Matt Waks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Matt Waks has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Gregor Adriany
Center for Magnetic Resonance Research (CMRR) University of Minnesota Minneapolis Minnesota USA
15 shared publications - Russell Luke Lagore
Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, MN 55455
13 shared publications - Kamil Ugurbil
Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, MN, USA
12 shared publications - Edward J. Auerbach
Center for Magnetic Resonance Research (CMRR) University of Minnesota Minneapolis Minnesota USA
11 shared publications - Alireza Sadeghi-Tarakameh
Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, MN 55455
10 shared publications - Steen Moeller
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, USA
8 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 441-453
A Fast B1+‐Driven RF Co‐Simulation Optimization Method for RF Coil Arrays
Purpose: To generate accurate EM simulation models of RF coil arrays, improve coil safety validation procedures, and improve RF power management without sacrificing patient safety. Methods: A fast, customized RF co‐simulation formulation was developed for pTx RF coils, enabling the use of experimentally measured maps to optimize the values of lumped elements, phase shifters, and attenuators in the EM simulation model, and demonstrate in a phantom. The proposed method was tested on an 8‐channel pTx knee coil at 7T and a 16‐channel pTx head coil at 10.5T. An RF co‐simulation optimization method that relies solely on matching the simulated and experimental ‐matrices was also implemented as a baseline. 50,000 random RF shims were used to evaluate the error for both co‐simulation optimization methods. Results: The proposed ‐driven co‐simulation optimization method generated accurate maps when compared to experimentally measured maps. The proposed method reduced the average NRMSE of the EM modeling against the measurements from 48.0% to 30.8% for the 7T 8‐channel coil, and from 91.1% to 50.9% for the 10.5T 16‐channel coil when compared to conventional methods using 50,000 random RF shims. Conclusion: The developed ‐driven RF co‐simulation optimization method in this work can be used to generate a more accurate EM simulation model of custom‐built arrays and potentially reduce the need for large safety margins, with improved RF power management.
- 29 September 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 441-453
Open AccessA Fast B1+‐Driven RF Co‐Simulation Optimization Method for RF Coil Arrays
Purpose: To generate accurate EM simulation models of RF coil arrays, improve coil safety validation procedures, and improve RF power management without sacrificing patient safety. Methods: A fast, customized RF co‐simulation formulation was developed for pTx RF coils, enabling the use of experimentally measured maps to optimize the values of lumped elements, phase shifters, and attenuators in the EM simulation model, and demonstrate in a phantom. The proposed method was tested on an 8‐channel pTx knee coil at 7T and a 16‐channel pTx head coil at 10.5T. An RF co‐simulation optimization method that relies solely on matching the simulated and experimental ‐matrices was also implemented as a baseline. 50,000 random RF shims were used to evaluate the error for both co‐simulation optimization methods. Results: The proposed ‐driven co‐simulation optimization method generated accurate maps when compared to experimentally measured maps. The proposed method reduced the average NRMSE of the EM modeling against the measurements from 48.0% to 30.8% for the 7T 8‐channel coil, and from 91.1% to 50.9% for the 10.5T 16‐channel coil when compared to conventional methods using 50,000 random RF shims. Conclusion: The developed ‐driven RF co‐simulation optimization method in this work can be used to generate a more accurate EM simulation model of custom‐built arrays and potentially reduce the need for large safety margins, with improved RF power management.
- Open Access
SNR Enhancement Considerations for Loop Receive Coils at Ultra-High Fields
Purpose: To quantify parasitic losses in ultra-high field (UHF) magnetic resonance imaging (MRI) receive coils and determine how they contribute to the mismatch between numerically predicted and experimentally realized signal-to-noise ratio (SNR), with the goal of guiding receive-array designs toward ultimate intrinsic SNR (uiSNR). Methods: SNR was measured across multiple field strengths (3T, 7T, 10.5T) using commercial and custom-built arrays. To quantify parasitic losses, unloaded-to-loaded quality factor ratio (Q R ) measurements were performed on representative loop resonators and practical RF coils. Measured losses were combined with single-loop electromagnetic simulations to separate conductor, radiation, and component losses. These bench-derived loss estimates were then incorporated into full-array electromagnetic simulations of a 128-channel receive array to evaluate their impact on predicted intrinsic SNR. Results: Measurements across field strengths supported the expected supralinear increase of SNR with B 0 . Q R analysis showed that, at UHF, radiation loss must be excluded from unloaded-Q measurements to avoid overestimating electronic-noise penalties, and that multiple seemingly modest parasitic losses collectively impose substantial SNR degradation. In the 128-channel array, simulations including only conductor and radiation losses predicted 93% of central uiSNR, whereas inclusion of the full measured parasitic-loss budget reduced predicted performance to 78%, in close agreement with the experimentally measured 77%. Conclusions: The gap between predicted and realized SNR performance of high-channel-count 10.5T loop arrays can be largely explained by parasitic losses that are not captured in conventional simulations. A bench-measurement-informed simulation framework enables more realistic prediction of coil performance and provides practical guidance for optimizing future UHF receive arrays.
