IMIbsen Montalvan

Ibsen Montalvan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ibsen Montalvan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An expanded high throughput RT-PCR assay to rapidly identify all known SARS-CoV-2 variants of concern using melting temperature coding

    by Padmapriya P Banada, Raquel Green, Sukalyani Banik, Deanna Streck, Ibsen Montalvan, Robert Reiss, Robert Jones, Salvatore A. E. Marras, Soumitesh Chakravorty, David Alland

    Background: The rapid emergence of new vaccine-resistant SARS-CoV-2 variants of concern (VOC) requires an equally rapid deployment of diagnostic tests to specifically identify each VOC as soon as it arises. Here, we report an expanded version of our previously described sloppy molecular beacon (SMB) Alpha/Beta/Gamma RT-PCR melting temperature (Tm) signature-based assay, which now includes modifications that allow specific detection of Delta (B.1.617.2) and Omicron (B.1.529) VOCs. Methods: We developed a dual SMB assay (SMB-452), which targeted the T22917G (L452R) mutation in the SARS-CoV-2 spike protein to specifically detect the Delta VOC. We also identified a Tm profile in our existing SMB-501 and SMB-484 assays (which detect mutations in codons 501 and 484 of the SARS-CoV-2 spike protein, respectively) that differentiate the Omicron-specific N501Y (A23063T) and E484A (A23013C) mutations from both wild type (WT) and other VOCs. The entire six SMB three-codon assay was tested using reference SARS-CoV-2 RNAs. The assay was then validated using clinical samples from COVID-19 patients tested with a LightCycler 480 (LC480) (74 samples), Bio-Rad CFX96 (34 samples), Rotor-Gene Q (Qiagen) (34 samples) and an ABI-7500 (34 samples) RT-PCR instruments. Six SMB Tm results were then inputted into an Excel Analysis tool to generate specific VOC identifications. Results: The limit of detection (LOD) for the new SMB-452 assay, which specifically identified the Delta variant was 1 genomic equivalent (GE) per reaction. The LODs of the SMB-501 and SMB-484 assays, which detect Omicron were 100 and 10 3 GE respectively. Clinical validation of the 3-codon assay in the LC480 instrument showed the assay detected 94% of the samples as WT or VOCs in clinical samples and 6% of the tests producing indeterminate results. None of the samples were incorrectly identified as WT or as a different VOC. Thus, excluding samples with indeterminant results, the assay was 100% sensitive and 100% specific compared to sequencing. There was also 100% concordance between the LC480, BioRad, ABI and Qiagen results, excluding negative or indeterminate results; however, the Qiagen assay had significantly more indeterminates than the other assays. Conclusion: This new assay can serve as a robust diagnostic tool for selecting appropriate monoclonal antibody therapy and rapid VOC surveillance.

  • Open Access

    Sample collection and transport strategies to enhance yield, accessibility, and biosafety of COVID-19 RT-PCR testing

    by Padmapriya Banada, David Elson, Naranjargal Daivaa, Claire Park, Samuel Desind, Ibsen Montalvan, Robert Kwiatkowski, Soumitesh Chakravorty, David Alland, Yingda L. Xie

    Introduction. Non-invasive sample collection and viral sterilizing buffers have independently enabled workflows for more widespread COVID-19 testing by reverse-transcriptase polymerase chain reaction (RT-PCR). Gap statement. The combined use of sterilizing buffers across non-invasive sample types to optimize sensitive, accessible, and biosafe sampling methods has not been directly and systematically compared. Aim. We aimed to evaluate diagnostic yield across different non-invasive samples with standard viral transport media (VTM) versus a sterilizing buffer eNAT- (Copan diagnostics Murrieta, CA) in a point-of-care diagnostic assay system. Methods. We prospectively collected 84 sets of nasal swabs, oral swabs, and saliva, from 52 COVID-19 RT-PCR-confirmed patients, and nasopharyngeal (NP) swabs from 37 patients. Nasal swabs, oral swabs, and saliva were placed in either VTM or eNAT, prior to testing with the Xpert Xpress SARS-CoV-2 (Xpert). The sensitivity of each sampling strategy was compared using a composite positive standard. Results. Swab specimens collected in eNAT showed an overall superior sensitivity compared to swabs in VTM (70 % vs 57 %, P=0.0022). Direct saliva 90.5 %, (95 % CI: 82 %, 95 %), followed by NP swabs in VTM and saliva in eNAT, was significantly more sensitive than nasal swabs in VTM (50 %, PP=0.0012) and oral swabs in VTM (50 %, PPConclusion. Saliva and eNAT sterilizing buffer can enhance safe and sensitive detection of COVID-19 using point-of-care GeneXpert instruments.