TNThai An Nguyen

Thai An Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thai An Nguyen has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Application Entropy Weighting and Simple Additive Weighting Methods for Ranking Load in Microgrid

    by Thanh Khoa Nguyen, Thai An Nguyen, Huy Anh Quyen, Khoa Thanh Pham

    This paper presents the Entropy Weighting method combined with the Simple Additive Weighting (SAW) technique to determine the optimal load among multiple loads, serving the purposes of load ranking in a Microgrid system, taking into account the priority of supply reliability. Load ranking is essential for evaluating the importance level of each load in the power system, thereby enhancing the operational efficiency of the Microgrid. The Entropy Weighting method is employed to determine the objective weights of each criterion based on the degree of dispersion of the criteria in the decision matrix, followed by the application of the Simple Additive Weighting method to calculate the final priority weight of each load. This weighting approach is straightforward to implement and helps to minimize the subjectivity of decision-makers, thereby improving the reliability of the ranking results. The computational results, applied to the IEEE 16-bus Microgrid model, demonstrate the effectiveness of the proposed method.

  • Open Access

    A Study on Determining the Output Power of Wind Energy Generation Considering Uncertainty in Input Power Forecasting

    by Le Trung Tin Doan, Thai An Nguyen, Le Huu Tri Phan, Trong Nghia Le, Thi Thu Hien Huynh

    This paper presents a method for determining the output power of a wind power generation system under wind speed uncertainty. Hourly wind data collected in Hawaii, USA, is statistically modeled using four probability distribution functions: Weibull, Rayleigh, Log-normal, and Gamma. The distribution parameters are estimated via the Maximum Likelihood Estimation (MLE) method and subsequently applied to a Doubly-Fed Induction Generator (DFIG) model in MATLAB/Simulink to simulate power output variations based on probabilistically modeled wind speed. The fit quality of each distribution is assessed by calculating the Mean Absolute Error (MAE), Root Mean Square Error (RMSE), and the coefficient of determination (R²), in comparison to the empirical histogram. The results indicate that the two-parameter Weibull distribution best fits the measured data (MAE = 0.00708, RMSE = 0.0097, R² = 0.93), followed by the Gamma distribution. In contrast, the Rayleigh and Log-normal distributions exhibit significant deviations. When the Weibull parameters are applied to the DFIG model, the simulated weekly power output ranges from 0.96 MW to 1.37 MW, clearly illustrating the nonlinear relationship between wind speed and output power. The proposed approach thus provides a rigorous quantitative framework that links the probabilistic characteristics of wind to the actual power output range, thereby enhancing reliability in operational planning and mitigating risks in modern power systems.

  • Open Access

    Probability Distribution of Solar Radiation to Determine the Output Power of the PV System Under Uncertain Conditions

    by Duy Dung Nguyen, Thai An Nguyen, Tien Dat Tran, Van Dai Nguyen, Khoa Thanh Pham, Trong Nghia Le

    This study introduces a probabilistic modeling framework for solar irradiance that aims to enhance the output power stability of photovoltaic (PV) systems by explicitly accounting for the stochastic nature of solar radiation. Real – world irradiance measurements are first preprocessed and smoothed to remove noise and short – term fluctuations, thereby improving the reliability of statistical estimation. Three probability distributions Weibull, Beta, and Lognormal – are modeled, with their parameters estimated through the Maximum Likelihood Estimation (MLE) method. The suitability of each distribution is assessed using multiple statistical performance indicators, including Mean Squared Error (MSE), Root Mean Squared Error (RMSE), Mean Absolute Error (MAE), and the coefficient of determination (R²). Comparative analysis reveals that the Beta distribution provides the highest degree of fit and the lowest prediction error, making it the most appropriate model for representing the temporal variability of solar irradiance in the given dataset. Synthetic irradiance samples generated from the optimal distribution are subsequently integrated into a 250 kW grid – connected PV array model implemented in MATLAB/Simulink to evaluate power output characteristics under uncertain meteorological conditions. Simulation results confirm the method’s ability to capture dynamic fluctuations in solar energy availability and support robust power prediction. The proposed approach can assist in power system analysis, operational planning, and decision-making for PV integration, thereby contributing to improved grid stability and energy management strategies in renewable-rich environments.

