Ancuta Ioana Friismose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ancuta Ioana Friismose has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Bo Mussmann
Department of Radiology, Odense University Hospital, Sdr. Boulevard 29, 5000 Odense C, Denmark; Department of Clinical Research, University of Southern Denmark, Campusvej 55, 5220, Odense, Denmark; Department of Life Sciences and Health, Oslo Metropolitan University, Pilestedet 48, N-0130 Oslo, Norway
8 shared publications - Emi Hojo
Department of Radiology, Mayo Clinic, Rochester, MN
7 shared publications - Frantz Rom Poulsen
Department of Neurosurgery, Odense University Hospital, 5000 Odense, Denmark
7 shared publications - Jan Saip Aunan-Diop
Department of Neurosurgery, Odense University Hospital, Denmark
7 shared publications - Bo Halle
Department of Neurosurgery, Odense University Hospital, Odense, Denmark
6 shared publications - Ziying Yin
Department of Radiology, Mayo Clinic, Rochester, USA
6 shared publications
Latest Publications
- Open Access
- 14 July 2026
- Published by Elsevier in SSRN Electronic Journal
Meningiomas Are Composites of Distinct Viscoelastic Material Regimes Detectable in vivo by MR Elastography
Background: Meningioma mechanical behavior is central to surgical resection but is typically characterized as a single bulk stiffness, discarding the intratumoral heterogeneity that governs how tissue is cut, aspirated, and dissected. We treated meningioma tissue as a natural viscoelastic material and asked whether its mechanical architecture (i) resolves into distinct, structurally interpretable regimes and (ii) is expressed in the in vivo elastographic signal.Methods: Oscillatory shear rheometry was performed on 169 tissue samples from 27 meningiomas. Slice-level viscoelastic features defined reproducible mechanical regimes, which were further characterized by their strain-dependent response (yield strain, strain-stiffening, low-strain damping). Cluster validity was assessed by silhouette coefficient and bootstrap stability. In an imaging-linked subset of 19 lesions, preoperative MR elastography (MRE) maps of |G*|, G′, and G″ were compared with the ex vivo composition using construct-aligned correlations with bootstrap confidence intervals, and out-of-sample reconstruction was evaluated by leave-one-out cross-validation.Results: As the primary finding, rheometry resolved three interpretable mechanical regimes: a compliant, high-damping state that stiffens under strain (A); an intermediate, loss-modulus-dominated state (B); and a rare, stiff, low-damping state that yields abruptly at very low strain (C). All strain-response descriptors differed across regimes (p<0.001), and each tumor’s behavior was defined by regime composition rather than a bulk modulus. Cluster validity indicated that the most stable structure is a two-way stiff-versus-soft split; the three-regime solution was retained because it separates two softer regimes (A and B) with distinct strain-response behavior. As a secondary finding, G″-related MRE features reflected the loss-associated (A/B) compositional axis (mean G″ versus regime B burden ρ=0.76, 95% CI 0.41–0.96). Individual-lesion prediction of composition was not established (held-out ρ=0.39, 95% CI −0.16–0.75) and, together with spatial (habitat) mapping and detection of the rare hard regime, remained exploratory. Regime composition co-varied moderately with WHO grade.Conclusions: Meningiomas are compositional viscoelastic materials whose regime structure is mechanistically interpretable and whose loss-modulus axis is non-invasively detectable, shifting tumor mechanical assessment from bulk stiffness toward a material-architecture framework relevant to surgical planning.
