Klaus S. Lassen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Klaus S. Lassen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Reinar Grün
Plasma Technik Grün, Plateg, Industriestrasse 13, P.O. Box 210642, D‐57076 Siegen, Germany
3 shared publicationsBolette Nordby
Teknologisk Institut, Plastteknologi, Gregersensvej, DK-2630 Taastrup, Denmark
2 shared publications- Andrew Raymon Morton Bradbury
Specifica LLC, a Q2 Solutions Company, Santa Fe, USA
1 shared publication Jens E. Johansen
National Environmental Research Institute, Environmental Chemistry and Microbiology, Frederiksborgvej 399, 4000 Roskilde, Denmark
1 shared publicationJens F. Rehfeld
Department of Clinical Biochemistry (3014), Rigshospitalet, Copenhagen, Denmark
1 shared publicationNiels H. H. Heegaard
Department of Autoimmunology and Immunological Development, Statens Serum Institut, Copenhagen S, Denmark
1 shared publication
Latest Publications
- 20 June 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (12) , 2557-2564
Microscale characterization of the binding specificity and affinity of a monoclonal antisulfotyrosyl IgG antibody
Sulfation is a potentially important post-translational modification of proteins and has been demonstrated in a number of polypeptides, notably in gastrointestinal hormones. In contrast to phosphorylation, however, the investigation of sulfation patterns in tissues and on purified proteins has been complicated by the absence of specific immunoreagents (antibodies) for this modification as well as the chemical lability of the sulfate group. Here, we investigate the properties of a novel mAb against sulfated tyrosyl groups (anti-Tyr(SO3H) antibody) using CE and a panel of sulfated and nonsulfated peptides and proteins. The data show that the anti-Tyr(SO3H) antibody is completely specific for compounds containing sulfated tyrosyls. Affinity electrophoresis experiments allowed us to estimate dissociation constants for sulfated hirudin fragment (56–65), gastrin-17, and cholecystokinin octapeptide (CCK8) in the 1–3 μM range. The affinity of the antibody toward complement 4 protein that contains three sulfotyrosines was analyzed by surface plasmon resonance technology and modeled according to a bivalent-binding model which yielded a Kd1 of 20.1 μM for the monovalent complex. The same binding was studied by CE and found to be in the micromolar scale albeit with some uncertainty due to complex separation patterns. The work illustrates the amount of information on antibody–antigen interactions that may be obtained with microelectrophoretic methods consuming minute quantities of material. Furthermore the specificity of this antibody could be confirmed in one operation using an array of sulfated and nonsulfated compounds.
- 20 June 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (12) , 2557-2564
Microscale characterization of the binding specificity and affinity of a monoclonal antisulfotyrosyl IgG antibody
Sulfation is a potentially important post-translational modification of proteins and has been demonstrated in a number of polypeptides, notably in gastrointestinal hormones. In contrast to phosphorylation, however, the investigation of sulfation patterns in tissues and on purified proteins has been complicated by the absence of specific immunoreagents (antibodies) for this modification as well as the chemical lability of the sulfate group. Here, we investigate the properties of a novel mAb against sulfated tyrosyl groups (anti-Tyr(SO3H) antibody) using CE and a panel of sulfated and nonsulfated peptides and proteins. The data show that the anti-Tyr(SO3H) antibody is completely specific for compounds containing sulfated tyrosyls. Affinity electrophoresis experiments allowed us to estimate dissociation constants for sulfated hirudin fragment (56–65), gastrin-17, and cholecystokinin octapeptide (CCK8) in the 1–3 μM range. The affinity of the antibody toward complement 4 protein that contains three sulfotyrosines was analyzed by surface plasmon resonance technology and modeled according to a bivalent-binding model which yielded a Kd1 of 20.1 μM for the monovalent complex. The same binding was studied by CE and found to be in the micromolar scale albeit with some uncertainty due to complex separation patterns. The work illustrates the amount of information on antibody–antigen interactions that may be obtained with microelectrophoretic methods consuming minute quantities of material. Furthermore the specificity of this antibody could be confirmed in one operation using an array of sulfated and nonsulfated compounds.