  • Open Access

    Ranking load in microgrid based on fuzzy analytic hierarchy process and technique for order of preference by similarity to ideal solution algorithm for load shedding problem

    by Tung Giang Tran, Thai An Nguyen, Trong Nghia Le, Ngoc Au Nguyen, Thi Ngoc Thuong Huynh

    This paper proposes a method to rank the loads in the microgrid by means of a weight that combines the criteria together in terms of both technical and economic aspects. The fuzzy analytic hierarchy process technique for order of preference by similarity to ideal solution (fuzzy AHP TOPSIS) algorithm is used to calculate this combined weight. The criteria to be considered are load importance factor (LIF), voltage electrical distance (VED) and voltage sensitivity index (VSI). The fuzzy algorithm helps to fuzzy the judgment matrix of the analytic hierarchy process (AHP) method, making it easier to compare objects with each other and remove the uncertainty of the AHP method. The technique for order of preference by similarity to ideal solution (TOPSIS) algorithm is used to normalize the decision matrix, determine the positive and negative ideal solutions to calculate the index of proximity to the ideal solution, and finally rank all the alternatives. The combination of fuzzy AHP and TOPSIS algorithms is the optimal combination for decision making and ranking problems in a multi-criteria environment. The 19-bus microgrid system is applied to calculate and demonstrate the effectiveness of the proposed method.


  • Open Access

    Optimize Ranking and Load Shedding in Microgrid Considering Improved Analytic Hierarchy Process Algorithm and Power Stability Index

    by Trong Nghia Le, Hoang Minh Vu Nguyen, Thai An Nguyen, Trieu Tan Phung, Thi Thu Hien Huynh, Quang Tien Nguyen

    This paper proposes a load shedding model for the island microgrid based on the ranking of loads and the power stability index (PSI). Loads are ranked based on the improved analytic hierarchy process (AHP) algorithm. Real‐time measurement systems have the function of collecting data for very important, important, and less‐important loads at each bus load. From this data, the improved AHP method is applied to rank the loads. The advantage of this method is that the subjectivity is eliminated and not depending on the expertise of the system operator when implementing the traditional AHP method. Besides, the minimum amount of load shedding power is calculated, taking into account both primary and secondary control methods. The objective is to minimize the impact on power consumers and ensure that the frequency returns to an acceptable range. In addition, when implementing load shedding, voltage quality, and stability are considered. The PSI serves as a crucial parameter for assessing the voltage stability of microgrid buses. This index is combined with load ranking weights to obtain combined weights for the load shedding plan. Consequently, the proposed load shedding plan prioritizes minimizing damage to customers, improving voltage quality and stability, and ensuring frequency is within permissible limits. The 16‐bus microgrid system is applied to compare with traditional methods and to prove the efficiency of the suggested technique.


  • Open Access

    Load Shedding in Microgrids with Dual Neural Networks and AHP Algorithm

    by L. T. H. Nhung, T. T. Phung, H. M. V. Nguyen, T. N. Le, T. A. Nguyen, T. D. Vo

    This paper proposes a new load shedding method based on the application of a Dual Neural Network (NN). The combination of a Back-Propagation Neural Network (BPNN) and of Particle Swarm Optimization (PSO) aims to quickly predict and propose a load shedding strategy when a fault occurs in the microgrid (MG) system. The PSO algorithm has the ability to search and compare multiple points, so the proposed NN training method helps determine the link weights faster and stronger. As a result, the proposed method saves training time and achieves higher accuracy. The Analytic Hierarchy Process (AHP) algorithm is applied to rank the loads based on their importance factor. The results of the ratings of the loads serve as a basis for constructing the load shedding strategies of a NN combined with the PSO algorithm (ANN-PSO). The proposed load shedding method is tested on an IEEE 25-bus 8-generator MG power system. The simulation results show that the frequency recovery of the power system is positive. The proposed neural network adapts well to the simulated data of the system and achieves high performance in fault prediction.