Open AccessSNR Enhancement Considerations for Loop Receive Coils at Ultra-High Fields
Purpose: To quantify parasitic losses in ultra-high field (UHF) magnetic resonance imaging (MRI) receive coils and determine how they contribute to the mismatch between numerically predicted and experimentally realized signal-to-noise ratio (SNR), with the goal of guiding receive-array designs toward ultimate intrinsic SNR (uiSNR). Methods: SNR was measured across multiple field strengths (3T, 7T, 10.5T) using commercial and custom-built arrays. To quantify parasitic losses, unloaded-to-loaded quality factor ratio (Q R ) measurements were performed on representative loop resonators and practical RF coils. Measured losses were combined with single-loop electromagnetic simulations to separate conductor, radiation, and component losses. These bench-derived loss estimates were then incorporated into full-array electromagnetic simulations of a 128-channel receive array to evaluate their impact on predicted intrinsic SNR. Results: Measurements across field strengths supported the expected supralinear increase of SNR with B 0 . Q R analysis showed that, at UHF, radiation loss must be excluded from unloaded-Q measurements to avoid overestimating electronic-noise penalties, and that multiple seemingly modest parasitic losses collectively impose substantial SNR degradation. In the 128-channel array, simulations including only conductor and radiation losses predicted 93% of central uiSNR, whereas inclusion of the full measured parasitic-loss budget reduced predicted performance to 78%, in close agreement with the experimentally measured 77%. Conclusions: The gap between predicted and realized SNR performance of high-channel-count 10.5T loop arrays can be largely explained by parasitic losses that are not captured in conventional simulations. A bench-measurement-informed simulation framework enables more realistic prediction of coil performance and provides practical guidance for optimizing future UHF receive arrays.
- Open Access
An 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization
Purpose: High-density RF receive arrays are required to realize the inherently available SNR and parallel imaging advantages at ultrahigh field strengths, which are essential for high-resolution functional and anatomical brain MRI. This study aims to systematically assess the impacts of often-overlooked parasitic losses associated with various RF coil components, as these losses can degrade the realized SNR and cause significant deviation from the ultimate intrinsic SNR (uiSNR; the theoretical upper bound of available SNR). In addition, we seek to detail engineering solutions to each of these loss mechanisms in pursuit of achieving a higher fraction of the uiSNR limit. Methods: A 16-channel loop-folded dipole transceiver array was developed for 10.5T human head applications and paired with a fully-updated 64-channel receive-only loop array. The optimization of the receive array considered several factors, including (but not limited to) coil dimensions to accommodate a larger population, the size and number of loops to enhance SNR and parallel imaging performance, and circuit design strategies to minimize parasitic losses. The SNR and parallel imaging performance of the receive array were quantitatively assessed by comparison with the uiSNR, as well as existing high-channel-count receive arrays at 7T and 10.5T. Finally, the complete 16-channel transmit, 80-channel receive coil array was safety validated for human use and employed for high-resolution functional and anatomical MRI at 10.5T. Results: Initial results show that the 80-channel array, featuring larger loops in an overlapped layout with optimized circuitry, significantly improves the SNR and approaches the uiSNR limit in a large fraction of the head, while maintaining or enhancing the parallel imaging performance compared to previously used non-overlap layout. Conclusion: This study suggests that, although the traditionally used high-channel-count loop receive array technology can approach the uiSNR limit in the >10T regime, meticulous design optimization—including systematic assessment and minimization of parasitic losses—has become increasingly critical for achieving this goal in this new field-strength territory.
