BLBilly L. Luu

Billy L. Luu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Billy L. Luu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Abdominal functional electrical stimulation and binder to reduce orthostatic hypotension in individuals with a subacute spinal cord injury

    by Chiettha Prajnadewie, Lynn Blecher, Keith MD McNaughton, Claire L. Boswell-Ruys, Billy L. Luu, Harrison T. Finn, Elizabeth A. Bye, Bonsan B. Lee, Jane E. Butler, Anne E. Palermo, et al.

    Study design: Repeated measures comparative study. Objectives: Compare acute effects of 4 treatment conditions: (i) abdominal binder (Binder), (ii) abdominal functional electrical stimulation (AFES), (iii) AFES and binder (AFES-Binder), and (iv) no intervention (Control), on signs of orthostatic hypotension (OH) and blood pressure (BP) maintenance in individuals with acute and subacute spinal cord injury (SCI). Setting: Spinal injury inpatient ward. Methods: Eleven participants with SCI (C3-T5) with at least one sign or symptom of OH underwent a passive sit-up test on 4 days with the 4 treatment conditions. Non-invasive continuous recordings of systolic BP, diastolic BP and calculated mean arterial pressure (MAP) were measured during 4 periods: (1) supine without treatment (5 min); (2) supine with treatment (5 min); (3) upright with treatment (up to 15 min); and (4) supine post-treatment (10 min). Results: Largest drops in BP still resulted in OH in all conditions ( p < 0.001), with the largest instantaneous change in MAP in the Binder condition (−41 mmHg [95% CI, −47 to −34]). AFES-Binder condition maintained mean upright MAP relative to supine (−1 mmHg [95% CI, −5 to 2], p = 0.291). Mean upright MAP decreased in all other conditions [Control: (−4 mmHg [95% CI, −7 to −1], p = 0.002); Binder: (−7 mmHg [−10 to −4], p < 0.001); AFES: (−6 mmHg [95% CI, −9 to −2], p < 0.001)]. Mean upright MAP was highest in the AFES-Binder condition. Conclusions: No single treatment condition prevented OH completely. While AFES with abdominal binder does not eliminate OH, it shows potential to mitigate BP instability during postural transitions in acute and subacute SCI.

  • Open Access

    Cardiovascular effects of transcutaneous spinal stimulation in persons living with and without spinal cord injury

    by Peter Sturgess, Terry Trinh, Billy L. Luu, Chiettha Prajnadewie, Simon C. Gandevia, Jane E. Butler, Martin E. Héroux

    Study design: Case-control series. Objectives: To investigate the cardiovascular effects of transcutaneous spinal stimulation (TSS) during orthostatic challenge in persons with and without spinal cord injury (SCI). Setting: Laboratory. Methods: Eleven persons with cervical SCI and ten persons without SCI participated in this study. Baseline systolic blood pressure (SBP) and heart rate (HR) were measured during an orthostatic challenge (10 min horizontal, 10 min upright). This was repeated with TSS (cathode: T7/T8 or T11/T12) applied when upright, and subsequently for 2 min when horizontal. SBP and HR were compared across groups and experimental conditions with linear mixed models. Results: When upright without TSS, SBP increased in the non-SCI group but decreased in the SCI group (mean difference −19.8 mmHg [95% CI, −33.6 to −6.0]). When upright with TSS, SBP increased in the SCI group, similar to non-SCI group (T7/T8: −6.6 mmHg [−20.4 to 7.3], T11/T12: 2.5 mmHg [−11.3 to 16.3]; non-SCI – SCI). In participants with SCI and orthostatic hypotension (OH), TSS at T11/T12 limited the orthostatic drop by 25.8 mmHg [5.0 to 46.6]. When horizontal, TSS increased SBP in the SCI group (T7/T8: 24.7 mmHg [16.8 to 32.6], T11/T12: 27.2 mmHg [19.3 to 35.1]). Conclusion: Spinal stimulation at T11/T12 improved OH in persons with SCI. However, it also increases SBP when applied in a horizontal position, a caution for its clinical use. Future studies in people with SCI should explore the potential mechanisms responsible for these TSS-induced SBP effects.

  • Open Access

    Spinal root magnetic stimulation: evaluating the limitations of a less invasive method to assess voluntary activation of the respiratory muscles

    by Chiettha Prajnadewie, Billy L. Luu, Harrison T. Finn, Anandit J. Mathew, Simon C. Gandevia, Anna L. Hudson, Jane E. Butler

    Magnetic stimulation of the cervical spinal roots cannot be used to assess voluntary activation of the diaphragm reliably during inspiratory efforts. However, magnetic stimulation of the thoracic spinal roots could be used to assess abdominal muscle voluntary activation during expiratory efforts but, importantly, required estimation of the twitch response at rest. This novel, less invasive method may be used to assess expiratory muscle activation, but requires testing across a range of contraction intensities.

