Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhanguang Wang has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Parametric Study on an Integrated Sleeve Mortise-and-Tenon Steel–Timber Composite Beam–Column Joints

    by Zhanguang Wang, Weihan Yang, Zhenyu Gao, Jianhua Shao

    To address the limitations of traditional timber mortise-and-tenon joints, particularly their low pull-out resistance and rapid stiffness degradation under cyclic loading, this study proposes a novel integrated sleeve mortise-and-tenon steel–timber composite beam–column joint. Building upon prior experimental validation and numerical model verification, a comprehensive parametric study was conducted to systematically investigate the influence of key geometric parameters on the seismic performance of the joint. The investigated parameters included beam sleeve thickness (1–10 mm), sleeve length (150–350 mm), bolt diameter (4–16 mm), and the dimensions and thickness of stiffeners. The results indicate that a sleeve thickness of 2–3 mm yields the optimal overall performance: sleeves thinner than 2 mm are prone to yielding, while those thicker than 3 mm induce stress concentration in the timber beam. A sleeve length of approximately 250 mm provides the highest initial stiffness and a ductility coefficient exceeding 4.0, representing the best seismic behavior. Bolt diameters within the range of 8–10 mm produce full and stable hysteresis loops, effectively balancing load-carrying capacity and energy dissipation; smaller diameters lead to pinching failure, whereas larger diameters trigger premature plastic deformation in the timber. Furthermore, stiffeners with a width of 40 mm and a thickness of 2 mm effectively enhance joint stiffness, promote a uniform stress distribution, and mitigate local damage. The optimized joint configuration demonstrates excellent ductility, stable hysteretic behavior, and a high load capacity, providing a robust technical foundation for the design and practical application of advanced steel–timber composite connections.

  • Experimental study and finite element analysis on mechanical performance of the steel tube column filled with aluminium foam under eccentric compression

    by Dongmei Li, Jianhua Shao, Nan Wang, Hongxuan Xu, Zhanguang Wang, Jing Huang, Xuan Zhang

    To investigate the compressive deformation mode and flexural mechanical performance of steel tube columns filled with aluminium foam, a series of corresponding experiments under the quasi-static eccentric compressive conditions were performed to obtain the failure deformation diagram, load-deflection curve and load-strain relationship. Based on the experimental study, A finite element model was established to analyze the mechanical performance of steel tube columns filled with aluminum foam under different loading eccentric distances. The results show that the restrained bending deformation was more pronounced in the steel tube column filled with aluminum foam, and this deformation significantly improved the overall mechanical performance as the porosity of the aluminum foam decreased. Compared with the pure steel column, the ultimate loads of the aluminium foam-filled steel tube column with porosities of 90%, 80% and 70% were increased by 87.13%, 93.41%, and 104.11%, respectively. The tensile or compressive strains of the pure steel tube column and that filled with aluminium foam respectively appeared symmetric and asymmetric phenomena because the failure deformation mode of the steel tube column was influenced by filling aluminium foam. Compared with axial compression, the ultimate vertical loads of the aluminium foam-filled steel tube column with loading eccentricities of 30 mm, 50 mm, 100 mm and 150 mm decreased by 48.78%, 60.35%, 80.19% and 88.61%. The steel tube columns filled with aluminium foam under axial compressive action and eccentric load appeared different failure modes, which were respectively the progressive crushing symmetrical deformation and bending deformation. The corresponding failure phenomena of these tubes were observed to transition from local buckling occurring at the loading or fixed end to overall bending deformation along the column length with the gradual increase of eccentricity. Furthermore, the bending moment value of the steel tube column filled with aluminium foam obtained from the experiment under different loading eccentric distances increases with the decrease of load eccentricity.


  • Open Access

    Experimental and Finite Element Study on Wooden Joints Strengthened by Detachable Steel Sleeves

    by Jiajun Gao, Jianhua Shao, Yong Wang, Anxiang Feng, Zhanguang Wang, Hongxuan Xu, Yangfa Zhu, Boshi Ma

