First of all, a calibration check was carried out, indicating good accuracy. We then analyzed the influence of temperature. This revealed that for the conductivity and the oxygen sensors, a temperature compensation was required, and correction coefficients were identified. Temporal stability was verified in the laboratory and in the field (from 3 h to 3 months), which helped identify the frequency of maintenance procedures. To compensate for the sensor drift, weekly calibration and cleaning were required. This paper also explores the feasibility of LoRa technology for real-time data retrieval. However, with the LoRa gateways tested, the communication distance with the sensing device did not exceed 200 m. Based on these results, we propose a validation method to verify and to assure the performance of the low-cost sensors for water quality monitoring.
- Open Access
Evaluating the Performance of Machine Learning Approaches to Predict the Microbial Quality of Surface Waters and to Optimize the Sampling Effort
Exposure to contaminated water during aquatic recreational activities can lead to gastrointestinal diseases. In order to decrease the exposure risk, the fecal indicator bacteria Escherichia coli is routinely monitored, which is time-consuming, labor-intensive, and costly. To assist the stakeholders in the daily management of bathing sites, models have been developed to predict the microbiological quality. However, model performances are highly dependent on the quality of the input data which are usually scarce. In our study, we proposed a conceptual framework for optimizing the selection of the most adapted model, and to enrich the training dataset. This frameword was successfully applied to the prediction of Escherichia coli concentrations in the Marne River (Paris Area, France). We compared the performance of six machine learning (ML)-based models: K-nearest neighbors, Decision Tree, Support Vector Machines, Bagging, Random Forest, and Adaptive boosting. Based on several statistical metrics, the Random Forest model presented the best accuracy compared to the other models. However, 53.2 ± 3.5% of the predicted E. coli densities were inaccurately estimated according to the mean absolute percentage error (MAPE). Four parameters (temperature, conductivity, 24 h cumulative rainfall of the previous day the sampling, and the river flow) were identified as key variables to be monitored for optimization of the ML model. The set of values to be optimized will feed an alert system for monitoring the microbiological quality of the water through combined strategy of in situ manual sampling and the deployment of a network of sensors. Based on these results, we propose a guideline for ML model selection and sampling optimization.
Open AccessEvaluating the Performance of Machine Learning Approaches to Predict the Microbial Quality of Surface Waters and to Optimize the Sampling Effort
Exposure to contaminated water during aquatic recreational activities can lead to gastrointestinal diseases. In order to decrease the exposure risk, the fecal indicator bacteria Escherichia coli is routinely monitored, which is time-consuming, labor-intensive, and costly. To assist the stakeholders in the daily management of bathing sites, models have been developed to predict the microbiological quality. However, model performances are highly dependent on the quality of the input data which are usually scarce. In our study, we proposed a conceptual framework for optimizing the selection of the most adapted model, and to enrich the training dataset. This frameword was successfully applied to the prediction of Escherichia coli concentrations in the Marne River (Paris Area, France). We compared the performance of six machine learning (ML)-based models: K-nearest neighbors, Decision Tree, Support Vector Machines, Bagging, Random Forest, and Adaptive boosting. Based on several statistical metrics, the Random Forest model presented the best accuracy compared to the other models. However, 53.2 ± 3.5% of the predicted E. coli densities were inaccurately estimated according to the mean absolute percentage error (MAPE). Four parameters (temperature, conductivity, 24 h cumulative rainfall of the previous day the sampling, and the river flow) were identified as key variables to be monitored for optimization of the ML model. The set of values to be optimized will feed an alert system for monitoring the microbiological quality of the water through combined strategy of in situ manual sampling and the deployment of a network of sensors. Based on these results, we propose a guideline for ML model selection and sampling optimization.