  • Open Access

    Temporal summation in human peripheral axons when stimulated transcutaneously with a 10‐kHz waveform

    by Billy L. Luu, Harrison T. Finn, Terry Trinh, Simon C. Gandevia, Martin E. Héroux, Jane E. Butler

    Transcutaneous spinal cord stimulation, as used for rehabilitation of impaired motor function after spinal cord injury, often involves a 10‐kHz waveform modulated to produce repetitive bursts of stimulation. Kilohertz‐frequency waveforms may facilitate the summation of subthreshold depolarisations, but the optimal burst duration for nerve stimulation has not been systematically investigated. In 11 adults, the ulnar nerve was stimulated transcutaneously with a 10‐kHz waveform that contained 1, 2, 4, 6, 8 or 10 pulses, in random order. Compound muscle action potentials (CMAPs) and sensory nerve action potentials (SNAPs) were measured from motor threshold up to the maximal CMAP ( M max ). The efficacy of each waveform was determined at M max as CMAP amplitude divided by total phase charge. For CMAPs and SNAPs, increasing the number of pulses shifted the stimulus–response curves to the left for current and to the right for total charge. Accordingly, an increase in the number of pulses decreased the current but increased the total charge at sensory and motor thresholds and M max . Efficacy decreased as the number of pulses increased. Onset latencies were delayed for waveforms with six or more pulses compared to a single pulse. These findings provide evidence of the summation of subthreshold depolarisations in sensory and motor axons in humans. However, the optimal number of pulses for summation remains unclear due to the opposing changes in current and total charge. It is clear, though, that more than six pulses is suboptimal, as there were no further decreases in threshold current while total charge continued to increase.


  • Open Access

    Pain tolerance and the thresholds of human sensory and motor axons to single and repetitive bursts of kilohertz‐frequency stimulation

    by Billy L. Luu, Terry Trinh, Harrison T. Finn, Felix P. Aplin, Simon C. Gandevia, Martin E. Héroux, Jane E. Butler

    Transcutaneous electrical stimulation with repetitive bursts of a kilohertz carrier frequency is thought to be less painful than conventional pulsed currents by reducing the sensitivity of pain receptors. However, no purported benefit has been shown unequivocally. We compared the effects of carrier‐frequency stimulation and conventional stimulation on pain tolerance and the thresholds for sensory and motor axons in twelve participants. The ulnar nerve was stimulated transcutaneously with a conventional single pulse and 5 and 10 kHz carrier‐frequency waveforms that had 5 and 10 pulses, respectively, when delivered in bursts of ∼1 ms duration. Phase durations were adjusted across waveform types to match the total charge for a given current amplitude. Single bursts of stimulation were delivered from 1 mA up until no longer tolerable. This was repeated with repetitive bursts of stimulation at 20 Hz for 1 s. Participants tolerated higher current amplitudes with both carrier‐frequency waveforms than conventional stimulation, with repetitive bursts more painful than single bursts. However, compared to conventional stimulation, carrier‐frequency waveforms required more current to produce sensory and motor‐threshold responses and to obtain a maximal motor response (Mmax). When the current at pain tolerance was normalised to the current at Mmax, participants tolerated lower stimulus intensities with carrier‐frequency waveforms than conventional stimulation. These findings indicate that there is little to no benefit in using carrier‐frequency waveforms to minimise the discomfort from electrical stimulation as the increase in stimulus intensity at pain tolerance is more than offset by reduced effectiveness in the activation of sensory and motor axons. image Key points: Transcutaneous electrical stimulation with repetitive bursts of a kilohertz carrier‐frequency waveform is thought to be less painful than conventional pulsed currents. For ulnar nerve stimulation, when stimulus waveforms were matched for total phase charge, participants tolerated higher current amplitudes with carrier‐frequency stimulation than conventional stimulation. However, compared to conventional stimulation, carrier‐frequency waveforms required more current to produce a threshold response in both sensory and motor axons and to produce a maximal motor response (Mmax). When current at pain tolerance was normalised to current at Mmax, participants tolerated lower stimulus intensities with carrier‐frequency waveforms than conventional stimulation. Carrier‐frequency waveforms provide little to no benefit in minimising the discomfort from transcutaneous electrical stimulation as the increase in stimulus intensity at pain tolerance is more than offset by reduced effectiveness in activating sensory and motor axons.


  • Graded onset of parasternal intercostal inspiratory activity detected with surface electromyography in healthy young females and males

    by Anna L. Hudson, Billy L. Luu, Simon C. Gandevia, Jane E. Butler

    We demonstrated that surface EMG is a valid method to measure graded inspiratory EMG in the parasternal intercostal muscles in healthy young male and female participants during quiet breathing and loaded breathing. Across the 1st-to-5th interspaces, there was more homogenous activation in women and more graded activity in men across parasternal intercostal muscles during breathing. By recording surface EMG from both male and female participants, we have revealed sex differences in inspiratory activity across intercostal muscles.