- 14 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMeningiomas Are Composites of Distinct Viscoelastic Material Regimes Detectable in vivo by MR Elastography
Background: Meningioma mechanical behavior is central to surgical resection but is typically characterized as a single bulk stiffness, discarding the intratumoral heterogeneity that governs how tissue is cut, aspirated, and dissected. We treated meningioma tissue as a natural viscoelastic material and asked whether its mechanical architecture (i) resolves into distinct, structurally interpretable regimes and (ii) is expressed in the in vivo elastographic signal.Methods: Oscillatory shear rheometry was performed on 169 tissue samples from 27 meningiomas. Slice-level viscoelastic features defined reproducible mechanical regimes, which were further characterized by their strain-dependent response (yield strain, strain-stiffening, low-strain damping). Cluster validity was assessed by silhouette coefficient and bootstrap stability. In an imaging-linked subset of 19 lesions, preoperative MR elastography (MRE) maps of |G*|, G′, and G″ were compared with the ex vivo composition using construct-aligned correlations with bootstrap confidence intervals, and out-of-sample reconstruction was evaluated by leave-one-out cross-validation.Results: As the primary finding, rheometry resolved three interpretable mechanical regimes: a compliant, high-damping state that stiffens under strain (A); an intermediate, loss-modulus-dominated state (B); and a rare, stiff, low-damping state that yields abruptly at very low strain (C). All strain-response descriptors differed across regimes (p<0.001), and each tumor’s behavior was defined by regime composition rather than a bulk modulus. Cluster validity indicated that the most stable structure is a two-way stiff-versus-soft split; the three-regime solution was retained because it separates two softer regimes (A and B) with distinct strain-response behavior. As a secondary finding, G″-related MRE features reflected the loss-associated (A/B) compositional axis (mean G″ versus regime B burden ρ=0.76, 95% CI 0.41–0.96). Individual-lesion prediction of composition was not established (held-out ρ=0.39, 95% CI −0.16–0.75) and, together with spatial (habitat) mapping and detection of the rare hard regime, remained exploratory. Regime composition co-varied moderately with WHO grade.Conclusions: Meningiomas are compositional viscoelastic materials whose regime structure is mechanistically interpretable and whose loss-modulus axis is non-invasively detectable, shifting tumor mechanical assessment from bulk stiffness toward a material-architecture framework relevant to surgical planning.
- Open Access
Directional interface mechanics using magnetic resonance elastography predicts focal tumor recurrence in glioblastomas
Glioblastoma progression is spatially heterogeneous, but conventional imaging provides limited information about where subsequent tumor progression is likely to occur. We developed a directional magnetic resonance elastography (MRE) framework to test whether local post-treatment tumor–brain interface mechanics are associated with later spatial tumor progression. In a secondary analysis of a prospectively acquired glioblastoma cohort, wedge-level viscoelastic instability features were extracted from the first post-treatment MRE scan and related to novel tumor burden on the second post-treatment scan after excluding tumor already present on pretreatment or first post-treatment imaging. Nine patients had longitudinal imaging suitable for spatial comparison; six lesions showed net interval growth and were included in the primary wedge-level directional analysis, while three non-growing lesions were retained for descriptive comparison. In growing lesions, several directional mechanical features were descriptively associated with later novel tumor burden. In cluster-aware models accounting for within-patient dependence among wedges, mean Δtanδ showed the most consistent association with later wedge-level novel tumor fraction across mixed-effects and generalized estimating equation analyses. Associations were directionally stable across wedge-width sensitivity analyses. These findings provide proof of principle that post-treatment glioblastoma interface mechanics contain spatially resolved information related to where later tumor emergence occurs, supporting further validation of directional MRE as a framework for longitudinal mapping of progression geometry.
Open AccessDirectional interface mechanics using magnetic resonance elastography predicts focal tumor recurrence in glioblastomas
Glioblastoma progression is spatially heterogeneous, but conventional imaging provides limited information about where subsequent tumor progression is likely to occur. We developed a directional magnetic resonance elastography (MRE) framework to test whether local post-treatment tumor–brain interface mechanics are associated with later spatial tumor progression. In a secondary analysis of a prospectively acquired glioblastoma cohort, wedge-level viscoelastic instability features were extracted from the first post-treatment MRE scan and related to novel tumor burden on the second post-treatment scan after excluding tumor already present on pretreatment or first post-treatment imaging. Nine patients had longitudinal imaging suitable for spatial comparison; six lesions showed net interval growth and were included in the primary wedge-level directional analysis, while three non-growing lesions were retained for descriptive comparison. In growing lesions, several directional mechanical features were descriptively associated with later novel tumor burden. In cluster-aware models accounting for within-patient dependence among wedges, mean Δtanδ showed the most consistent association with later wedge-level novel tumor fraction across mixed-effects and generalized estimating equation analyses. Associations were directionally stable across wedge-width sensitivity analyses. These findings provide proof of principle that post-treatment glioblastoma interface mechanics contain spatially resolved information related to where later tumor emergence occurs, supporting further validation of directional MRE as a framework for longitudinal mapping of progression geometry.
