Şerif Nizamoğulları
Şerif Nizamoğulları has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ersin Muhafiz
Department of Ophthalmology, Faculty of Medicine, Kafkas University, Kars, Turkey
2 shared publications - Bayram Meydan
Düzce University
1 shared publication Can Emre Erdoğan
Neurology Department, Denizli State Hospital, Denizli, Turkey
1 shared publication- Can Emre Erdoğan
Department of Neurology, Denizli State Hospital, Denizli, Turkey
1 shared publication Erdinç Bozkurt
Ophthalmology Department, Kafkas University Faculty of Medicine, Kars, Turkey
1 shared publication- Erdinç Bozkurt
University of Health Sciences, Ümraniye Training and Research Hospital, Department of Ophthalmology, İstanbul, Turkey
1 shared publication
Latest Publications
- Open Access
- 8 July 2025
- Vol. 25 (1) , 397
Pupillographic evaluation accompanying structural and functional assessment of the optic nerve in patients with Parkinson's disease.
To evaluate static and dynamic pupillary functions, contrast sensitivity, and retinal nerve fiber layer (RNFL) thickness in patients with Parkinson's disease. The study included 25 right eyes of patients with Parkinson's disease (mean age: 67.88 ± 9.40 years) and 26 right eyes of age- and sex-matched healthy controls (mean age: 64.15 ± 7.60 years). Following the measurement of visual acuity and intraocular pressure, the RNFL thickness of the right eye was assessed using optical coherence tomography (Optovue, Inc., Fremont, CA, USA), and contrast sensitivity was measured with the CSV-1000E (Vector Vision, Dayton, OH, USA). Following a 5-minute period of dark adaptation, both static and dynamic pupillographic parameters were assessed using the Sirius corneal topography device (Sirius, CSO, Florence, Italy). There was no statistically significant difference between the groups in terms of age and sex (p = 0.126 and p = 0.579, respectively). RNFL thickness in the superior, inferior, nasal, and temporal quadrants of the right eye were as follows for Parkinson's and control groups, respectively: 133.6 ± 18.03 vs. 144.73 ± 17.44 μm (p = 0.03), 122.0 ± 14.47 vs. 134.96 ± 25.28 μm (p = 0.031), 67.76 ± 12.05 vs. 74.65 ± 12.05 μm (p = 0.047), and 66.36 ± 8.72 vs. 72.77 ± 14.0 μm (p = 0.057). A statistically significant thinning was observed in all quadrants except the temporal quadrant in Parkinson's patients (Fig. 1). Contrast sensitivity was significantly lower in the Parkinson's group across all spatial frequencies compared to controls (p = 0.03, 0.01, < 0.01, and 0.02, respectively) (Fig. 2). Although pupil sizes were smaller in the Parkinson's group under scotopic, mesopic, and photopic conditions in static pupillography, the differences were not statistically significant (p > 0.05). Similarly, in dynamic pupillography, the pupil diameters at 0, 2, 4, 8, 12, and 16 s were smaller in the Parkinson's group, but no statistically significant differences were found between the groups (p > 0.05) (Fig. 3). While a significant reduction in RNFL thickness and contrast sensitivity was observed in patients with Parkinson's disease, static and dynamic pupillographic parameters did not differ significantly between the groups. Therefore, the prognostic utility of pupillography in Parkinson's disease remains inconclusive and should be further investigated in larger and longitudinal studies.
- 8 July 2025
- Vol. 25 (1) , 397
Open AccessPupillographic evaluation accompanying structural and functional assessment of the optic nerve in patients with Parkinson's disease.
