KSKatherine A. Spoth

Katherine A. Spoth

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Katherine A. Spoth has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct from the seed: an atomic resolution protein structure by ab initio MicroED

    by Purna Chandra Rao Vasireddy, Timothy Low-Beer, Katherine A. Spoth, Devrim Acehan, Matthew R. Crawley, Michael W. Martynowycz

    While purifying the seed protein crambin, we find that needles of pure protein nanocrystals form spontaneously during the drying of a simple ethanolic purification drop. These needles diffract X-rays weakly but are well-suited for microcrystal electron diffraction (MicroED). Merging data from 58 such nanocrystals yields diffraction to 0.85 Å resolution and solves the structure ab initio using a five-residue helical fragment to initiate density modification. The resulting map enables automated model building and resolves individual hydrogen atoms. This work reports an atomic resolution MicroED structure of the protein crambin solved ab initio. This study establishes a publicly available benchmark showing that sub-ångström ab initio MicroED can be achieved on standard 200 kV instrumentation without energy filtering or FIB milling, when serial merging is combined with anisotropy aware truncation to address preferred orientation. For this dataset, isotropic truncation alone did not produce a fragment placement suitable for phasing in this workflow, whereas applying anisotropy correction supported an ab initio solution.


  • Top Cited Papers
    Open Access

    Dose-efficient cryo-electron microscopy for thick samples using tilt- corrected scanning transmission electron microscopy

    by Yue Yu, Katherine A. Spoth, Michael Colletta, Kayla X. Nguyen, Steven E. Zeltmann, Xiyue S. Zhang, Mohammadreza Paraan, Mykhailo Kopylov, Charlie Dubbeldam, Daniel Serwas, et al.

    Cryogenic electron microscopy is a powerful tool in structural biology. In thick specimens, challenges arise as an exponentially larger fraction of the transmitted electrons lose energy from inelastic scattering and can no longer be properly focused as a result of chromatic aberrations in the post-specimen optics. Rather than filtering out the inelastic scattering at the price of reducing potential signal, as is done in energy-filtered transmission electron microscopy, we show how a dose-efficient and unfiltered image can be rapidly obtained using tilt-corrected bright-field scanning transmission electron microscopy data collected on a pixelated detector. Enhanced contrast and a 3–5× improvement in dose efficiency are observed for two-dimensional images of intact bacterial cells and large organelles using tilt-corrected bright-field scanning transmission electron microscopy compared to energy-filtered transmission electron microscopy for thicknesses beyond 500 nm. As a proof of concept for the technique’s performance in structural determination, we present a single-particle analysis map at sub-nanometer resolution for a highly symmetric virus-like particle determined from 789 particles.


  • Open Access

    Dose-Efficient Cryo-Electron Microscopy for Thick Samples using Tilt-Corrected Scanning Transmission Electron Microscopy, Demonstrated on Cells and Single Particles

    by Yue Yu, Katherine Spoth, Michael Colletta, Kayla Nguyen, Steven Zeltmann, Xiyue Zhang, Mohammadreza Paraan, Mykailo Kopylov, Charlie Dubbeldam, Daniel Serwas, et al.

    Cryo-EM is a powerful tool in structural biology, providing insights through techniques like single-particle analysis (SPA) and cryogenic electron tomography (cryo-ET). In thick specimens, challenges arise as an exponentially larger fraction of the transmitted electrons lose energy from inelastic scattering and can no longer be properly focused as a result of chromatic aberrations in the post-specimen optics. Rather than filtering out the inelastic scattering at the price of reducing potential signal, as is done in energy-filtered transmission electron microscopy (EFTEM), we show how a dose-efficient and unfiltered image can be rapidly obtained using tilt-corrected bright-field scanning-TEM (tcBF-STEM) data collected on a pixelated detector. Enhanced contrast and a 3-5x improvement in collection efficiency are observed for 2D images of intact bacterial cells and large organelles using tcBF-STEM compared to EFTEM for thicknesses beyond 500 nm. As a proof of concept for the technique’s performance in structural determination, we present an SPA map at subnanometer resolution for a highly symmetric virus-like particle (VLP) with 789 particles. These findings suggest applications for tcBF-STEM in cryo-EM of thicker cellular volumes where current approaches struggle.


