Waranon Munkong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Waranon Munkong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Panuwat Pattum
Department of Radiology, Faculty of Medicine Khon Kaen University Khon Kaen Thailand
2 shared publications - Thawatchai Prabsattroo
Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
2 shared publications - Woranan Kirisattayakul
Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
2 shared publications - Kanokporn Boonsirichai
Nuclear Technology Research and Development Center, Thailand Institute of Nuclear Technology (Public Organization), Nakhon Nayok 26120, Thailand
1 shared publication - Lamai Maikaeo
Thailand Institute of Nuclear Technology (Public Organization) Nakhon Nayok Thailand
1 shared publication - Panatsada Awikunprasert
Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
1 shared publication
Latest Publications
- 2 May 2025
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 58 (2) , 148-160
Radiation safety assessment of patient and staff during intracranial aneurysm treatment: A phantom study
Background: Endovascular treatment using coiling embolization for intracranial aneurysms is common in interventional neuroradiology (INR). However, it is associated with high radiation exposure to both patients and medical staff. The assessment and management of radiation risk have been a concern. Objective: To evaluate patient and scatter radiation doses at INR staff working position during the coiling embolization procedure in a phantom study. Materials and methods: An anthropometric phantom from head to pelvis was placed on an angiographic table. To determine the phantom’s entrance skin dose (ESD), 19 NanoDot optically stimulated luminescence dosimeters (OSLDs) were placed on the surface of the head phantom. Moreover, 6 NanoDot OSLDs were also placed on the surface of the phantom at 3 critical organs (eyes, thyroid, ovaries). To determine the scatter radiation dose at staff working position, polyvinyl chloride pipes (150 cm height) were placed at the position of all staff, including interventional radiologist (IR), radiology resident (RR), scrubbed nurse (SN), radiologic technologist (RT), circulating nurse (CN), and nurse anesthetists (AN). The InLight® OSLDs were placed on each PVC pipe at 50, 100, and 150 cm height from the floor level. Coiling embolization was simulated following the standard procedure using a bi-plane digital subtraction angiography unit with standard radiation protective equipment. The patient doses from the radiation dose structured report (RDSR) were also recorded. Results: The highest ESDs were observed in the occipital part (1,631.56±36.97 mGy). These ESD peaks were also observed within the safety limit and produced no skin reaction. The radiation dose at the left eye was observed to be the highest value among critical organs. The highest scatter radiation dose was observed at the position of IR at 100 cm level. Among CN, AN, and RT positions, the highest dose was recorded at the RT position at the level of 150 cm. The RDSR showed that most of the patient radiation dose was received from the 2-dimension angiography. Conclusion: The distribution of radiation dose varied across different staff positions. As the key person conducting the coiling embolization procedure, the IR position received the highest radiation dose. Thus, close monitoring and development of additional radiation protection methods for this position are essential. Although the radiation dose at the back of the head was elevated, it remained within safety limits. Nevertheless, the monitoring of potential radiation effects should not be neglected.
- 2 May 2025
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 58 (2) , 148-160
Radiation safety assessment of patient and staff during intracranial aneurysm treatment: A phantom study
Background: Endovascular treatment using coiling embolization for intracranial aneurysms is common in interventional neuroradiology (INR). However, it is associated with high radiation exposure to both patients and medical staff. The assessment and management of radiation risk have been a concern. Objective: To evaluate patient and scatter radiation doses at INR staff working position during the coiling embolization procedure in a phantom study. Materials and methods: An anthropometric phantom from head to pelvis was placed on an angiographic table. To determine the phantom’s entrance skin dose (ESD), 19 NanoDot optically stimulated luminescence dosimeters (OSLDs) were placed on the surface of the head phantom. Moreover, 6 NanoDot OSLDs were also placed on the surface of the phantom at 3 critical organs (eyes, thyroid, ovaries). To determine the scatter radiation dose at staff working position, polyvinyl chloride pipes (150 cm height) were placed at the position of all staff, including interventional radiologist (IR), radiology resident (RR), scrubbed nurse (SN), radiologic technologist (RT), circulating nurse (CN), and nurse anesthetists (AN). The InLight® OSLDs were placed on each PVC pipe at 50, 100, and 150 cm height from the floor level. Coiling embolization was simulated following the standard procedure using a bi-plane digital subtraction angiography unit with standard radiation protective equipment. The patient doses from the radiation dose structured report (RDSR) were also recorded. Results: The highest ESDs were observed in the occipital part (1,631.56±36.97 mGy). These ESD peaks were also observed within the safety limit and produced no skin reaction. The radiation dose at the left eye was observed to be the highest value among critical organs. The highest scatter radiation dose was observed at the position of IR at 100 cm level. Among CN, AN, and RT positions, the highest dose was recorded at the RT position at the level of 150 cm. The RDSR showed that most of the patient radiation dose was received from the 2-dimension angiography. Conclusion: The distribution of radiation dose varied across different staff positions. As the key person conducting the coiling embolization procedure, the IR position received the highest radiation dose. Thus, close monitoring and development of additional radiation protection methods for this position are essential. Although the radiation dose at the back of the head was elevated, it remained within safety limits. Nevertheless, the monitoring of potential radiation effects should not be neglected.