- Open Access
Information-Guided Parameter Optimisation for MR Elastography Radiomics
Mechanical properties of biological tissues vary across spatial scales, yet radiomics typically relies on fixed, heuristic choices for neighbourhood size, kernel geometry, and spectral content - choices that can silently reshape the feature space before any modelling begins. We introduce a label-free, information-theoretic framework for selecting extraction parameters in multi-frequency MRE radiomics. For each configuration θ - neighbourhood radius r, kernel geometry k (sphere or shell), and frequency subset f - we extract a radiomics feature matrix and score it using an objective J(θ) that integrates distributional richness (Shannon entropy), cross-frequency coherence (canonical correlation), inter-feature redundancy (Spearman correlation), and bootstrap stability. We evaluate 121 configurations per tissue in multi-frequency MRE (30-60 Hz) of human brain, liver, and a calibrated phantom, and test robustness using 10,000 Dirichlet-sampled objective weightings. Across tissues, neighbourhood aggregation is consistently preferred over voxel-wise extraction, outperforming the no-neighbourhood baseline in 98.4-100% of weightings. External validation in 100 independent brain scans acquired with a different protocol and wider frequency range (20-90 Hz) confirms a reproducible mesoscopic plateau at r = 3-5 (9-15 mm), with a modal optimum at r = 4; omitting neighbourhood analysis reduces J(θ) by 38% relative to each subject’s optimum. Frequency-subset preferences replicate across datasets, with lower frequencies most frequently selected for brain. By turning ad hoc extraction choices into an outcome-free optimisation step, this framework improves reproducibility, reduces sensitivity to heuristic parameter choices, and generalises across acquisition protocols and imaging sites.
Open AccessInformation-Guided Parameter Optimisation for MR Elastography Radiomics
Mechanical properties of biological tissues vary across spatial scales, yet radiomics typically relies on fixed, heuristic choices for neighbourhood size, kernel geometry, and spectral content - choices that can silently reshape the feature space before any modelling begins. We introduce a label-free, information-theoretic framework for selecting extraction parameters in multi-frequency MRE radiomics. For each configuration θ - neighbourhood radius r, kernel geometry k (sphere or shell), and frequency subset f - we extract a radiomics feature matrix and score it using an objective J(θ) that integrates distributional richness (Shannon entropy), cross-frequency coherence (canonical correlation), inter-feature redundancy (Spearman correlation), and bootstrap stability. We evaluate 121 configurations per tissue in multi-frequency MRE (30-60 Hz) of human brain, liver, and a calibrated phantom, and test robustness using 10,000 Dirichlet-sampled objective weightings. Across tissues, neighbourhood aggregation is consistently preferred over voxel-wise extraction, outperforming the no-neighbourhood baseline in 98.4-100% of weightings. External validation in 100 independent brain scans acquired with a different protocol and wider frequency range (20-90 Hz) confirms a reproducible mesoscopic plateau at r = 3-5 (9-15 mm), with a modal optimum at r = 4; omitting neighbourhood analysis reduces J(θ) by 38% relative to each subject’s optimum. Frequency-subset preferences replicate across datasets, with lower frequencies most frequently selected for brain. By turning ad hoc extraction choices into an outcome-free optimisation step, this framework improves reproducibility, reduces sensitivity to heuristic parameter choices, and generalises across acquisition protocols and imaging sites.
