Noor Asyikin Sulaiman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Noor Asyikin Sulaiman has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Azdiana Md Yusop
Fakulti Teknologi dan Kejuruteraan Elektronik dan Komputer, Centre for Telecommunication Research and Innovation (CeTRI), Universiti Teknikal Malaysia Melaka, Durian Tunggal, Malaysia
2 shared publications - Ahmad Sadhiqin Mohd Isira
Universiti Teknikal Malaysia Melaka
1 shared publication - Hayati Abdullah
Universiti Teknologi Malaysia
1 shared publication - Muhammad Noorazlan Shah Zainudin
Universiti Teknikal Malaysia Melaka
1 shared publication - Pauzi Abdullah
Universiti Teknologi Malaysia
1 shared publication - Ramizi Mohamed
Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Bangi, Malaysia
1 shared publication
Latest Publications
- 7 September 2021
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 10809-10822
Performance analysis of shapeable-maximum power point tracking technique from thermoelectric-solar hybrid energy harvesting sources on mobile devices
In this study, the performance analysis of the thermoelectric-solar (TEM-SA) hybrid energy harvesting system is presented. The proposed system is analyzed for continuous and discontinuous load condition and mobile devices as a load. In this feed forward type of controller, Inverse Dynamic Analysis Input Shaper (IDAIS) is introduced to shape the unsteady response behavior to become stable input and is named as Shapeable MPPT (SMPPT). The experimental analysis is done to verify the performance of the new arrangement proposed circuit of HEHS which is used only one MPPT board. An initial test is made in determining which energy-efficient sources are capable to produce the highest output. Then the device that produces the highest output is connected to the new arrangement proposed circuit incorporated SMPPT unit, the converter, and the energy storage. With constant source supply, full charging time obtained for mobile phone is 4 hours and 30 minutes which is equivalent to the charging period using the normal alternating current sources. Greater focus is then given to the charging time for some types of mobile phones that have different battery capacity mAH. From the verification results, it is found that the load that having lowest mAh values steadily able to reach the full charging period faster than the others.
- 7 September 2021
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 10809-10822
Performance analysis of shapeable-maximum power point tracking technique from thermoelectric-solar hybrid energy harvesting sources on mobile devices
In this study, the performance analysis of the thermoelectric-solar (TEM-SA) hybrid energy harvesting system is presented. The proposed system is analyzed for continuous and discontinuous load condition and mobile devices as a load. In this feed forward type of controller, Inverse Dynamic Analysis Input Shaper (IDAIS) is introduced to shape the unsteady response behavior to become stable input and is named as Shapeable MPPT (SMPPT). The experimental analysis is done to verify the performance of the new arrangement proposed circuit of HEHS which is used only one MPPT board. An initial test is made in determining which energy-efficient sources are capable to produce the highest output. Then the device that produces the highest output is connected to the new arrangement proposed circuit incorporated SMPPT unit, the converter, and the energy storage. With constant source supply, full charging time obtained for mobile phone is 4 hours and 30 minutes which is equivalent to the charging period using the normal alternating current sources. Greater focus is then given to the charging time for some types of mobile phones that have different battery capacity mAH. From the verification results, it is found that the load that having lowest mAh values steadily able to reach the full charging period faster than the others.
- Open Access
- 1 March 2020
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Artificial Intelligence (IJ-AI)
- Vol. 9 (1) , 109-116
Fault detection for air conditioning system using machine learning
Air conditioning system is a complex system and consumes the most energy in a building. Any fault in the system operation such as cooling tower fan faulty, compressor failure, damper stuck, etc. could lead to energy wastage and reduction in the system’s coefficient of performance (COP). Due to the complexity of the air conditioning system, detecting those faults is hard as it requires exhaustive inspections. This paper consists of two parts; i) to investigate the impact of different faults related to the air conditioning system on COP and ii) to analyse the performances of machine learning algorithms to classify those faults. Three supervised learning classifier models were developed, which were deep learning, support vector machine (SVM) and multi-layer perceptron (MLP). The performances of each classifier were investigated in terms of six different classes of faults. Results showed that different faults give different negative impacts on the COP. Also, the three supervised learning classifier models able to classify all faults for more than 94%, and MLP produced the highest accuracy and precision among all.
- 1 March 2020
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Artificial Intelligence (IJ-AI)
- Vol. 9 (1) , 109-116
Open AccessFault detection for air conditioning system using machine learning
Air conditioning system is a complex system and consumes the most energy in a building. Any fault in the system operation such as cooling tower fan faulty, compressor failure, damper stuck, etc. could lead to energy wastage and reduction in the system’s coefficient of performance (COP). Due to the complexity of the air conditioning system, detecting those faults is hard as it requires exhaustive inspections. This paper consists of two parts; i) to investigate the impact of different faults related to the air conditioning system on COP and ii) to analyse the performances of machine learning algorithms to classify those faults. Three supervised learning classifier models were developed, which were deep learning, support vector machine (SVM) and multi-layer perceptron (MLP). The performances of each classifier were investigated in terms of six different classes of faults. Results showed that different faults give different negative impacts on the COP. Also, the three supervised learning classifier models able to classify all faults for more than 94%, and MLP produced the highest accuracy and precision among all.