Baolong Phung Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Baolong Phung Nguyen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yuan-Kang Wu
National Chung-Cheng University, Chiayi, Taiwan
4 shared publications - Manh-Hai Pham
Electric Power University, Hanoi, Vietnam
3 shared publications - Huy Anh Quyen
Ho Chi Minh City University of Technology and Education, Vietnam
2 shared publications - Trong Nghia Le
Ho Chi Minh City University of Technology and Education, Vietnam
2 shared publications Tung Trinh Duc
National Chung-Cheng University,Departmenrt of Electrical Engineering,Chiayi,Taiwan
2 shared publicationsYuan-Kang Wu
National Chung-Cheng University,Departmenrt of Electrical Engineering,Chiayi,Taiwan
2 shared publications
Latest Publications
- Open Access
Coordinated Frequency Regulation between DFIG-VSWTs and BESS Hybrid Systems
As the utilization of wind power systems continues to increase, reducing overall system inertia, there is a consequential negative impact on the power system’s ability to regulate frequency. Consequently, this study focuses on examining the fast-frequency regulation in high penetration of wind power, especially doubly fed induction generators—the most commonly installed wind turbine type, and an energy storage system installed in the wind farm. This study proposes a coordinated control of wind turbine generators and battery energy storage systems that provides fast-frequency regulation to the system while simultaneously ensuring the safety of the battery. Firstly, the fast-frequency regulation capability of the wind turbine will be studied. Secondly, primary frequency control of the battery energy storage system considering adaptive droop control based on state of charge is proposed to prevent both over-charging and over-discharging of the battery. Finally, this study proposed a coordinated fast-frequency regulation approach for the hybrid wind-storage system, which is evaluated under various wind speed scenarios. This approach involves a detailed analysis of the operational characteristics of the wind turbine generators to ensure optimal performance. The proposed method is validated through simulation using a MATLAB model of the wind-storage system, and comparative results with alternative control methods confirm the effectiveness of the proposed approach in raising the frequency nadir and avoiding the secondary frequency dip.
Open AccessCoordinated Frequency Regulation between DFIG-VSWTs and BESS Hybrid Systems
As the utilization of wind power systems continues to increase, reducing overall system inertia, there is a consequential negative impact on the power system’s ability to regulate frequency. Consequently, this study focuses on examining the fast-frequency regulation in high penetration of wind power, especially doubly fed induction generators—the most commonly installed wind turbine type, and an energy storage system installed in the wind farm. This study proposes a coordinated control of wind turbine generators and battery energy storage systems that provides fast-frequency regulation to the system while simultaneously ensuring the safety of the battery. Firstly, the fast-frequency regulation capability of the wind turbine will be studied. Secondly, primary frequency control of the battery energy storage system considering adaptive droop control based on state of charge is proposed to prevent both over-charging and over-discharging of the battery. Finally, this study proposed a coordinated fast-frequency regulation approach for the hybrid wind-storage system, which is evaluated under various wind speed scenarios. This approach involves a detailed analysis of the operational characteristics of the wind turbine generators to ensure optimal performance. The proposed method is validated through simulation using a MATLAB model of the wind-storage system, and comparative results with alternative control methods confirm the effectiveness of the proposed approach in raising the frequency nadir and avoiding the secondary frequency dip.
- Open Access
Novel Fuzzy Logic Controls to Enhance Dynamic Frequency Control and Pitch Angle Regulation in Variable-Speed Wind Turbines
This study introduced a novel control approach based on fuzzy logic control (FLC) to enhance the frequency regulation capacity of variable-speed wind turbines (VSWTs). The proposed method integrates FLC within droop and inertia control loops. Real-time measurements of the system frequency and the rate of change of frequency (ROCOF) serve as inputs to the FLC, enabling the method to improve the frequency response by VSWTs. In addition, the method employs FLC for pitch angle frequency control, optimizing reserve power for frequency regulation under varying wind speed levels. The innovative aspect of this study lies in the simultaneous application of FLC to pitch angle frequency control and droop/inertia control, leading to the enhanced frequency regulation capability of VSWTs and smoother operation across a range of wind speeds. Compared with traditional methods, the proposed approach provides a comprehensive and effective solution to the challenges associated with frequency regulation in VSWTs. Through simulations across different wind speed scenarios, the proposed control method demonstrated the best performance among various mature methods, highlighting the efficacy of the proposed method on the frequency regulation of VSWTs under different wind speeds. This study’s findings highlight the potential of the proposed FLC-based method to optimize frequency regulation and contribute to more reliable and efficient wind energy systems.