- Open Access
Differentiating radiation necrosis from recurrent brain metastases using magnetic resonance elastography
Background: Conventional MRI cannot reliably distinguish radiation necrosis (RN) from recurrent metastasis after cranial radiotherapy, as both can show similar enhancement despite different biology. We tested whether these entities are mechanically non-equivalent in vivo and separable by MRE-derived viscoelastic metrics and perilesional interface-instability features. Methods: In a prospective, histopathology-anchored cohort, 11 post-radiotherapy enhancing lesions were classified as RN (n=3) or recurrent/progressive tumor (n=8). MRE was acquired at 3.0 T with single-frequency 60-Hz excitation to derive storage modulus (G′), loss modulus (G″), and complex shear modulus magnitude (|G*|). Co-primary endpoints were median tumor G′ and |G*|, each tested one-sided (RN > tumor) with Holm correction across the two co-primary tests. Median tumor G″ was tested two-sided. A prespecified secondary 6-endpoint family (absolute and tumor/NAWM-normalized G′, G″, and |G*|) was analyzed with Benjamini–Hochberg FDR control. Exploratory instability mapping in a 0–6 mm peritumoral shell generated interface-topology metrics, including convexity. Results: Absolute tumor-core medians were higher in RN than tumor for |G*| (1.79 vs 1.32 kPa; Cliff’s δ=0.67; q=0.10), G′ (1.62 vs 1.09 kPa; δ=0.50; q=0.14), and G″ (0.81 vs 0.46 kPa; δ=0.75; q=0.10). NAWM normalization improved separation: tumor/NAWM |G*| (2.26 vs 1.41; δ=0.92; q=0.04) and tumor/NAWM G″ (2.67 vs 0.87; δ=1.00; q=0.04) were FDR-significant. Convexity also differentiated RN from tumor (0.49 vs 0.36; δ=1.00; MWU p=0.01). Conclusions: Tumor/NAWM G″, tumor/NAWM |G*|, convexity, and tumor G″ emerged as the strongest candidate features, indicating that RN is mechanically harder and more dissipative than recurrent metastasis. Signal strength was high (Cliff’s δ up to 1.00) but should be interpreted cautiously given sample size. Exploratory analyses further suggest that instability mapping captures biologically relevant interface behavior. These findings support a mechanics-based RN-versus-recurrence framework and justify prespecified, preregistered external validation.
Open AccessDifferentiating radiation necrosis from recurrent brain metastases using magnetic resonance elastography
Background: Conventional MRI cannot reliably distinguish radiation necrosis (RN) from recurrent metastasis after cranial radiotherapy, as both can show similar enhancement despite different biology. We tested whether these entities are mechanically non-equivalent in vivo and separable by MRE-derived viscoelastic metrics and perilesional interface-instability features. Methods: In a prospective, histopathology-anchored cohort, 11 post-radiotherapy enhancing lesions were classified as RN (n=3) or recurrent/progressive tumor (n=8). MRE was acquired at 3.0 T with single-frequency 60-Hz excitation to derive storage modulus (G′), loss modulus (G″), and complex shear modulus magnitude (|G*|). Co-primary endpoints were median tumor G′ and |G*|, each tested one-sided (RN > tumor) with Holm correction across the two co-primary tests. Median tumor G″ was tested two-sided. A prespecified secondary 6-endpoint family (absolute and tumor/NAWM-normalized G′, G″, and |G*|) was analyzed with Benjamini–Hochberg FDR control. Exploratory instability mapping in a 0–6 mm peritumoral shell generated interface-topology metrics, including convexity. Results: Absolute tumor-core medians were higher in RN than tumor for |G*| (1.79 vs 1.32 kPa; Cliff’s δ=0.67; q=0.10), G′ (1.62 vs 1.09 kPa; δ=0.50; q=0.14), and G″ (0.81 vs 0.46 kPa; δ=0.75; q=0.10). NAWM normalization improved separation: tumor/NAWM |G*| (2.26 vs 1.41; δ=0.92; q=0.04) and tumor/NAWM G″ (2.67 vs 0.87; δ=1.00; q=0.04) were FDR-significant. Convexity also differentiated RN from tumor (0.49 vs 0.36; δ=1.00; MWU p=0.01). Conclusions: Tumor/NAWM G″, tumor/NAWM |G*|, convexity, and tumor G″ emerged as the strongest candidate features, indicating that RN is mechanically harder and more dissipative than recurrent metastasis. Signal strength was high (Cliff’s δ up to 1.00) but should be interpreted cautiously given sample size. Exploratory analyses further suggest that instability mapping captures biologically relevant interface behavior. These findings support a mechanics-based RN-versus-recurrence framework and justify prespecified, preregistered external validation.