Open AccessAn 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization
Purpose: High-density RF receive arrays are required to realize the inherently available SNR and parallel imaging advantages at ultrahigh field strengths, which are essential for high-resolution functional and anatomical brain MRI. This study aims to systematically assess the impacts of often-overlooked parasitic losses associated with various RF coil components, as these losses can degrade the realized SNR and cause significant deviation from the ultimate intrinsic SNR (uiSNR; the theoretical upper bound of available SNR). In addition, we seek to detail engineering solutions to each of these loss mechanisms in pursuit of achieving a higher fraction of the uiSNR limit. Methods: A 16-channel loop-folded dipole transceiver array was developed for 10.5T human head applications and paired with a fully-updated 64-channel receive-only loop array. The optimization of the receive array considered several factors, including (but not limited to) coil dimensions to accommodate a larger population, the size and number of loops to enhance SNR and parallel imaging performance, and circuit design strategies to minimize parasitic losses. The SNR and parallel imaging performance of the receive array were quantitatively assessed by comparison with the uiSNR, as well as existing high-channel-count receive arrays at 7T and 10.5T. Finally, the complete 16-channel transmit, 80-channel receive coil array was safety validated for human use and employed for high-resolution functional and anatomical MRI at 10.5T. Results: Initial results show that the 80-channel array, featuring larger loops in an overlapped layout with optimized circuitry, significantly improves the SNR and approaches the uiSNR limit in a large fraction of the head, while maintaining or enhancing the parallel imaging performance compared to previously used non-overlap layout. Conclusion: This study suggests that, although the traditionally used high-channel-count loop receive array technology can approach the uiSNR limit in the >10T regime, meticulous design optimization—including systematic assessment and minimization of parasitic losses—has become increasingly critical for achieving this goal in this new field-strength territory.
- Open Access
- 7 April 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 817-825
Mesoscale Whole‐Brain T 2 *‐Weighted and Associated Quantitative MRI in Humans at 10.5 T
Purpose: To demonstrate mesoscale whole‐brain T 2 *‐weighted ( T 2 *w) MRI at 10.5 T, quantify R 2 * relaxation rate and magnetic susceptibility ( χ ), and evaluate T 2 *w contrast at such high field strength. Methods: Multi‐echo GRE (ME‐GRE) data were collected in healthy adults at 0.5 mm isotropic resolution at 10.5 T. Whole‐brain images were reconstructed with navigator‐guided joint motion and field correction and were used for quantitative R 2 * and χ mapping. Regional R 2 * and χ values and R 2 * contrast were analyzed in volumetric regions of interest (ROIs) and intra‐cortical surface‐based ROIs. For comparison, ME‐GRE data from the same subjects were acquired using a similar protocol at 7 T. Results: High‐quality whole‐brain T 2 *w images were obtained, enabling R 2 * and χ mapping with delineation of fine‐scale brain structures. Regional R 2 * analysis revealed a linear relationship between 10.5 T and 7 T R 2 * values with a slope of 1.52, in agreement with previously reported linear field dependency of R 2 *. Estimated χ values were field‐independent in most brain regions under consideration except for the basal ganglia where χ was observed to be lower at 10.5 T than at 7 T. The normalized R 2 * contrast that is, the R 2 * difference normalized by the mean R 2 *, increased by about 3% between brain regions and 12% between cortical depths from 7 to 10.5 T. Conclusion: It is feasible to achieve high‐quality mesoscale whole‐brain T 2 *w MRI at 10.5 T and associated quantitative R 2 * and χ mapping. Our results may aid future optimization of anatomic T 2 *w brain MRI at ultrahigh field beyond 7 T.
