Yoriko Horiguchi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoriko Horiguchi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Yukiko Morita
Department of Cardiology, National Hospital Organization Sagamihara National Hospital, 18-1 Sakuradai, Minami-ku, Sagamihara City, Kanagawa, 252-0392, Japan
3 shared publicationsHirooki Matsushita
Department of Cardiology, National Hospital Organization Sagamihara National Hospital, 18-1 Sakuradai, Minami-ku, Sagamihara City, Kanagawa, 252-0392, Japan
2 shared publicationsMasahiko Kanna
Department of Cardiology, National Hospital Organization Sagamihara National Hospital, 18-1 Sakuradai, Minami-ku, Sagamihara City, Kanagawa, 252-0392, Japan
2 shared publicationsRyo Sasaki
Department of Radiology, National Hospital Organization Sagamihara National Hospital, Kanagawa, Japan
2 shared publicationsShinnosuke Kikuchi
Department of Cardiology, National Hospital Organization Sagamihara National Hospital, 18-1 Sakuradai, Minami-ku, Sagamihara City, Kanagawa, 252-0392, Japan
2 shared publicationsTomohiro Ueda
Department of Radiology, National Hospital Organization Sagamihara National Hospital, Kanagawa, Japan
2 shared publications
Latest Publications
- Open Access
- 8 September 2021
- Published by Springer Nature in Renal Replacement Therapy
- Vol. 7 (1) , 1-8
Prognosis of hemodialysis patients with progressive aortic stenosis: a prospective cohort study
Background: Whether progressive mild to moderate aortic stenosis in hemodialysis patients influences their prognosis has not been elucidated. This prospective cohort study explored whether progressive aortic stenosis predicted the rate of cardiac events and mortality in those patients. Methods: A total of 283 consecutive hemodialysis patients (no aortic stenosis, 248; progressive aortic stenosis, 35) underwent echocardiography for assessment of aortic stenosis, with a median follow-up period of 4.1 years. Study endpoints were cardiac events, all-cause mortality, and cardiac death. Kaplan–Meier analysis and multivariate Cox proportional hazard analysis were performed to estimate cardiac events, all-cause mortality, and cardiac death. Results: Cumulative cardiac event rate, all-cause mortality rate, and the rate of cardiac death at 3-year follow-up were 44.9%, 40.5%, and 26.4% in patients with progressive aortic stenosis and 22.1%, 19.0%, and 7.5% in those without aortic stenosis, respectively. Kaplan–Meier analysis demonstrated the cumulative rates of cardiac events and all-cause mortality. And cardiac death was significantly higher in patients with progressive aortic stenosis than in those without aortic stenosis. Multivariate Cox proportional hazard analysis revealed that progressive aortic stenosis was predictive of cardiac events (adjusted hazard ratio 2.47; 95% confidence interval 1.38–4.39) and cardiac death (adjusted hazard ratio 4.21; 95% confidence interval 2.10–8.46). Age, physical activity, C-reactive protein, and serum albumin levels—but not progressive aortic stenosis—predicted all-cause mortality. Conclusions: The rates of cardiac events and cardiac death were higher in hemodialysis patients with progressive aortic stenosis than in those without aortic stenosis. Furthermore, progressive aortic stenosis predicted cardiac events and cardiac death. Compared with those without aortic stenosis, patients with progressive aortic stenosis had higher all-cause mortality, which was related to their comorbidities. Trial registration This study was retrospectively registered with University Hospital Medical Information Network Clinical Trials Registry (registration number, UMIN 000024023) at September 12th, 2016.
- 8 September 2021
- Published by Springer Nature in Renal Replacement Therapy
- Vol. 7 (1) , 1-8
Open AccessPrognosis of hemodialysis patients with progressive aortic stenosis: a prospective cohort study
Background: Whether progressive mild to moderate aortic stenosis in hemodialysis patients influences their prognosis has not been elucidated. This prospective cohort study explored whether progressive aortic stenosis predicted the rate of cardiac events and mortality in those patients. Methods: A total of 283 consecutive hemodialysis patients (no aortic stenosis, 248; progressive aortic stenosis, 35) underwent echocardiography for assessment of aortic stenosis, with a median follow-up period of 4.1 years. Study endpoints were cardiac events, all-cause mortality, and cardiac death. Kaplan–Meier analysis and multivariate Cox proportional hazard analysis were performed to estimate cardiac events, all-cause mortality, and cardiac death. Results: Cumulative cardiac event rate, all-cause mortality rate, and the rate of cardiac death at 3-year follow-up were 44.9%, 40.5%, and 26.4% in patients with progressive aortic stenosis and 22.1%, 19.0%, and 7.5% in those without aortic stenosis, respectively. Kaplan–Meier analysis demonstrated the cumulative rates of cardiac events and all-cause mortality. And cardiac death was significantly higher in patients with progressive aortic stenosis than in those without aortic stenosis. Multivariate Cox proportional hazard analysis revealed that progressive aortic stenosis was predictive of cardiac events (adjusted hazard ratio 2.47; 95% confidence interval 1.38–4.39) and cardiac death (adjusted hazard ratio 4.21; 95% confidence interval 2.10–8.46). Age, physical activity, C-reactive protein, and serum albumin levels—but not progressive aortic stenosis—predicted all-cause mortality. Conclusions: The rates of cardiac events and cardiac death were higher in hemodialysis patients with progressive aortic stenosis than in those without aortic stenosis. Furthermore, progressive aortic stenosis predicted cardiac events and cardiac death. Compared with those without aortic stenosis, patients with progressive aortic stenosis had higher all-cause mortality, which was related to their comorbidities. Trial registration This study was retrospectively registered with University Hospital Medical Information Network Clinical Trials Registry (registration number, UMIN 000024023) at September 12th, 2016.