  • Open Access

    Reaching the potential of electron diffraction

    by Devrim Acehan, Katherine A. Spoth, Gabrielle R. Budziszewski, M. Elizabeth Snell, Christopher S. Campomizzi, Miranda L. Lynch, Sarah E.J. Bowman


  • Open Access

    Dose-Efficient Cryo-Electron Microscopy for Thick Samples using Tilt-Corrected Scanning Transmission Electron Microscopy, Demonstrated on Cells and Single Particles

    by Yue Yu, Katherine A. Spoth, Michael Colletta, Kayla X. Nguyen, Steven E. Zeltmann, Xiyue S. Zhang, Mohammadreza Paraan, Mykhailo Kopylov, Charlie Dubbeldam, Daniel Serwas, et al.

    Cryo-EM is a powerful tool in structural biology, providing insights through techniques like single-particle analysis (SPA) and cryogenic electron tomography (cryo-ET). In thick specimens, challenges arise as an exponentially larger fraction of the transmitted electrons lose energy from inelastic scattering and can no longer be properly focused as a result of chromatic aberrations in the post-specimen optics. Rather than filtering out the inelastic scattering at the price of reducing potential signal, as is done in energy-filtered transmission electron microscopy (EFTEM), we show how a dose-efficient and unfiltered image can be rapidly obtained using tilt-corrected bright-field scanning-TEM (tcBF-STEM) data collected on a pixelated detector. Enhanced contrast and a 3-5x improvement in collection efficiency are observed for 2D images of intact bacterial cells and large organelles using tcBF-STEM compared to EFTEM for thicknesses beyond 500 nm. As a proof of concept for the technique’s performance in structural determination, we present an SPA map at subnanometer resolution for a highly symmetric virus-like particle (VLP) with 789 particles. These findings suggest applications for tcBF-STEM in cryo-EM of thicker cellular volumes where current approaches struggle.


  • Open Access

    High-resolution single-particle cryo-EM of samples vitrified in boiling nitrogen

    by Tyler Engstrom, Jonathan A. Clinger, Katherine A. Spoth, Oliver B. Clarke, David S. Closs, Richard Jayne, Benjamin A. Apker, Robert E. Thorne

    Based on work by Dubochet and others in the 1980s and 1990s, samples for single-particle cryo-electron microscopy (cryo-EM) have been vitrified using ethane, propane or ethane/propane mixtures. These liquid cryogens have a large difference between their melting and boiling temperatures and so can absorb substantial heat without formation of an insulating vapor layer adjacent to a cooling sample. However, ethane and propane are flammable, they must be liquified in liquid nitrogen immediately before cryo-EM sample preparation, and cryocooled samples must be transferred to liquid nitrogen for storage, complicating workflows and increasing the chance of sample damage during handling. Experiments over the last 15 years have shown that cooling rates required to vitrify pure water are only ∼250 000 K s−1, at the low end of earlier estimates, and that the dominant factor that has limited cooling rates of small samples in liquid nitrogen is sample precooling in cold gas present above the liquid cryogen surface, not the Leidenfrost effect. Using an automated cryocooling instrument developed for cryocrystallography that combines high plunge speeds with efficient removal of cold gas, we show that single-particle cryo-EM samples on commercial grids can be routinely vitrified using only boiling nitrogen and obtain apoferritin datasets and refined structures with 2.65 Å resolution. The use of liquid nitrogen as the primary coolant may allow manual and automated workflows to be simplified and may reduce sample stresses that contribute to beam-induced motion.


  • Stability of niosomes with encapsulated vitamin D3 and ferrous sulfate generated using a novel supercritical carbon dioxide method

    by Michael E. Wagner, Katherine A. Spoth, Lena F. Kourkoutis, Syed S. H. Rizvi

    Niosomes were prepared using a novel supercritical carbon dioxide based method to simultaneously encapsulate ferrous sulfate and vitamin D3 as hydrophilic and hydrophobic cargo, respectively. Vesicle particle size was determined to be bimodal with peak diameters of 1.44 ± 0.16 μm and 7.21 ± 0.64 μm, with the smaller peak comprising 98.8% of the total niosomal volume. Encapsulation efficiency of ferrous sulfate was 25.1 ± 0.2% and encapsulation efficiency of vitamin D3 was 95.9 ± 1.47%. Physical stability of the produced niosomes was assessed throughout a storage period of 21 days. Niosomes showed good physical stability at 20 °C, but storage at 4 °C showed an initial burst release, indicating possible rupture of the niosomal membrane. The Korsmeyer–Peppas equation was used to model the release of ferrous sulfate over time at both storage temperatures.