Open AccessNovel Fuzzy Logic Controls to Enhance Dynamic Frequency Control and Pitch Angle Regulation in Variable-Speed Wind Turbines
This study introduced a novel control approach based on fuzzy logic control (FLC) to enhance the frequency regulation capacity of variable-speed wind turbines (VSWTs). The proposed method integrates FLC within droop and inertia control loops. Real-time measurements of the system frequency and the rate of change of frequency (ROCOF) serve as inputs to the FLC, enabling the method to improve the frequency response by VSWTs. In addition, the method employs FLC for pitch angle frequency control, optimizing reserve power for frequency regulation under varying wind speed levels. The innovative aspect of this study lies in the simultaneous application of FLC to pitch angle frequency control and droop/inertia control, leading to the enhanced frequency regulation capability of VSWTs and smoother operation across a range of wind speeds. Compared with traditional methods, the proposed approach provides a comprehensive and effective solution to the challenges associated with frequency regulation in VSWTs. Through simulations across different wind speed scenarios, the proposed control method demonstrated the best performance among various mature methods, highlighting the efficacy of the proposed method on the frequency regulation of VSWTs under different wind speeds. This study’s findings highlight the potential of the proposed FLC-based method to optimize frequency regulation and contribute to more reliable and efficient wind energy systems.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 01-06
Overview of Frequency Control Techniques for DFIG- Based Variable Speed Wind Turbines
In power systems, new converter-based power sources such as wind and solar farms must offer frequency control to prevent severe stability issues. The Variable Speed Wind Turbines (VSWTs), particularly Doubly Feed Induction Generator based VSWTs (DFIG-VSWTs), have become popular due to environmental concerns. By utilizing the control loops integrated in the Rotor-side converter, the DFIG-VSWTs can generate extra power from Stored Kinetic Energy (SKE) for frequency response. This paper provides a comprehensive review of the current literature on up-to-now frequency control techniques and issues of DFIG-VSWTs in interconnected power systems.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 01-06
Overview of Frequency Control Techniques for DFIG- Based Variable Speed Wind Turbines
In power systems, new converter-based power sources such as wind and solar farms must offer frequency control to prevent severe stability issues. The Variable Speed Wind Turbines (VSWTs), particularly Doubly Feed Induction Generator based VSWTs (DFIG-VSWTs), have become popular due to environmental concerns. By utilizing the control loops integrated in the Rotor-side converter, the DFIG-VSWTs can generate extra power from Stored Kinetic Energy (SKE) for frequency response. This paper provides a comprehensive review of the current literature on up-to-now frequency control techniques and issues of DFIG-VSWTs in interconnected power systems.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 256-259
Review of Power System Reliability Indices for Renewable Energy Environments
Evaluation of power system reliability is significant for power system planning and operation, especially for a power system that include many renewable power resources. Appropriate methods to estimate the reliability of generation, transmission or distribution systems can help investigate the performance of smart grid developments. Several international standards such as IEEE 1366 or IEEE 762 have been released to recommend system operators or generator owners to follow the rules. In addition, North American Electric Reliability Corporation (NERC) also defined new reliability indices, such as adequate level of reliability (ALR) metrics and others. These new reliability indices consider power system resilience. This paper will summarize the existing reliability indices for power system operation, and investigate possible resilience indices for considering severity risk. Additionally, this paper provides a future trend for resilience indices.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 256-259
Review of Power System Reliability Indices for Renewable Energy Environments
Evaluation of power system reliability is significant for power system planning and operation, especially for a power system that include many renewable power resources. Appropriate methods to estimate the reliability of generation, transmission or distribution systems can help investigate the performance of smart grid developments. Several international standards such as IEEE 1366 or IEEE 762 have been released to recommend system operators or generator owners to follow the rules. In addition, North American Electric Reliability Corporation (NERC) also defined new reliability indices, such as adequate level of reliability (ALR) metrics and others. These new reliability indices consider power system resilience. This paper will summarize the existing reliability indices for power system operation, and investigate possible resilience indices for considering severity risk. Additionally, this paper provides a future trend for resilience indices.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 264-267
Overview of Coordinated Frequency Control Technologies for Wind Turbines, HVDC and Energy Storage Systems