- 7 April 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 817-825
Open AccessMesoscale Whole‐Brain T 2 *‐Weighted and Associated Quantitative MRI in Humans at 10.5 T
Purpose: To demonstrate mesoscale whole‐brain T 2 *‐weighted ( T 2 *w) MRI at 10.5 T, quantify R 2 * relaxation rate and magnetic susceptibility ( χ ), and evaluate T 2 *w contrast at such high field strength. Methods: Multi‐echo GRE (ME‐GRE) data were collected in healthy adults at 0.5 mm isotropic resolution at 10.5 T. Whole‐brain images were reconstructed with navigator‐guided joint motion and field correction and were used for quantitative R 2 * and χ mapping. Regional R 2 * and χ values and R 2 * contrast were analyzed in volumetric regions of interest (ROIs) and intra‐cortical surface‐based ROIs. For comparison, ME‐GRE data from the same subjects were acquired using a similar protocol at 7 T. Results: High‐quality whole‐brain T 2 *w images were obtained, enabling R 2 * and χ mapping with delineation of fine‐scale brain structures. Regional R 2 * analysis revealed a linear relationship between 10.5 T and 7 T R 2 * values with a slope of 1.52, in agreement with previously reported linear field dependency of R 2 *. Estimated χ values were field‐independent in most brain regions under consideration except for the basal ganglia where χ was observed to be lower at 10.5 T than at 7 T. The normalized R 2 * contrast that is, the R 2 * difference normalized by the mean R 2 *, increased by about 3% between brain regions and 12% between cortical depths from 7 to 10.5 T. Conclusion: It is feasible to achieve high‐quality mesoscale whole‐brain T 2 *w MRI at 10.5 T and associated quantitative R 2 * and χ mapping. Our results may aid future optimization of anatomic T 2 *w brain MRI at ultrahigh field beyond 7 T.
- Open Access
- 31 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 469-484
A Numerical Alternative to MR Thermometry for Safety Validation of Multi‐Channel RF Transmit Coils
Purpose: This study proposes a numerical technique to estimate peak local specific absorption rate (SAR) uncertainty of multi‐channel RF coils during the process of safety validation as an alternative to experimental temperature and electric‐field measurements, and demonstrates its use to enable human studies at 10.5 T. Methods: To ensure patient safety, SAR limits established under international guidelines must not be exceeded. Predicting SAR on state‐of‐the‐art parallel transmit systems relies on electromagnetic simulations, which require extensive experimental validation. Despite a well‐established validation workflow, SAR prediction errors are unavoidable and must be quantified as a safety margin. While MRT tests are commonly used for this purpose, their technical challenges necessitate an alternative. The proposed technique propagates the error between experimentally and numerically acquired distributions to the uncertainty in simulated peak local SAR using Monte‐Carlo simulations without the need for MRT. This method was validated using a 16‐channel transceiver 10.5 T torso coil, as well as an 8‐channel 10.5 T head coil. Results: The proposed numerical technique proved more conservative than existing MRT‐based SAR error quantification methods across all tested scenarios. Its application to validate three state‐of‐the‐art head coils (16Tx/32Rx, 16Tx/80Rx, and 16Tx/128Rx) led to regulatory approval for human head imaging and high‐quality diffusion and functional MRI results at 10.5 T. Conclusion: The proposed technique requires only the experimental acquisition of maps for comparison with simulations, enabling the estimation of SAR prediction uncertainty. This technique was applied to three 16‐channel transmit arrays, each used in conjunction with high‐channel‐count receive arrays for in vivo imaging.
- 31 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 469-484
Open AccessA Numerical Alternative to MR Thermometry for Safety Validation of Multi‐Channel RF Transmit Coils
Purpose: This study proposes a numerical technique to estimate peak local specific absorption rate (SAR) uncertainty of multi‐channel RF coils during the process of safety validation as an alternative to experimental temperature and electric‐field measurements, and demonstrates its use to enable human studies at 10.5 T. Methods: To ensure patient safety, SAR limits established under international guidelines must not be exceeded. Predicting SAR on state‐of‐the‐art parallel transmit systems relies on electromagnetic simulations, which require extensive experimental validation. Despite a well‐established validation workflow, SAR prediction errors are unavoidable and must be quantified as a safety margin. While MRT tests are commonly used for this purpose, their technical challenges necessitate an alternative. The proposed technique propagates the error between experimentally and numerically acquired distributions to the uncertainty in simulated peak local SAR using Monte‐Carlo simulations without the need for MRT. This method was validated using a 16‐channel transceiver 10.5 T torso coil, as well as an 8‐channel 10.5 T head coil. Results: The proposed numerical technique proved more conservative than existing MRT‐based SAR error quantification methods across all tested scenarios. Its application to validate three state‐of‐the‐art head coils (16Tx/32Rx, 16Tx/80Rx, and 16Tx/128Rx) led to regulatory approval for human head imaging and high‐quality diffusion and functional MRI results at 10.5 T. Conclusion: The proposed technique requires only the experimental acquisition of maps for comparison with simulations, enabling the estimation of SAR prediction uncertainty. This technique was applied to three 16‐channel transmit arrays, each used in conjunction with high‐channel‐count receive arrays for in vivo imaging.