- Open Access
- 27 November 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 174, 107282
Viscoelastic phenotyping of meningiomas reveals biomechanical classes and intratumoral heterogeneity
- 27 November 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 174, 107282
Open AccessViscoelastic phenotyping of meningiomas reveals biomechanical classes and intratumoral heterogeneity
- Open Access
Mechanical Instability as a Signature of Viscoelastic Decoupling at the Tumor–Brain Interface
Brain tumors alter the viscoelastic equilibrium of surrounding tissue, but how these changes shape the mechanics of tumor–brain coupling remains unclear. This study introduces mechanical instability mapping, a voxelwise measure of imbalance between elastic storage and viscous dissipation derived from magnetic resonance elastography (MRE). Twenty-eight patients (15 meningiomas, 13 glioblastomas) were analyzed using standardized 3 T MRE and tumor segmentation. Quantitative descriptors of instability topology—including skeleton length and branch-point densities, and radial persistence (radial-AUC)—were compared across WHO I, WHO II, and glioblastoma groups. Glioblastomas showed diffuse, branched instability fields with significantly higher skeleton and branch-point densities and lower radial-AUC compared with WHO I meningiomas, which exhibited compact, radially coherent patterns; WHO II meningiomas were intermediate. Group-average probability maps confirmed a transition from coherent to fragmented instability with increasing malignancy. These findings demonstrate that peritumoral mechanical topology reflects the degree of viscoelastic coupling at the tumor–brain interface. Instability mapping thereby extends conventional stiffness-based MRE metrics, offering a quantitative framework for assessing interface integrity and heterogeneity that may aid in elasticity-guided treatment strategies and biomechanical phenotyping of brain tumors. Statement of significance: Intracranial tumors can disrupt the mechanical equilibrium of the brain, yet how these changes govern tissue deformation, invasion, and surgical behavior remains unclear. Here we introduce mechanical instability mapping —a framework that quantifies the spatial organization of viscoelastic imbalance around tumors using magnetic resonance elastography. Distinct topological patterns of instability differentiate benign from malignant lesions: meningiomas preserve coherent elastic coupling, whereas glioblastomas display fragmented, dissipative fields indicative of invasive, mechanically decoupled growth. These findings identify a new biomechanical signature of tumor–brain interaction and establish instability topology as a quantitative link between imaging, histopathology, and operative mechanics, with potential applications in elasticity-guided neurosurgery, biomechanical phenotyping, and MR-based histopathology.