Modern grids contain new components, such as renewable power resources, HVDC transmissions, energy storage systems and others. These new components will affect the frequency-response characteristics in power systems. That is, some power electronics-based elements with according control schemes will replace a part of traditional thermal or hydro generators with governor droop control. Thus, novel frequency control technologies for energy storages, HVDC or energy storage systems should be studied. This paper summarized frequency control technologies for the abovementioned components, and discussed about the hybrid energy systems with control schemes. Additionally, some significant trends, including the optimal design of capacity size, adaptive droop or inertia gains of controllers, detailed models for small-signal analyses or grid forming controls, and simplified frequency-response models, were also investigated in this paper.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 264-267
Overview of Coordinated Frequency Control Technologies for Wind Turbines, HVDC and Energy Storage Systems
Modern grids contain new components, such as renewable power resources, HVDC transmissions, energy storage systems and others. These new components will affect the frequency-response characteristics in power systems. That is, some power electronics-based elements with according control schemes will replace a part of traditional thermal or hydro generators with governor droop control. Thus, novel frequency control technologies for energy storages, HVDC or energy storage systems should be studied. This paper summarized frequency control technologies for the abovementioned components, and discussed about the hybrid energy systems with control schemes. Additionally, some significant trends, including the optimal design of capacity size, adaptive droop or inertia gains of controllers, detailed models for small-signal analyses or grid forming controls, and simplified frequency-response models, were also investigated in this paper.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 252-255
Overview of Up-to-Date Frequency Control Technologies for DFIG- and PMSG-based Wind Turbines
A power system includes many system components that would affect dynamic frequency during a system contingency. Many traditional synchronous generators will be replaced by converter-based power sources, such as wind turbines. They would cause severe frequency stability problems if these new components do not provide any frequency control. That is, frequency stability will become one of the important issues in modern power grids. Thus, this paper surveyed various frequency control schemes for different types of wind turbines, and the requirements of frequency response services in electric markets.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 252-255
Overview of Up-to-Date Frequency Control Technologies for DFIG- and PMSG-based Wind Turbines
A power system includes many system components that would affect dynamic frequency during a system contingency. Many traditional synchronous generators will be replaced by converter-based power sources, such as wind turbines. They would cause severe frequency stability problems if these new components do not provide any frequency control. That is, frequency stability will become one of the important issues in modern power grids. Thus, this paper surveyed various frequency control schemes for different types of wind turbines, and the requirements of frequency response services in electric markets.
- Open Access
- 1 August 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (4) , 4253-4263
A hybrid approach of artificial neural network-particle swarm optimization algorithm for optimal load shedding strategy
This paper proposes an under-frequency load shedding (UFLS) method by using the optimization technique of artificial neural network (ANN) combined with particle swarm optimization (PSO) algorithm to determine the minimum load shedding capacity. The suggested technique using a hybrid algorithm ANN-PSO focuses on 2 main goals: determine whether process shedding plan or not and the distribution of the minimum of shedding power on each demand load bus in order to restore system’s frequency back to acceptable values. In the hybrid algorithm ANN-PSO, the PSO algorithm takes responsible for searching the optimal weights in the neural network structure, which can help to optimize the network training in terms of training speed and accuracy. The distribution of shedding power at each node considering the primary control and secondary control of the generators’ unit and the phase electrical distance between the outage generators and load nodes. The effectiveness of the proposed method is experimented with multiple generators outage cases at various load levels in the IEEE-37 Bus scheme where load shedding cases are considered compared with other traditional technique.
- 1 August 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (4) , 4253-4263
Open AccessA hybrid approach of artificial neural network-particle swarm optimization algorithm for optimal load shedding strategy
This paper proposes an under-frequency load shedding (UFLS) method by using the optimization technique of artificial neural network (ANN) combined with particle swarm optimization (PSO) algorithm to determine the minimum load shedding capacity. The suggested technique using a hybrid algorithm ANN-PSO focuses on 2 main goals: determine whether process shedding plan or not and the distribution of the minimum of shedding power on each demand load bus in order to restore system’s frequency back to acceptable values. In the hybrid algorithm ANN-PSO, the PSO algorithm takes responsible for searching the optimal weights in the neural network structure, which can help to optimize the network training in terms of training speed and accuracy. The distribution of shedding power at each node considering the primary control and secondary control of the generators’ unit and the phase electrical distance between the outage generators and load nodes. The effectiveness of the proposed method is experimented with multiple generators outage cases at various load levels in the IEEE-37 Bus scheme where load shedding cases are considered compared with other traditional technique.