- Open Access
10.5 Tesla High-Resolution Macaque Brain MRI for Connectivity Studies
Mapping brain connectivity in primates remains a major challenge due to difficulties in resolving microscopic white matter architecture, while maintaining whole-brain coverage. Increasing imaging spatial resolution is key for disambiguating fiber configurations within smaller anatomical volumes. Here, we present developments that allow high-resolution diffusion MRI of the macaque brain, both in vivo and ex vivo, using one of the world’s highest-field human MRI scanners operating at 10.5 Tesla. Our approach achieves data of highest reported resolutions for this field strength and scanner type, (750 μm ) 3 in vivo and (400 μm ) 3 ex vivo , with diffusion weighting up to b = 6000 s/mm 2 . We detail methodological advances in data acquisition, image reconstruction, processing and whole-brain tractography that overcome critical challenges associated with ultra-high-field imaging. This work establishes a new benchmark for high-resolution neuroimaging at 10.5T, paving the way for comparable human studies and enabling analyses of brain connectivity across species and tissue states at unprecedented detail. The dataset, along with all processing pipelines, containerised workflows, and reusable web services, is openly shared to support reproducibility and future integration with microscopy for studying white matter microstructure and connections at the mesoscale.
Open Access10.5 Tesla High-Resolution Macaque Brain MRI for Connectivity Studies
Mapping brain connectivity in primates remains a major challenge due to difficulties in resolving microscopic white matter architecture, while maintaining whole-brain coverage. Increasing imaging spatial resolution is key for disambiguating fiber configurations within smaller anatomical volumes. Here, we present developments that allow high-resolution diffusion MRI of the macaque brain, both in vivo and ex vivo, using one of the world’s highest-field human MRI scanners operating at 10.5 Tesla. Our approach achieves data of highest reported resolutions for this field strength and scanner type, (750 μm ) 3 in vivo and (400 μm ) 3 ex vivo , with diffusion weighting up to b = 6000 s/mm 2 . We detail methodological advances in data acquisition, image reconstruction, processing and whole-brain tractography that overcome critical challenges associated with ultra-high-field imaging. This work establishes a new benchmark for high-resolution neuroimaging at 10.5T, paving the way for comparable human studies and enabling analyses of brain connectivity across species and tissue states at unprecedented detail. The dataset, along with all processing pipelines, containerised workflows, and reusable web services, is openly shared to support reproducibility and future integration with microscopy for studying white matter microstructure and connections at the mesoscale.
- Open Access
Diffusion-weighted steady-state free precession imaging in the ex vivo macaque brain on a 10.5T human MRI scanner
Diffusion MRI provides a non-invasive probe of local fibre bundles and long-range anatomical connections to characterise the structural connectome. One way to achieve very high spatial resolution diffusion MRI data for connectivity investigations is to scan ex-vivo brains over many hours or days, ideally at ultra-high field strength to boost signal levels. However, conventional diffusion MRI acquisition techniques do not generally deliver good data quality for the challenging conditions of ex-vivo tissue, characterised by reduced diffusivities and relaxation times when compared to in vivo. In this work, we investigate the potential of the diffusion-weighted steady-state free precession (DW-SSFP) sequence for ex vivo diffusion imaging of the macaque brain using a 10.5 T human MRI scanner with a conventional (G_max=70 mT/m) gradient set. SNR-efficiency optimisations incorporating experimental relaxation times demonstrate that the DW-SSFP sequence is predicted to achieve improved or similar SNR efficiency compared to a diffusion-weighted spin- and stimulated-echo sequence. Importantly, DW-SSFP can achieve this with the additional benefit of negligible geometric distortions, unlike conventional diffusion MRI using an echo-planar imaging readout. Using optimised DW-SSFP sequence parameters, we propose a protocol at 0.4 mm isotropic resolution using a two-shell multi-orientation protocol (effective b-values of 3200 s/mm^2 and 5600 s/mm^2). We fit the data using Tensor, Ball and 3-Sticks and Constrained Spherical Deconvolution signal representations. The results demonstrate high-quality diffusivity estimates across the entire brain with the ability to resolve multiple fibre populations in challenging crossing-fibre regions. The data will be made fully open source and multimodal as part of the Center for Mesoscale Connectomics, providing a resource for future connectivity investigations.