    We designed detachable steel sleeves to reinforce wooden joints and improve their integrity under earthquake action and investigated their mechanical properties. Monotonic bending tests were performed on a half-tenon pure wooden joint and a joint strengthened by a detachable steel sleeve. More obvious tenon pulling-out failure was observed in the pure wood joint; in comparison, only slight extrusion fracture of wooden beams and extrusion deformation of steel sleeves occurred in the wood joint reinforced by a detachable steel sleeve. Our test results showed that the initial rotational stiffness of the strengthened joint, JG1, was increased by 495.4% compared with that of the unstrengthened joint, JG0. The yield bending moment increased by 425.9%, and the ultimate bending moment increased by 627.5%, which indicated that the mechanical performance was significantly improved when the joint was reinforced by a detachable steel sleeve. Numerical simulations of different components were performed with finite element analysis software to analyze the mechanical performance of the reinforced joint. It was found that the stiffness and ultimate flexural performance of the joint could be increased by setting stiffeners on the steel sleeve and connecting the wooden column with self-tapping screws. The results of the tests were compared with those obtained through finite element analysis, and a high degree of accuracy was achieved, which could provide a theoretical basis for the reinforcement of timber structural buildings.

  • Open Access

    Experiment and Finite Element Research on Mechanical Performance of Thin-Walled Steel–Wood Composite Columns Under Eccentric Compression

    by Yangfa Zhu, Jianhua Shao, Anxiang Feng, Xianglan Li, Zhanguang Wang, Hongxuan Xu, Jiajun Gao, Boshi Ma

    In order to conduct an in-depth and exhaustive investigation into the mechanical properties of steel tubes filled with wood, a thin-walled steel–wood composite column was elaborately designed. The damage progression, failure mode, and mechanical performance of this column under eccentric compression were systematically investigated through both experimental research and finite element simulations. The impacts of different numbers of bolts on the mechanical properties of the composite column were minutely analyzed, and the test results of composite columns were compared with the pure steel pipe column under the same experimental conditions. It was clearly observed that the pure thin-walled steel pipe specimen was highly susceptible to elastic instability under eccentric compression, and the high-strength and high-ductility potential of structural steel was not fully developed. However, after filling with wood and applying bolt restraints, the greater the number of bolts in the specimen of thin-walled steel–wood composite column under the identical eccentricity condition, the higher the ultimate load-bearing capacity. Specifically, the ultimate load-bearing capacity of the columns filled with wood increased by 77.78–114% in comparison with that of the pure steel pipe column. Through a meticulous comparison between the test and finite element analysis results, the error was ascertained to be in the range of 4.9–11.1%. In addition, filling the thin-walled steel tube with wood and restraining it with bolts can effectively enhance the lateral deformation resistance of the specimens, and the reduction rate of lateral deflection exceeded 50%. Moreover, the greater the number of filling bolts, the smaller the strain of components subjected to the eccentric compression occurred, and the better the mechanical properties.


  • Development and performance of a wood adhesive with Camellia oleifera protein doped with soy oligopeptide

    by Jiankun Liang, De Li, Longxu Wu, Xue Deng, Chuchu Chen, Tong Meng, Huali Li, Zhanguang Wang, Zhigang Wu

    A high-performance wood adhesive was successfully developed by incorporating soybean oligopeptides into Camellia oleifera protein through a combination of degradation and epoxy resin crosslinking techniques. The results showed that the presence of oligopeptides boosted the creation of more active functional groups in the degradation liquid system. This process enhanced the adhesive’s initial viscosity and overall stability. As a result, the adhesive’s performance was significantly improved, making the bond more robust and long-lasting. However, a notable drawback was observed: the storage duration of the adhesive was shortened from 10 h to 3.5 h. Despite this limitation, the adhesive exhibited several advantageous properties, including a high curing reaction rate, a relatively low curing temperature, and excellent thermal stability. Additionally, the prepared adhesive demonstrated superior bonding strength and outstanding water resistance, making it a promising alternative for various wood-based applications.

  • Open Access

    Experimental and Numerical Study on Mechanical Performance of Half-Tenon Beam–Column Joint Under Different Reinforcement of Energy Dissipation Plate and Steel Sleeve

    by Dongmei Li, Jianhua Shao, Anxiang Feng, Zhanguang Wang, Hongxuan Xu, Jinning Gao, Shengyu Chen