Open AccessMechanical Instability as a Signature of Viscoelastic Decoupling at the Tumor–Brain Interface
Brain tumors alter the viscoelastic equilibrium of surrounding tissue, but how these changes shape the mechanics of tumor–brain coupling remains unclear. This study introduces mechanical instability mapping, a voxelwise measure of imbalance between elastic storage and viscous dissipation derived from magnetic resonance elastography (MRE). Twenty-eight patients (15 meningiomas, 13 glioblastomas) were analyzed using standardized 3 T MRE and tumor segmentation. Quantitative descriptors of instability topology—including skeleton length and branch-point densities, and radial persistence (radial-AUC)—were compared across WHO I, WHO II, and glioblastoma groups. Glioblastomas showed diffuse, branched instability fields with significantly higher skeleton and branch-point densities and lower radial-AUC compared with WHO I meningiomas, which exhibited compact, radially coherent patterns; WHO II meningiomas were intermediate. Group-average probability maps confirmed a transition from coherent to fragmented instability with increasing malignancy. These findings demonstrate that peritumoral mechanical topology reflects the degree of viscoelastic coupling at the tumor–brain interface. Instability mapping thereby extends conventional stiffness-based MRE metrics, offering a quantitative framework for assessing interface integrity and heterogeneity that may aid in elasticity-guided treatment strategies and biomechanical phenotyping of brain tumors. Statement of significance: Intracranial tumors can disrupt the mechanical equilibrium of the brain, yet how these changes govern tissue deformation, invasion, and surgical behavior remains unclear. Here we introduce mechanical instability mapping —a framework that quantifies the spatial organization of viscoelastic imbalance around tumors using magnetic resonance elastography. Distinct topological patterns of instability differentiate benign from malignant lesions: meningiomas preserve coherent elastic coupling, whereas glioblastomas display fragmented, dissipative fields indicative of invasive, mechanically decoupled growth. These findings identify a new biomechanical signature of tumor–brain interaction and establish instability topology as a quantitative link between imaging, histopathology, and operative mechanics, with potential applications in elasticity-guided neurosurgery, biomechanical phenotyping, and MR-based histopathology.
- 8 October 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (3) , 774-782
Evaluating Measurement Stability in Glioblastomas Using Magnetic Resonance Elastography: Repeatability and Interobserver Agreement
Background: Magnetic resonance elastography (MRE) has demonstrated potential in characterizing intracranial tumors, including glioblastoma. The influence of pathology on measurement consistency and interobserver agreement needs evaluation to promote MRE implementation as a quantitative biomarker. Purpose: To assess repeatability and interobserver agreement of absolute and normalized magnitude of the complex shear modulus (| G *|), storage modulus ( G ′), and loss modulus ( G ″) in glioblastoma. Study Type: Prospective. Population: Thirteen adults (5 male, 8 female, mean age 66.23 years) with histopathologically confirmed glioblastoma. Field Strength/Sequence: 3 T MRI, modified single‐shot spin‐echo echo‐planar imaging. Assessment: Two same‐session MRE acquisitions were performed with patient repositioning. The solid tumor component was independently segmented by 2 observers on contrast‐enhanced T1‐weighted images co‐registered to MRE maps. Statistical Tests: Repeatability was assessed using the repeatability coefficient, coefficient of variation, and Bland–Altman plots, and interobserver agreement by the intraclass correlation coefficient. The Wilcoxon signed‐rank test compared parameters and coefficients of variation between tumor‐normal‐appearing white matter and absolute and normalized measurements. Significance was set at 0.05. Results: Tumor | G *| and G ′ showed repeatability coefficients of 0.07–0.08 kPa and 0.05 kPa, compared with 0.13 kPa (| G *|) and 0.15–0.16 kPa ( G ′) for normalized measurements. Coefficients of variation in tumor regions were 1.42% ± 1.12%–1.60% ± 1.41% for | G *| and 1.19% ± 0.96%–2.08% ± 2.22% for G ′, significantly lower than normalized values (4.82% ± 4.49%–4.21% ± 4.27% for | G *|; 5.12% ± 5.04%–5.45% ± 4.53% for G ′). Tumor | G *| and G ′ showed excellent interobserver agreement (intraclass correlation coefficients 0.97 and 0.95). Tumor G ″ demonstrated higher variability than | G *| and G ′ (coefficients of variation 8.58% ± 7.69%–7.51% ± 6.73%), with no significant difference between absolute and normalized measurements ( p = 0.14). Data Conclusion: Tumor | G *| and G ′ are the most repeatable metrics in glioblastoma. Normalization reduces measurement repeatability due to normal‐appearing white matter variability. The small sample size ( n = 13) limits generalizability. Evidence Level: 2. Technical Efficacy: Stage 2.