- 26 August 2015
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 29 (10) , 890-896
Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction
The purpose of this study is to evaluate whether prone myocardial perfusion single-photon emission computed tomography (MPS) with thallium-201 acquired through a variable-focus collimator (IQ-SPECT) can correct for soft-tissue attenuation. Thirty-nine patients underwent thallium-201 stress MPS with IQ-SPECT. Delayed images acquired with the patients in the prone position were compared with delayed images obtained with the patients in the supine position with computed tomography-derived attenuation correction (CTAC) (S-CTAC images) or without CTAC (S-NCTAC images). Quantitative tracer uptake (QTU) and semi-quantitative defect scores were determined for the 17 standard myocardial segments. Segments were categorized into anterior–anteroseptal, lateral, inferior, and apex, and areas with defect decision were determined by using the defect scores. Image quality in the prone images was similar to that of S-NCTAC and S-CTAC images. In male patients, QTU in prone images was equivalent to that in S-CTAC images in the anterior–anteroseptal area, but was significantly lower than that in S-CTAC images in the inferior area. In female patients, QTU in prone images was similar to that in S-CTAC images in the anterior–anteroseptal, lateral, and inferior areas. In male and in female patients, QTU in the apex was significantly greater in the prone images than that in the S-CTAC images. In the combined male and female patient group, the defect decision for prone images was similar to that for S-CTAC images in the anterior–anteroseptal, lateral, and inferior areas. Apical defects were observed more frequently in S-CTAC images than in prone or S-NCTAC images. Fewer artificial defects were observed in the apex of images acquired by prone imaging than by S-CTAC imaging. Prone images improved attenuation and had similar defect decision as S-CTAC images in the anterior–anteroseptal, lateral, and inferior areas.
- 26 August 2015
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 29 (10) , 890-896
Validation of prone myocardial perfusion SPECT with a variable-focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction
The purpose of this study is to evaluate whether prone myocardial perfusion single-photon emission computed tomography (MPS) with thallium-201 acquired through a variable-focus collimator (IQ-SPECT) can correct for soft-tissue attenuation. Thirty-nine patients underwent thallium-201 stress MPS with IQ-SPECT. Delayed images acquired with the patients in the prone position were compared with delayed images obtained with the patients in the supine position with computed tomography-derived attenuation correction (CTAC) (S-CTAC images) or without CTAC (S-NCTAC images). Quantitative tracer uptake (QTU) and semi-quantitative defect scores were determined for the 17 standard myocardial segments. Segments were categorized into anterior–anteroseptal, lateral, inferior, and apex, and areas with defect decision were determined by using the defect scores. Image quality in the prone images was similar to that of S-NCTAC and S-CTAC images. In male patients, QTU in prone images was equivalent to that in S-CTAC images in the anterior–anteroseptal area, but was significantly lower than that in S-CTAC images in the inferior area. In female patients, QTU in prone images was similar to that in S-CTAC images in the anterior–anteroseptal, lateral, and inferior areas. In male and in female patients, QTU in the apex was significantly greater in the prone images than that in the S-CTAC images. In the combined male and female patient group, the defect decision for prone images was similar to that for S-CTAC images in the anterior–anteroseptal, lateral, and inferior areas. Apical defects were observed more frequently in S-CTAC images than in prone or S-NCTAC images. Fewer artificial defects were observed in the apex of images acquired by prone imaging than by S-CTAC imaging. Prone images improved attenuation and had similar defect decision as S-CTAC images in the anterior–anteroseptal, lateral, and inferior areas.