Open AccessDiffusion-weighted steady-state free precession imaging in the ex vivo macaque brain on a 10.5T human MRI scanner
Diffusion MRI provides a non-invasive probe of local fibre bundles and long-range anatomical connections to characterise the structural connectome. One way to achieve very high spatial resolution diffusion MRI data for connectivity investigations is to scan ex-vivo brains over many hours or days, ideally at ultra-high field strength to boost signal levels. However, conventional diffusion MRI acquisition techniques do not generally deliver good data quality for the challenging conditions of ex-vivo tissue, characterised by reduced diffusivities and relaxation times when compared to in vivo. In this work, we investigate the potential of the diffusion-weighted steady-state free precession (DW-SSFP) sequence for ex vivo diffusion imaging of the macaque brain using a 10.5 T human MRI scanner with a conventional (G_max=70 mT/m) gradient set. SNR-efficiency optimisations incorporating experimental relaxation times demonstrate that the DW-SSFP sequence is predicted to achieve improved or similar SNR efficiency compared to a diffusion-weighted spin- and stimulated-echo sequence. Importantly, DW-SSFP can achieve this with the additional benefit of negligible geometric distortions, unlike conventional diffusion MRI using an echo-planar imaging readout. Using optimised DW-SSFP sequence parameters, we propose a protocol at 0.4 mm isotropic resolution using a two-shell multi-orientation protocol (effective b-values of 3200 s/mm^2 and 5600 s/mm^2). We fit the data using Tensor, Ball and 3-Sticks and Constrained Spherical Deconvolution signal representations. The results demonstrate high-quality diffusivity estimates across the entire brain with the ability to resolve multiple fibre populations in challenging crossing-fibre regions. The data will be made fully open source and multimodal as part of the Center for Mesoscale Connectomics, providing a resource for future connectivity investigations.
- Open Access
An RF coil array system for in vivo & ex vivo non-human primate brain studies at 10.5 Tesla
Purpose: We aimed to develop an innovative RF coil toolset for high resolution in vivo and ex vivo non-human primate neuroimaging applications at 10.5T MRI. The main goal was to improve our multimodal neural connectivity pipeline through the improved SNR, CNR, and spatial resolution that result from utilizing high-density RF coil arrays in combination with ultra-high field MRI. Methods: Two RF coil arrays, both comprising 8 transmit and 40 receive channels, were designed and built for in vivo and ex vivo NHP imaging at 10.5 T. Experimental data was collected on multiple in vivo and ex vivo specimens, showing the utility UHF MRI for NHP neuroscience. Results: Experimental results demonstrate uniform whole-brain coverage within both in vivo—which included the cerebellar, and spinal cord regions—and ex vivo specimens. High spatial resolutions (in vivo: 0.1×0.1×0.5 mm, ex vivo: 120 micron isotropic ) were achieved, revealing detailed anatomical structures throughout. High temporal stability allowed for EPI and dMRI applications. Conclusion: An RF coil toolset comprising two 8ch transmit/40ch receive arrays was successfully designed for both in vivo and ex vivo NHP brain applications at 10.5 T. Both high-density RF coil arrays coupled with the SNR and CNR benefits available at UHF supported unmatched anatomical, functional, and diffusion applications at some of the highest spatial resolutions to date. Additionally, the combined capability of both in vivo and ex vivo MRI with the same brain specimen allows for tighter control for experimental-paradigm multistage studies examining translation between in vivo and ex vivo methodologies.
Open AccessAn RF coil array system for in vivo & ex vivo non-human primate brain studies at 10.5 Tesla
Purpose: We aimed to develop an innovative RF coil toolset for high resolution in vivo and ex vivo non-human primate neuroimaging applications at 10.5T MRI. The main goal was to improve our multimodal neural connectivity pipeline through the improved SNR, CNR, and spatial resolution that result from utilizing high-density RF coil arrays in combination with ultra-high field MRI. Methods: Two RF coil arrays, both comprising 8 transmit and 40 receive channels, were designed and built for in vivo and ex vivo NHP imaging at 10.5 T. Experimental data was collected on multiple in vivo and ex vivo specimens, showing the utility UHF MRI for NHP neuroscience. Results: Experimental results demonstrate uniform whole-brain coverage within both in vivo—which included the cerebellar, and spinal cord regions—and ex vivo specimens. High spatial resolutions (in vivo: 0.1×0.1×0.5 mm, ex vivo: 120 micron isotropic ) were achieved, revealing detailed anatomical structures throughout. High temporal stability allowed for EPI and dMRI applications. Conclusion: An RF coil toolset comprising two 8ch transmit/40ch receive arrays was successfully designed for both in vivo and ex vivo NHP brain applications at 10.5 T. Both high-density RF coil arrays coupled with the SNR and CNR benefits available at UHF supported unmatched anatomical, functional, and diffusion applications at some of the highest spatial resolutions to date. Additionally, the combined capability of both in vivo and ex vivo MRI with the same brain specimen allows for tighter control for experimental-paradigm multistage studies examining translation between in vivo and ex vivo methodologies.