- 8 October 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (3) , 774-782
Evaluating Measurement Stability in Glioblastomas Using Magnetic Resonance Elastography: Repeatability and Interobserver Agreement
Background: Magnetic resonance elastography (MRE) has demonstrated potential in characterizing intracranial tumors, including glioblastoma. The influence of pathology on measurement consistency and interobserver agreement needs evaluation to promote MRE implementation as a quantitative biomarker. Purpose: To assess repeatability and interobserver agreement of absolute and normalized magnitude of the complex shear modulus (| G *|), storage modulus ( G ′), and loss modulus ( G ″) in glioblastoma. Study Type: Prospective. Population: Thirteen adults (5 male, 8 female, mean age 66.23 years) with histopathologically confirmed glioblastoma. Field Strength/Sequence: 3 T MRI, modified single‐shot spin‐echo echo‐planar imaging. Assessment: Two same‐session MRE acquisitions were performed with patient repositioning. The solid tumor component was independently segmented by 2 observers on contrast‐enhanced T1‐weighted images co‐registered to MRE maps. Statistical Tests: Repeatability was assessed using the repeatability coefficient, coefficient of variation, and Bland–Altman plots, and interobserver agreement by the intraclass correlation coefficient. The Wilcoxon signed‐rank test compared parameters and coefficients of variation between tumor‐normal‐appearing white matter and absolute and normalized measurements. Significance was set at 0.05. Results: Tumor | G *| and G ′ showed repeatability coefficients of 0.07–0.08 kPa and 0.05 kPa, compared with 0.13 kPa (| G *|) and 0.15–0.16 kPa ( G ′) for normalized measurements. Coefficients of variation in tumor regions were 1.42% ± 1.12%–1.60% ± 1.41% for | G *| and 1.19% ± 0.96%–2.08% ± 2.22% for G ′, significantly lower than normalized values (4.82% ± 4.49%–4.21% ± 4.27% for | G *|; 5.12% ± 5.04%–5.45% ± 4.53% for G ′). Tumor | G *| and G ′ showed excellent interobserver agreement (intraclass correlation coefficients 0.97 and 0.95). Tumor G ″ demonstrated higher variability than | G *| and G ′ (coefficients of variation 8.58% ± 7.69%–7.51% ± 6.73%), with no significant difference between absolute and normalized measurements ( p = 0.14). Data Conclusion: Tumor | G *| and G ′ are the most repeatable metrics in glioblastoma. Normalization reduces measurement repeatability due to normal‐appearing white matter variability. The small sample size ( n = 13) limits generalizability. Evidence Level: 2. Technical Efficacy: Stage 2.
- Open Access
- 15 May 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (4) , 1047-1058
Repeatability of Magnetic Resonance Elastography‐Derived Mechanical Parameters in Intracranial Meningiomas
Background: Magnetic resonance elastography (MRE) quantifies tissue viscoelasticity, offering insights into intracranial meningiomas. MRE‐derived parameters, including the storage modulus (G') and the magnitude of the complex modulus (|G*|), may aid neurosurgical planning, but their repeatability remains unexplored in brain tumors.Purpose/Hypothesis: To evaluate the repeatability of G' and |G*| in meningiomas, the influence of tumor volume and spatial location on variability, and ranking stability across paired elastograms.Study Type: Prospective.Population/Subjects: Seventeen paired MRE scans from 16 patients with meningiomas (mean age 64 ± 12 years, 10 females) scheduled for resection.Field Strength/Sequence: MRE was performed on a 3 T system using a single‐shot spin‐echo echo‐planar imaging (SE‐EPI) sequence.Assessment: Tumors were segmented on contrast‐enhanced T1‐weighted images; distance and volume metrics were extracted. Regions of interest were applied to G' and |G*| elastograms. Repeatability was evaluated using the coefficient of variation (CV%). Ranking stability was assessed by comparing median G' or |G*| values.Statistical Tests: The difference in CV% was assessed using the Wilcoxon signed rank test. Linear regression assessed the effect of tumor volume and distance from the external occipital protuberance (EOP) on CV%. The Wilcoxon signed‐rank test evaluated ranking stability and scan‐rescan CV%. Statistical significance was defined as p < 0.05.Results: The difference in CV% G' (14.89 ± 12.32) and CV% |G*| (13.88 ± 12.60) was not significant (p = 0.61). Tumor volume inversely correlated with CV% (G': β = −0.75 |G*|: β = −0.59). Tumor‐EOP distance had no significant effect (G': p = 0.58, |G*|: p = 0.23). Rankings remained stable (G': p = 0.82, |G*|: p = 0.71).Data Conclusion: MRE‐derived parameters are repeatable in intracranial meningiomas, with G' and |G*| being equally stable. Larger tumors yielded more consistent estimates. Preserved ranking stability supports the use of MRE in preoperative planning.Evidence Level: 2.Technical Efficacy: Stage 2.