    Two types of reinforcing the half-tenon wood joints, one reinforced with an energy dissipation plate (SW-1) and the other by a steel sleeve with energy dissipation plate (SW-2), were designed. The pure wood beam–column joint specimen SW-0, specimen SW-1 and specimen SW-2 were experimented by the monotonic loading test, and the corresponding failure mode of joints and load–displacement curve were obtained. Based on the reliability of the verified finite element numerical model, the impact of thickness of the energy dissipation plate on the seismic performance of the SW-2 joint was analyzed. The research results show that the SW-0 and SW-1 joints exhibited significant tenon pulling phenomena, while the SW-2 joint did not show this phenomenon. The initial stiffness of the joints is significantly improved after reinforcement, and the initial stiffness of the SW-1 and SW-2 specimens is 2.64 and 7.24 times that of the SW-0 specimen, respectively. The ultimate loads of specimens SW-0, SW-1 and SW-2 are, respectively, 2.8 kN, 6.2 kN and 24.9 kN. The enclosed area of hysteresis loop and the slope of skeleton curve gradually increase as the thickness of the energy dissipation plate increases, resulting in a significant enhancement in energy dissipation capacity. The ultimate bearing capacity of the joint and the slope of skeleton curve exhibit negligible variation when the thickness of energy dissipation plate exceeds 2.0 mm, and the corresponding optimal thickness is obtained as 2 mm.

  • Open Access

    Experimental and Numerical Simulation Study on the Mechanical Properties of Integrated Sleeve Mortise and Tenon Steel–Wood Composite Joints

    by Zhanguang Wang, Weihan Yang, Zhenyu Gao, Jianhua Shao, Dongmei Li

    In view of the application status and technical challenges of steel–wood composite joints in architecture, this paper proposes an innovative connection technology to solve issues such as susceptibility to pry-out at beam–column joints and low load-bearing capacity and to provide various reinforcement methods in order to meet the different structural requirements and economic benefits. By designing and manufacturing four groups of beam–column joint specimens with different reinforcement methods, including no reinforcement, structural adhesive and angle steel reinforcement, 4 mm thick steel sleeve reinforcement, and 6 mm thick steel sleeve reinforcement, monotonic loading tests and finite element simulations were carried out, respectively. This research found that unreinforced specimens and structural adhesive angle steel-reinforced joints exhibited obvious mortise and tenon compression deformation and, moreover, tenon pulling phenomena at load values of approximately 2 kN and 2.6 kN, respectively. However, the joint reinforced by a steel sleeve showed a significant improvement in the tenon pulling phenomenon and demonstrated excellent initial stiffness characteristics. The failure mode of the steel sleeve-reinforced joints is primarily characterized by the propagation of cracks at the edges of the steel plate and the tearing of the wood, but the overall structure remains intact. The initial rotational stiffness of the joints reinforced with angle steel and self-tapping screws, the joints reinforced with 4 mm thick steel sleeves, and the joints reinforced with 6 mm thick steel sleeves are 3.96, 6.99, and 13.62 times that of the pure wooden joints, while the ultimate bending moments are 1.97, 7.11, and 7.39 times, respectively. Using finite element software to simulate four groups of joints to observe their stress changes, the areas with high stress in the joints without sleeve reinforcement are mainly located at the upper and lower ends of the tenon, where the compressive stress at the upper edge of the tenon and the tensile stress at the lower flange are both distributed along the grain direction of the beam. The stress on the column sleeve of the joints reinforced with steel sleeves and bolts is relatively low, while the areas with high strain in the beam sleeve are mainly concentrated on the side with the welded stiffeners and its surroundings; the strain around the bolt holes is also quite noticeable.


  • Experimental Study on the Lateral Performance of Timber Frames with Different Forms of Column Base Joints

    by Bin Hu, Guangbin Pan, Yongzhong Mou, Jian Cai, Shengcan Lu, Zhanguang Wang, Ji Zhang


  • Open Access

    Study on Quasi-Static Axial Compression Performance and Energy Absorption of Aluminum Foam-Filled Steel Tubes

    by Zhanguang Wang, Jianhua Shao

    To study the axial compression performance of aluminum foam-filled steel tube and empty steel tube as objects, such tubes are studied in this paper, which explores the carrying capacity and deformation behavior of aluminum foam-filled steel tube with different lengths under a quasi-static axial load through experimental research. The carrying capacity, deformation behavior, stress distribution, and energy absorption characteristics of empty steel tubes and foam-filled steel tubes are compared through finite element numerical simulation. The results indicate that, compared with the empty steel tube, the aluminum foam-filled steel tube still presents a large residual carrying capacity after the axial force exceeds the ultimate load, and the whole compression process reflects steady-state compression. In addition, the axial and lateral deformation amplitudes of the foam-filled steel tube decrease significantly during the whole compression process. After filling the foam metal, the large stress area decreases and the energy absorption capacity improves.