- Open Access
- 17 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 1068-1088
Advancing whole‐brain BOLD functional MRI in humans at 10.5 T with motion‐robust 3D echo‐planar imaging , parallel transmission, and high‐density radiofrequency receive coils
Purpose: To demonstrate the feasibility and performance of whole‐brain blood oxygen level–dependent functional MRI (fMRI) in humans at 10.5 T by combining motion‐robust three‐dimensional gradient‐echo echo‐planar imaging, parallel transmission, and high‐density radiofrequency (RF) receive coils. Methods: Resting‐state fMRI time series were collected in healthy adults at 1.58 mm and approximately 2‐s spatiotemporal resolution using a custom‐built 16‐channel transmit/80‐channel receive RF array. Individualized parallel‐transmission, spatial‐spectral RF pulses were designed to achieve uniform water‐selective excitation across the entire brain without the need for additional fat saturation. Images were reconstructed with navigator‐guided joint motion and field correction. Reconstructed images were preprocessed using fMRIPrep and postprocessed using XCP‐D pipelines. Relevant resting‐state fMRI metrics were evaluated including temporal SNR (tSNR), amplitude of low‐frequency fluctuation, and regional homogeneity. The results were compared with those obtained using uncorrected reconstruction (i.e., using same raw data but without motion or field correction). Results: Our motion‐corrected reconstruction largely improved image quality for fMRI time series, reducing motion confounds when compared with uncorrected reconstruction. The reduction in motion confounds translated into an improvement in tSNR, with tSNR averaged across all volunteers being increased by about 11%. Our motion‐corrected reconstruction also improved both amplitude of low‐frequency fluctuation and regional homogeneity in most cortical surfaces and subcortical regions. Conclusion: It is feasible to perform quality three‐dimensional whole‐brain blood oxygen level–dependent fMRI in humans at 10.5 T using a new comprehensive motion‐robust imaging method. This work paves the way for promising future applications at 10.5 T aimed at studying brain function and networks with high spatiotemporal resolution.
- 17 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 1068-1088
Open AccessAdvancing whole‐brain BOLD functional MRI in humans at 10.5 T with motion‐robust 3D echo‐planar imaging , parallel transmission, and high‐density radiofrequency receive coils
Purpose: To demonstrate the feasibility and performance of whole‐brain blood oxygen level–dependent functional MRI (fMRI) in humans at 10.5 T by combining motion‐robust three‐dimensional gradient‐echo echo‐planar imaging, parallel transmission, and high‐density radiofrequency (RF) receive coils. Methods: Resting‐state fMRI time series were collected in healthy adults at 1.58 mm and approximately 2‐s spatiotemporal resolution using a custom‐built 16‐channel transmit/80‐channel receive RF array. Individualized parallel‐transmission, spatial‐spectral RF pulses were designed to achieve uniform water‐selective excitation across the entire brain without the need for additional fat saturation. Images were reconstructed with navigator‐guided joint motion and field correction. Reconstructed images were preprocessed using fMRIPrep and postprocessed using XCP‐D pipelines. Relevant resting‐state fMRI metrics were evaluated including temporal SNR (tSNR), amplitude of low‐frequency fluctuation, and regional homogeneity. The results were compared with those obtained using uncorrected reconstruction (i.e., using same raw data but without motion or field correction). Results: Our motion‐corrected reconstruction largely improved image quality for fMRI time series, reducing motion confounds when compared with uncorrected reconstruction. The reduction in motion confounds translated into an improvement in tSNR, with tSNR averaged across all volunteers being increased by about 11%. Our motion‐corrected reconstruction also improved both amplitude of low‐frequency fluctuation and regional homogeneity in most cortical surfaces and subcortical regions. Conclusion: It is feasible to perform quality three‐dimensional whole‐brain blood oxygen level–dependent fMRI in humans at 10.5 T using a new comprehensive motion‐robust imaging method. This work paves the way for promising future applications at 10.5 T aimed at studying brain function and networks with high spatiotemporal resolution.