- 23 August 2021
- Published by Hindawi Limited in Journal of Food Biochemistry
- Vol. 46 (4) , e13909
Polygonum odoratum leaf extract attenuates oxidative stress and cell death of Raw 264.7 cells exposed to low dose ionizing radiation
This study aims to investigate the effect of Polygonum odoratum leaf extract (POE) on oxidative stress markers and cell death induced by low dose ionizing radiation (LDIR) in Raw 264.7 cells. The biological activities, chromatographic fingerprint, and cytotoxicity of POE were investigated. To determine the radioprotective effect of POE, Raw 264.7 cells were incubated with POE for 1 hr prior to 100 mGy x-irradiation. The cell viability, oxidative stress damage marker (malondialdehyde level; MDA), and endogenous antioxidant markers (superoxide dismutase: SOD, catalase: CAT, and glutathione peroxidase: GSH-Px) were also determined. The results showed that POE contained 8 essential substances and exhibited a potent antioxidant without any cytotoxicity. It was found that POE significantly decreased the MDA level and activated cell viability, SOD, CAT, and GSH-Px activities. The results from this study indicate that POE is a potent antioxidant, which can be developed as a radioprotector for diagnostic procedures. Practical applications Polygonum odoratum leaf extract (POE) is a potent antioxidant that attenuates oxidative stress and cell death induced by low dose ionizing radiation (LDIR). POE might protect against cell damage from LDIR, particularly in diagnostic radiology procedures. Therefore, the development of functional food containing POE might be beneficial for patients who plan to undergo the diagnostic radiology procedure. The functional food containing POE might prevent stochastic and deterministic effects for these patients.
- 23 August 2021
- Published by Hindawi Limited in Journal of Food Biochemistry
- Vol. 46 (4) , e13909
Polygonum odoratum leaf extract attenuates oxidative stress and cell death of Raw 264.7 cells exposed to low dose ionizing radiation
This study aims to investigate the effect of Polygonum odoratum leaf extract (POE) on oxidative stress markers and cell death induced by low dose ionizing radiation (LDIR) in Raw 264.7 cells. The biological activities, chromatographic fingerprint, and cytotoxicity of POE were investigated. To determine the radioprotective effect of POE, Raw 264.7 cells were incubated with POE for 1 hr prior to 100 mGy x-irradiation. The cell viability, oxidative stress damage marker (malondialdehyde level; MDA), and endogenous antioxidant markers (superoxide dismutase: SOD, catalase: CAT, and glutathione peroxidase: GSH-Px) were also determined. The results showed that POE contained 8 essential substances and exhibited a potent antioxidant without any cytotoxicity. It was found that POE significantly decreased the MDA level and activated cell viability, SOD, CAT, and GSH-Px activities. The results from this study indicate that POE is a potent antioxidant, which can be developed as a radioprotector for diagnostic procedures. Practical applications Polygonum odoratum leaf extract (POE) is a potent antioxidant that attenuates oxidative stress and cell death induced by low dose ionizing radiation (LDIR). POE might protect against cell damage from LDIR, particularly in diagnostic radiology procedures. Therefore, the development of functional food containing POE might be beneficial for patients who plan to undergo the diagnostic radiology procedure. The functional food containing POE might prevent stochastic and deterministic effects for these patients.