  • Open Access

    Load Shedding in Microgrid System with Combination of AHP Algorithm and Hybrid ANN-ACO Algorithm

    by Huy Anh Quyen, Tan Phung Trieu, Trong Nghia Le, Thai An Nguyen, Thi Ngoc Thuong Huynh

    This paper proposes a new load shedding method based on the application of intelligent algorithms, the process of calculating and load shedding is carried out in two stages. Stage-1 uses a backpropagation neural network to classify faults in the system, thereby determining whether or not to shed the load in that particular case. Stage-2 uses an artificial neural network combined with an ant colony algorithm (ANN-ACO) to determine a load shedding strategy. The AHP algorithm is applied to propose load shedding strategies based on ranking the importance of loads in the system. The proposed method in the article helps to solve the integrated problem of load shedding, classifying the fault to determine whether or not to shedding the load and proposing a correct strategy for shedding the load. The IEEE 25-bus 8-generator power system is used to simulate and test the effectiveness of the proposed method, the results show that the frequency of recovery is good in the allowable range.


  • Open Access

    Distributed Load Shedding considering the Multicriteria Decision-Making Based on the Application of the Analytic Hierarchy Process

    by Nghia T. Le, An T. Nguyen, Thi Trang Hoang, Hoang Minh Vu Nguyen, Anh H. Quyen, Binh T. T. Phan

    This paper shows an analytic hierarchy process (AHP) algorithm-based approach for load shedding based on the coordination of the load importance factor (LIF), the reciprocal phase angle sensitivity (RPAS), and the voltage electrical distance (VED) to rank the load buses. This problem is important from a power system point of view, and the AHP method is able to support the decision-making process in a simple and intuitive way in a three-criterion environment. This satisfies the multicriteria decision-making to meet economic-technical aspects. The ranking and distributed shedding power at each demand load bus are based on this combined weight. The smaller overall weights of the load buses show the lesser importance of the load bus, the smaller reciprocal phase angle sensitivity, and the closer voltage electrical distance. Therefore, these load buses cut a larger amount of capacity, and vice versa. By considering the generator control, the load shedding consists of the primary and secondary control features of the generators to minimize the load shedding capacity and restore the system frequency value back to the allowable range. The efficiency of the suggested load-shedding scheme was verified via the comparison with the under-frequency load shedding (UFLS). The latter result is that the load shedding power of the suggested approach is 22.64% lower than the UFLS method. The case studies are experienced on the IEEE 9-generator; the 37-bus system has proven its effectiveness.


  • Application of AHP Algorithm to Coordinate Multiple Load Shedding Factors in the Microgrid

    by An Thai Nguyen, Trong Nghia Le, Huy Anh Quyen, Minh Vu Nguyen Hoang, Phung Bao Long Nguyen

    The rapidly drop of frequency in the microgrid (MG) system when it operates under island operation has caused frequency stability problems. In case, generators and renewable energy sources cannot supply enough power to restore the frequency, the load shedding will be proceeded. This paper proposes the load shedding method based on the coordinate multiple load shedding factors when the MG system operates in island mode. This proposed method carries out an approach through two main steps. Firstly, the optimal amount of load shedding power considering renewable energy sources and the ability to adjust the primary and secondary frequencies of the generator is calculated to restore the frequency to the allowed range. Next, distributing the optimal load shedding power for each bus is based on the combination of different criteria to meet the economic and technical goals. On the technical side, this paper also considers two criteria about the voltage distance, and the voltage sensitivity index. These two criteria contribute to reducing voltage drop and improving voltage stability when the microgrid operates in island mode. From the economic perspective, it considers the load importance factor, thereby minimizing the economic losses caused by load shedding. The AHP algorithm is applied in this paper to determine the importance of loads and the importance of the different criteria when they are combined. The effectiveness of the proposed method is demonstrated through simulation of IEEE 16-bus microgrid with 6-source.