- 20 July 2014
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 28 (8) , 707-715
Validation of a short-scan-time imaging protocol for thallium-201 myocardial SPECT with a multifocal collimator
IQ-SPECT (Siemens AG, Munich, Germany) is a highly sensitive single-photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) system that uses a multifocal collimator. We searched for a suitable protocol for short-time imaging by IQ-SPECT in thallium-201 (Tl-201) MPI by evaluating phantom images and also by comparing human IQ-SPECT images with conventional SPECT images as reference standards. We assessed the image quality using the normalized mean square error (NMSE) and drew up count profiles in Tl-201 SPECT images acquired with IQ-SPECT in a phantom study. We also performed Tl-201 stress myocardial SPECT/CT in 21 patients and compared delayed images acquired by using IQ-SPECT with 36 or 17 views per head with images obtained by using conventional SPECT. The NMSE of SPECT images from IQ-SPECT with 36 views was approximately one-fifth of that with 17 views. The myocardial count profile of images with 17 views was lower than those of images with 36 or 104 views in some regions. Defect scores were significantly lower, and image quality scores higher, in images from conventional SPECT than in those from IQ-SPECT with 17 views. Defect scores and image quality scores were equivalent in images from conventional SPECT and those from IQ-SPECT with 36 views. Agreement with the results of conventional SPECT in terms of coronary artery territory-based defect judgment was the best in IQ-SPECT with 36 views with computed tomography-derived attenuation correction (CTAC): the kappa values for IQ-SPECT with 36 views were 0.76 (without CTAC) and 0.83 (with CTAC), and those for IQ-SPECT with 17 views were 0.62 (without CTAC) and 0.59 (with CTAC). The difference in quantitative tracer uptake between conventional SPECT images and IQ-SPECT images was significantly greater for IQ-SPECT images with 17 views than for those with 36 views. Scanning with 36 views per head with CTAC may be appropriate for Tl-201 MPI using IQ-SPECT, because it provides images equivalent to those using conventional SPECT.
- 20 July 2014
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 28 (8) , 707-715
Validation of a short-scan-time imaging protocol for thallium-201 myocardial SPECT with a multifocal collimator
IQ-SPECT (Siemens AG, Munich, Germany) is a highly sensitive single-photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) system that uses a multifocal collimator. We searched for a suitable protocol for short-time imaging by IQ-SPECT in thallium-201 (Tl-201) MPI by evaluating phantom images and also by comparing human IQ-SPECT images with conventional SPECT images as reference standards. We assessed the image quality using the normalized mean square error (NMSE) and drew up count profiles in Tl-201 SPECT images acquired with IQ-SPECT in a phantom study. We also performed Tl-201 stress myocardial SPECT/CT in 21 patients and compared delayed images acquired by using IQ-SPECT with 36 or 17 views per head with images obtained by using conventional SPECT. The NMSE of SPECT images from IQ-SPECT with 36 views was approximately one-fifth of that with 17 views. The myocardial count profile of images with 17 views was lower than those of images with 36 or 104 views in some regions. Defect scores were significantly lower, and image quality scores higher, in images from conventional SPECT than in those from IQ-SPECT with 17 views. Defect scores and image quality scores were equivalent in images from conventional SPECT and those from IQ-SPECT with 36 views. Agreement with the results of conventional SPECT in terms of coronary artery territory-based defect judgment was the best in IQ-SPECT with 36 views with computed tomography-derived attenuation correction (CTAC): the kappa values for IQ-SPECT with 36 views were 0.76 (without CTAC) and 0.83 (with CTAC), and those for IQ-SPECT with 17 views were 0.62 (without CTAC) and 0.59 (with CTAC). The difference in quantitative tracer uptake between conventional SPECT images and IQ-SPECT images was significantly greater for IQ-SPECT images with 17 views than for those with 36 views. Scanning with 36 views per head with CTAC may be appropriate for Tl-201 MPI using IQ-SPECT, because it provides images equivalent to those using conventional SPECT.
- 23 September 2010
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 38 (2) , 221-229
123I-MIBG imaging detects cardiac involvement and predicts cardiac events in Churg-Strauss syndrome
In Churg-Strauss syndrome (CSS) it is important to detect cardiac involvement, which predicts poor prognosis. This study evaluated whether 123I-metaiodobenzylguanidine (MIBG) scintigraphy could detect cardiac damage and predict cardiac events in CSS.
- 23 September 2010
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 38 (2) , 221-229
123I-MIBG imaging detects cardiac involvement and predicts cardiac events in Churg-Strauss syndrome
In Churg-Strauss syndrome (CSS) it is important to detect cardiac involvement, which predicts poor prognosis. This study evaluated whether 123I-metaiodobenzylguanidine (MIBG) scintigraphy could detect cardiac damage and predict cardiac events in CSS.