To evaluate static and dynamic pupillary functions, contrast sensitivity, and retinal nerve fiber layer (RNFL) thickness in patients with Parkinson's disease. The study included 25 right eyes of patients with Parkinson's disease (mean age: 67.88 ± 9.40 years) and 26 right eyes of age- and sex-matched healthy controls (mean age: 64.15 ± 7.60 years). Following the measurement of visual acuity and intraocular pressure, the RNFL thickness of the right eye was assessed using optical coherence tomography (Optovue, Inc., Fremont, CA, USA), and contrast sensitivity was measured with the CSV-1000E (Vector Vision, Dayton, OH, USA). Following a 5-minute period of dark adaptation, both static and dynamic pupillographic parameters were assessed using the Sirius corneal topography device (Sirius, CSO, Florence, Italy). There was no statistically significant difference between the groups in terms of age and sex (p = 0.126 and p = 0.579, respectively). RNFL thickness in the superior, inferior, nasal, and temporal quadrants of the right eye were as follows for Parkinson's and control groups, respectively: 133.6 ± 18.03 vs. 144.73 ± 17.44 μm (p = 0.03), 122.0 ± 14.47 vs. 134.96 ± 25.28 μm (p = 0.031), 67.76 ± 12.05 vs. 74.65 ± 12.05 μm (p = 0.047), and 66.36 ± 8.72 vs. 72.77 ± 14.0 μm (p = 0.057). A statistically significant thinning was observed in all quadrants except the temporal quadrant in Parkinson's patients (Fig. 1). Contrast sensitivity was significantly lower in the Parkinson's group across all spatial frequencies compared to controls (p = 0.03, 0.01, < 0.01, and 0.02, respectively) (Fig. 2). Although pupil sizes were smaller in the Parkinson's group under scotopic, mesopic, and photopic conditions in static pupillography, the differences were not statistically significant (p > 0.05). Similarly, in dynamic pupillography, the pupil diameters at 0, 2, 4, 8, 12, and 16 s were smaller in the Parkinson's group, but no statistically significant differences were found between the groups (p > 0.05) (Fig. 3). While a significant reduction in RNFL thickness and contrast sensitivity was observed in patients with Parkinson's disease, static and dynamic pupillographic parameters did not differ significantly between the groups. Therefore, the prognostic utility of pupillography in Parkinson's disease remains inconclusive and should be further investigated in larger and longitudinal studies.
- 8 September 2021
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 32 (4) , 2173-2180
Static and dynamic pupillary characteristics in multiple sclerosis
To examine the static and dynamic pupillary functions with automated pupillography in multiple sclerosis (MS) patients with preserved visual acuity. Forty-seven MS patients with preserved visual acuity were included in the study group and 43 healthy volunteers in the control group. The visual evoked potential of the patients was obtained. After routine ophthalmologic examination contrast sensitivity and the retinal nerve fiber layer (RNFL) thickness were measured. Finally scotopic, mesopic, and photopic pupillographies followed by dynamic pupillography were undertaken, and the pupillary dilatation speed was calculated. The contrast sensitivity and RNFL thickness of the MS group were significantly lower than those of the control group (p < 0.05; for both). In the MS and control groups, the scotopic pupil diameters were 5.48 ± 1.03 and 5.28 ± 0.78 mm, mesopic pupil diameters were 4.82 ± 0.83 and 4.48 ± 0.70 mm, and photopic pupil diameters were 3.84 ± 0.79 and 3.42 ± 0.49 mm, respectively (p = 0.315, p = 0.044, and p = 0.004, respectively). In dynamic pupillography, the pupil in the MS group was more dilated than control group at all time sections examined except the sixth second (p < 0.05; for all). Although the mean pupillary dilation speed in the first second was higher in the MS group (p = 0.044), there was no significant difference between the groups for the other time intervals examined (p > 0.05; for all). There was no correlation between pupillary parameters and P100-wave latency, RNFL thickness, or contrast sensitivity (p > 0.05; for all). Static and dynamic pupillary functions may be affected in MS patients with preserved visual acuity. Although scotopic pupillary functions are preserved, mesopic, and photopic pupil functions are weakened.
- 8 September 2021
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 32 (4) , 2173-2180
Static and dynamic pupillary characteristics in multiple sclerosis
To examine the static and dynamic pupillary functions with automated pupillography in multiple sclerosis (MS) patients with preserved visual acuity. Forty-seven MS patients with preserved visual acuity were included in the study group and 43 healthy volunteers in the control group. The visual evoked potential of the patients was obtained. After routine ophthalmologic examination contrast sensitivity and the retinal nerve fiber layer (RNFL) thickness were measured. Finally scotopic, mesopic, and photopic pupillographies followed by dynamic pupillography were undertaken, and the pupillary dilatation speed was calculated. The contrast sensitivity and RNFL thickness of the MS group were significantly lower than those of the control group (p < 0.05; for both). In the MS and control groups, the scotopic pupil diameters were 5.48 ± 1.03 and 5.28 ± 0.78 mm, mesopic pupil diameters were 4.82 ± 0.83 and 4.48 ± 0.70 mm, and photopic pupil diameters were 3.84 ± 0.79 and 3.42 ± 0.49 mm, respectively (p = 0.315, p = 0.044, and p = 0.004, respectively). In dynamic pupillography, the pupil in the MS group was more dilated than control group at all time sections examined except the sixth second (p < 0.05; for all). Although the mean pupillary dilation speed in the first second was higher in the MS group (p = 0.044), there was no significant difference between the groups for the other time intervals examined (p > 0.05; for all). There was no correlation between pupillary parameters and P100-wave latency, RNFL thickness, or contrast sensitivity (p > 0.05; for all). Static and dynamic pupillary functions may be affected in MS patients with preserved visual acuity. Although scotopic pupillary functions are preserved, mesopic, and photopic pupil functions are weakened.