- Open Access
- 13 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2680-2698
A 128‐channel receive array with enhanced signal‐to‐noise ratio performance for 10.5T brain imaging
Purpose: To develop and characterize a 128‐channel head array for brain imaging at 10.5 T, evaluate signal‐to‐noise ratio (SNR) relative to ultimate intrinsic SNR (uiSNR) and lower field strengths, and demonstrate human brain anatomical and functional imaging with this unique magnetic field and high‐channel‐count array. Methods: The coil consists of a 16‐channel self‐decoupled loop transmit/receive (16Tx/Rx) array with a 112‐loop receive‐only (Rx) insert. Interactions between the 16Tx/Rx array and the 112Rx insert were mitigated using coaxial cable traps placed every 1/16 of a wavelength on each feed cable, locating most preamplifier boards outside the transmitter field, and miniaturizing those placed directly on individual coils. Results: The effect of the 112Rx insert on the circumscribing 16Tx/Rx array was minimized, leading to similar transmit field maps obtained experimentally with and without the 112Rx array in place and by electromagnetic simulations of the 16Tx/Rx array alone. The 128‐channel array captured 77% of uiSNR centrally. Significantly higher 1/g‐factor values across the whole brain was achieved compared with 7 T. Excellent SNR, high parallel‐imaging performance, and minimal Tx‐Rx interactions collectively facilitated acquisition of high‐quality, high‐resolution, proof‐of‐concept functional and anatomical images, including with power‐demanding sequences in the human brain. Conclusions: Counterintuitive to expectations based on magnetic fields less than or equal to 7 T, the higher channel counts provided SNR gains centrally, capturing about 80% uiSNR. The fraction of uiSNR achieved centrally in 64Rx, 80Rx, and 128Rx arrays suggested that a plateau was being reached at 80%. At this plateau, B 0 ‐dependent SNR gains for 10.5 T relative to 7 T were approximately linear to quadratic for the periphery and the center, respectively.
- 13 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2680-2698
Open AccessA 128‐channel receive array with enhanced signal‐to‐noise ratio performance for 10.5T brain imaging
Purpose: To develop and characterize a 128‐channel head array for brain imaging at 10.5 T, evaluate signal‐to‐noise ratio (SNR) relative to ultimate intrinsic SNR (uiSNR) and lower field strengths, and demonstrate human brain anatomical and functional imaging with this unique magnetic field and high‐channel‐count array. Methods: The coil consists of a 16‐channel self‐decoupled loop transmit/receive (16Tx/Rx) array with a 112‐loop receive‐only (Rx) insert. Interactions between the 16Tx/Rx array and the 112Rx insert were mitigated using coaxial cable traps placed every 1/16 of a wavelength on each feed cable, locating most preamplifier boards outside the transmitter field, and miniaturizing those placed directly on individual coils. Results: The effect of the 112Rx insert on the circumscribing 16Tx/Rx array was minimized, leading to similar transmit field maps obtained experimentally with and without the 112Rx array in place and by electromagnetic simulations of the 16Tx/Rx array alone. The 128‐channel array captured 77% of uiSNR centrally. Significantly higher 1/g‐factor values across the whole brain was achieved compared with 7 T. Excellent SNR, high parallel‐imaging performance, and minimal Tx‐Rx interactions collectively facilitated acquisition of high‐quality, high‐resolution, proof‐of‐concept functional and anatomical images, including with power‐demanding sequences in the human brain. Conclusions: Counterintuitive to expectations based on magnetic fields less than or equal to 7 T, the higher channel counts provided SNR gains centrally, capturing about 80% uiSNR. The fraction of uiSNR achieved centrally in 64Rx, 80Rx, and 128Rx arrays suggested that a plateau was being reached at 80%. At this plateau, B 0 ‐dependent SNR gains for 10.5 T relative to 7 T were approximately linear to quadratic for the periphery and the center, respectively.