- 15 May 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (4) , 1047-1058
Open AccessRepeatability of Magnetic Resonance Elastography‐Derived Mechanical Parameters in Intracranial Meningiomas
Background: Magnetic resonance elastography (MRE) quantifies tissue viscoelasticity, offering insights into intracranial meningiomas. MRE‐derived parameters, including the storage modulus (G') and the magnitude of the complex modulus (|G*|), may aid neurosurgical planning, but their repeatability remains unexplored in brain tumors.Purpose/Hypothesis: To evaluate the repeatability of G' and |G*| in meningiomas, the influence of tumor volume and spatial location on variability, and ranking stability across paired elastograms.Study Type: Prospective.Population/Subjects: Seventeen paired MRE scans from 16 patients with meningiomas (mean age 64 ± 12 years, 10 females) scheduled for resection.Field Strength/Sequence: MRE was performed on a 3 T system using a single‐shot spin‐echo echo‐planar imaging (SE‐EPI) sequence.Assessment: Tumors were segmented on contrast‐enhanced T1‐weighted images; distance and volume metrics were extracted. Regions of interest were applied to G' and |G*| elastograms. Repeatability was evaluated using the coefficient of variation (CV%). Ranking stability was assessed by comparing median G' or |G*| values.Statistical Tests: The difference in CV% was assessed using the Wilcoxon signed rank test. Linear regression assessed the effect of tumor volume and distance from the external occipital protuberance (EOP) on CV%. The Wilcoxon signed‐rank test evaluated ranking stability and scan‐rescan CV%. Statistical significance was defined as p < 0.05.Results: The difference in CV% G' (14.89 ± 12.32) and CV% |G*| (13.88 ± 12.60) was not significant (p = 0.61). Tumor volume inversely correlated with CV% (G': β = −0.75 |G*|: β = −0.59). Tumor‐EOP distance had no significant effect (G': p = 0.58, |G*|: p = 0.23). Rankings remained stable (G': p = 0.82, |G*|: p = 0.71).Data Conclusion: MRE‐derived parameters are repeatable in intracranial meningiomas, with G' and |G*| being equally stable. Larger tumors yielded more consistent estimates. Preserved ranking stability supports the use of MRE in preoperative planning.Evidence Level: 2.Technical Efficacy: Stage 2.
- Open Access
- 22 January 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 524-530
Repeatability of diffusion-based stiffness prediction – A healthy volunteer study
- 22 January 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 524-530
Open AccessRepeatability of diffusion-based stiffness prediction – A healthy volunteer study
- Open Access
- 1 February 2022
- Published by Elsevier in Radiography
- Vol. 28 (1) , 95-101
Amide proton transfer-weighted MRI in the clinical setting – correlation with dynamic susceptibility contrast perfusion in the post-treatment imaging of adult glioma patients at 3T
- 1 February 2022
- Published by Elsevier in Radiography
- Vol. 28 (1) , 95-101
Open AccessAmide proton transfer-weighted MRI in the clinical setting – correlation with dynamic susceptibility contrast perfusion in the post-treatment imaging of adult glioma patients at 3T