- 16 December 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 78B (1) , 189-195
Comparison of two radio-frequency plasma sterilization processes using microspot evaluation of microbial inactivation
- 16 December 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 78B (1) , 189-195
Comparison of two radio-frequency plasma sterilization processes using microspot evaluation of microbial inactivation
- 11 March 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 74B (1) , 553-559
The dependence of the sporicidal effects on the power and pressure of RF‐generated plasma processes
The sporicidal effect of 20 different radio‐frequency plasma processes produced by combining five different gas mixtures [O2, Ar/H2 (50/50%), Ar/H2 (5/95%), O2/H2 (50/50%), O2/H2 (95/5%)] with four power/pressure settings were tested. Sporicidal effects of oxygen‐containing plasmas were dependent on power at low pressure settings but not at high pressure settings. In the absence of oxygen no power dependency was observed at either high or low pressure settings. Survivor curves obtained with the use of nonoxygen plasmas typically had a tailing tendency. Only a mixture‐optimized Ar/H2 (15/85%) plasma process was not encumbered by tailing, and produced a decimal reduction time (D value) below 2 min for Bacillus stearothermophilus spores. Scanning electron microscopy showed that a CF4/O2 plasma did more damage to the substrate than the 15/85% Ar/H2 plasma. The present results indicate that UV irradiation inactivation is swift and power and pressure independent. Additionally, it is produced at low energy. However, it is not complete. Inactivation through etching is highly power and pressure dependent; finally, inactivation by photodesorption is moderately power and pressure dependent. A sterilization process relying on this mechanism is very advantageous because it combines a highly sporicidal effect with low substrate damage. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater
- 11 March 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 74B (1) , 553-559
The dependence of the sporicidal effects on the power and pressure of RF‐generated plasma processes
The sporicidal effect of 20 different radio‐frequency plasma processes produced by combining five different gas mixtures [O2, Ar/H2 (50/50%), Ar/H2 (5/95%), O2/H2 (50/50%), O2/H2 (95/5%)] with four power/pressure settings were tested. Sporicidal effects of oxygen‐containing plasmas were dependent on power at low pressure settings but not at high pressure settings. In the absence of oxygen no power dependency was observed at either high or low pressure settings. Survivor curves obtained with the use of nonoxygen plasmas typically had a tailing tendency. Only a mixture‐optimized Ar/H2 (15/85%) plasma process was not encumbered by tailing, and produced a decimal reduction time (D value) below 2 min for Bacillus stearothermophilus spores. Scanning electron microscopy showed that a CF4/O2 plasma did more damage to the substrate than the 15/85% Ar/H2 plasma. The present results indicate that UV irradiation inactivation is swift and power and pressure independent. Additionally, it is produced at low energy. However, it is not complete. Inactivation through etching is highly power and pressure dependent; finally, inactivation by photodesorption is moderately power and pressure dependent. A sterilization process relying on this mechanism is very advantageous because it combines a highly sporicidal effect with low substrate damage. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater
- 15 May 2003
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 65 (2) , 239-244
Optimization of a RF-generated CF4/O2 gas plasma sterilization process
A sterilization process with the use of RF‐generated (13.56 MHz) CF4/O2 gas plasma was optimized in regards to power, flow rate, exposure time, and RF‐system type. The dependency of the sporicidal effect on the spore inoculum positioning in the chamber of the RF systems was also investigated. Dried Bacillus stearothermophilus ATCC 7953 endospores were used as test organisms. The treatments were evaluated on the basis of survival curves and corresponding D values. The only parameter found to affect the sterilization process was the power of the RF system. Higher power resulted in higher kill. Finally, when the samples were placed more than 3–8 cm away from a centrally placed electrode in System 2, the sporicidal effect was reduced. The results are discussed and compared to results from the present literature. The RF excitation source is evaluated to be more appropriate for sterilization processes than the MW source. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 65B: 239–244, 2003
- 15 May 2003
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 65 (2) , 239-244
Optimization of a RF-generated CF4/O2 gas plasma sterilization process
A sterilization process with the use of RF‐generated (13.56 MHz) CF4/O2 gas plasma was optimized in regards to power, flow rate, exposure time, and RF‐system type. The dependency of the sporicidal effect on the spore inoculum positioning in the chamber of the RF systems was also investigated. Dried Bacillus stearothermophilus ATCC 7953 endospores were used as test organisms. The treatments were evaluated on the basis of survival curves and corresponding D values. The only parameter found to affect the sterilization process was the power of the RF system. Higher power resulted in higher kill. Finally, when the samples were placed more than 3–8 cm away from a centrally placed electrode in System 2, the sporicidal effect was reduced. The results are discussed and compared to results from the present literature. The RF excitation source is evaluated to be more appropriate for sterilization processes than the MW source. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 65B: 239–244, 2003