- 31 August 2021
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (8) , 5276-5288
Application of AHP Algorithm to Coordinate Multiple Load Shedding Factors in the Microgrid
The rapidly drop of frequency in the microgrid (MG) system when it operates under island operation has caused frequency stability problems. In case, generators and renewable energy sources cannot supply enough power to restore the frequency, the load shedding will be proceeded. This paper proposes the load shedding method based on the coordinate multiple load shedding factors when the MG system operates in island mode. This proposed method carries out an approach through two main steps. Firstly, the optimal amount of load shedding power considering renewable energy sources and the ability to adjust the primary and secondary frequencies of the generator is calculated to restore the frequency to the allowed range. Next, distributing the optimal load shedding power for each bus is based on the combination of different criteria to meet the economic and technical goals. On the technical side, this paper also considers two criteria about the voltage distance, and the voltage sensitivity index. These two criteria contribute to reducing voltage drop and improving voltage stability when the microgrid operates in island mode. From the economic perspective, it considers the load importance factor, thereby minimizing the economic losses caused by load shedding. The AHP algorithm is applied in this paper to determine the importance of loads and the importance of the different criteria when they are combined. The effectiveness of the proposed method is demonstrated through simulation of IEEE 16-bus microgrid with 6-source.
- 31 August 2021
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (8) , 5276-5288
Application of AHP Algorithm to Coordinate Multiple Load Shedding Factors in the Microgrid
The rapidly drop of frequency in the microgrid (MG) system when it operates under island operation has caused frequency stability problems. In case, generators and renewable energy sources cannot supply enough power to restore the frequency, the load shedding will be proceeded. This paper proposes the load shedding method based on the coordinate multiple load shedding factors when the MG system operates in island mode. This proposed method carries out an approach through two main steps. Firstly, the optimal amount of load shedding power considering renewable energy sources and the ability to adjust the primary and secondary frequencies of the generator is calculated to restore the frequency to the allowed range. Next, distributing the optimal load shedding power for each bus is based on the combination of different criteria to meet the economic and technical goals. On the technical side, this paper also considers two criteria about the voltage distance, and the voltage sensitivity index. These two criteria contribute to reducing voltage drop and improving voltage stability when the microgrid operates in island mode. From the economic perspective, it considers the load importance factor, thereby minimizing the economic losses caused by load shedding. The AHP algorithm is applied in this paper to determine the importance of loads and the importance of the different criteria when they are combined. The effectiveness of the proposed method is demonstrated through simulation of IEEE 16-bus microgrid with 6-source.
- Open Access
- 6 February 2021
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 11 (1) , 6680-6686
Load Shedding in Microgrids with Consideration of Voltage Quality Improvement
Microgrids have become more and more popular their usefulness as a renewable energy resource has been recognized. The core ability and promise of microgrids is addressing the environmental concerns due to climate change that have been growing during recent years. The innovation of microgrids is that they are designed to operate either in island mode or interconnected with the main grid system. However, when the microgrid operates in islanded mode, faults may occur which can cause system collapse or even blackout. Load curtailment schemes can be utilized to decrease the quantity of associated load to a level that can be securely supported by accessible generation in isolated mode. The main goal of this research is to evaluate the optimal amount of shedding power considering sustainable power sources, with the help of primary and secondary adjustments of the generator to restore the frequency to the allowed range. Particle Swarm Optimization algorithm is applied in this paper to determine the distributed shedding power on each demand load bus which can improve the voltage quality of the isolated microgrid system. The effectiveness of the proposed method is demonstrated through the simulation of IEEE 16- bus microgrid.
- 6 February 2021
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 11 (1) , 6680-6686
Open AccessLoad Shedding in Microgrids with Consideration of Voltage Quality Improvement
Microgrids have become more and more popular their usefulness as a renewable energy resource has been recognized. The core ability and promise of microgrids is addressing the environmental concerns due to climate change that have been growing during recent years. The innovation of microgrids is that they are designed to operate either in island mode or interconnected with the main grid system. However, when the microgrid operates in islanded mode, faults may occur which can cause system collapse or even blackout. Load curtailment schemes can be utilized to decrease the quantity of associated load to a level that can be securely supported by accessible generation in isolated mode. The main goal of this research is to evaluate the optimal amount of shedding power considering sustainable power sources, with the help of primary and secondary adjustments of the generator to restore the frequency to the allowed range. Particle Swarm Optimization algorithm is applied in this paper to determine the distributed shedding power on each demand load bus which can improve the voltage quality of the isolated microgrid system. The effectiveness of the proposed method is demonstrated through the simulation of IEEE 16- bus microgrid.