  • Open Access

    Effect of respiratory muscle training on load sensations in people with chronic tetraplegia: a secondary analysis of a randomised controlled trial

    by Billy L. Luu, R. H. Chaminda Lewis, Rachel A. McBain, Simon C. Gandevia, Claire L. Boswell-Ruys, Jane E. Butler

    Study design: Secondary analysis of a randomised controlled trial. Objectives: Our primary study showed that increasing inspiratory muscle strength with training in people with chronic (>1 year) tetraplegia corresponded with reduced sensations of breathlessness when inspiration was loaded. This study investigated whether respiratory muscle training also affected the respiratory sensations for load detection and magnitude perception. Setting: Independent research institute in Sydney, Australia. Methods: Thirty-two adults with chronic tetraplegia participated in a 6-week, supervised training protocol. The active group trained the inspiratory muscles through progressive threshold loading. The sham group performed the same protocol with a fixed threshold load (3.6 cmH2O). Primary measures were load detection threshold and perceived magnitudes of six suprathreshold loads reported using the modified Borg scale. Results: Maximal inspiratory pressure (Pimax) increased by 32% (95% CI, 18–45) in the active group with no change in the sham group (p = 0.51). The training intervention did not affect detection thresholds in the active (p = 0.24) or sham (p = 0.77) group, with similar overall decreases in Borg rating of 0.83 (95% CI, 0.49–1.17) in active and 0.72 (95% CI, 0.32–1.12) in sham group. Increased inspiratory muscle strength reduced slope magnitude between Borg rating and peak inspiratory pressure (p = 0.003), but not when pressure was divided by Pimax to reflect contraction intensity (p = 0.92). Conclusions: Training reduces the sensitivity of load sensations for a given change in pressure but not for a given change in contraction intensity.


  • The detection and sensory perception of inspiratory resistive loads in people with chronic tetraplegia

    by Billy L. Luu, R. H Chaminda Lewis, Simon C. Gandevia, Claire L. Boswell-Ruys, Jane E. Butler

    This study investigated sensations of breathing following tetraplegia. Fifteen people with chronic tetraplegia and fifteen healthy able-bodied controls matched for age, sex, height, and weight participated. Sensations of breathing were quantified by determining the threshold for detecting an added resistance during inspiration. In a separate task, the perceived magnitudes of six suprathreshold resistive loads were determined with a modified Borg scale. The detection threshold of 0.34 cmH2O/l/s (standard deviation (SD) 0.14) in the tetraplegia group was higher than the 0.23 cmH2O/l/s (SD 0.10) threshold for able-bodied controls (p = 0.004). Both participant groups perceived larger loads to be more effortful, with Borg effort rating increasing linearly with the peak inspiratory pressure generated at each load. The relationship between Borg effort rating and peak inspiratory pressure was steeper in participants with tetraplegia than able-bodied controls (p = 0.001), but there was no difference when pressure was divided by maximal inspiratory pressure (p = 0.95). Despite a higher detection threshold, the findings suggest that the perceived magnitude of a suprathreshold inspiratory load is not impaired in chronic tetraplegia, and that load magnitude perception is related to the maximal, and not absolute, inspiratory muscle force.


  • Tongue acceleration in humans evoked with intramuscular electrical stimulation of genioglossus

    by Billy L. Luu, Lee D. Walsh, Patrick P. Hübner, Danny J. Eckert, Lynne E. Bilston, Simon C. Gandevia, Jane E. Butler


  • Open Access

    Intergenerational Practice in the Community—What Does the Community Think?

    by Gail Kenning, Nicole Ee, Ying Xu, Billy L. Luu, Stephanie A. Ward, Micah B. Goldwater, Ebony Lewis, Katrina Radford, Kaarin J. Anstey, Nicola T. Lautenschlager, et al.

    The many changes that occur in the lives of older people put them at an increased risk of being socially isolated and lonely. Intergenerational programs for older adults and young children can potentially address this shortfall, because of the perceived benefit from generations interacting. This study explores whether there is an appetite in the community for intergenerational programs for community dwelling older adults. An online survey was distributed via social media, research team networks, and snowballing recruitment with access provided via QR code or hyperlink. Semi-structured interviews were undertaken with potential participants of a pilot intergenerational program planned for the Eastern Suburbs of Sydney, Australia in 2020. The interviews were thematically analyzed. Over 250 people completed the survey, and 21 interviews took place with older adults (10) and parents of young children (11). The data showed that participants were all in favor of intergenerational programs, but there were different perceptions about who benefits most and how. The study highlighted considerations to be addressed in the development of effective and sustainable intergenerational programs. For example, accessing people in the community who are most socially isolated and lonely was identified as a primary challenge. More evidence-based research is needed to support involvement of different cohorts, such as those who are frail, or living with physical or cognitive limitations.