Ziyue Zhang
Research Subjects
Ziyue Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Wen Fan
The First Affiliated Hospital of Nanjing Medical University
2 shared publications - Zexuan Ji
Nanjing University of Science and Technology
2 shared publications - Changzheng Chen
Eye Center, Renmin Hospital of Wuhan University, China
1 shared publication - Hongmei Zheng
Ophthalmology Center, Renmin Hospital of Wuhan University
1 shared publication - Qiang Chen
Nanjing University of Science and Technology
1 shared publication - Songtao Yuan
Department of Ophthalmology The First Affiliated Hospital with Nanjing Medical University Nanjing China
1 shared publication
Latest Publications
- Open Access
- 8 September 2021
- Published by Wiley in Journal of Diabetes Research
- Vol. 2021, 1-9
Automated Grading of Diabetic Retinopathy with Ultra-Widefield Fluorescein Angiography and Deep Learning
Purpose. The objective of this study was to establish diagnostic technology to automatically grade the severity of diabetic retinopathy (DR) according to the ischemic index and leakage index with ultra-widefield fluorescein angiography (UWFA) and the Early Treatment Diabetic Retinopathy Study (ETDRS) 7-standard field (7-SF). Methods. This is a cross-sectional study. UWFA samples from 280 diabetic patients and 119 normal patients were used to train and test an artificial intelligence model to differentiate PDR and NPDR based on the ischemic index and leakage index with UWFA. A panel of retinal specialists determined the ground truth for our data set before experimentation. A confusion matrix as a metric was used to measure the precision of our algorithm, and a simple linear regression function was implemented to explore the discrimination of indexes on the DR grades. In addition, the model was tested with simulated 7-SF. Results. The model classification of DR in the original UWFA images achieved 88.50 accuracy and 73.68 accuracy in the simulated 7-SF images. A simple linear regression function demonstrated that there is a significant relationship between the ischemic index and leakage index and the severity of DR. These two thresholds were set to classify the grade of DR, which achieved 76.8 accuracy. Conclusions. The optimization of the cycle generative adversarial network (CycleGAN) and convolutional neural network (CNN) model classifier achieved DR grading based on the ischemic index and leakage index with UWFA and simulated 7-SF and provided accurate inference results. The classification accuracy with UWFA is slightly higher than that of simulated 7-SF.
- 8 September 2021
- Published by Wiley in Journal of Diabetes Research
- Vol. 2021, 1-9
Open AccessAutomated Grading of Diabetic Retinopathy with Ultra-Widefield Fluorescein Angiography and Deep Learning
Purpose. The objective of this study was to establish diagnostic technology to automatically grade the severity of diabetic retinopathy (DR) according to the ischemic index and leakage index with ultra-widefield fluorescein angiography (UWFA) and the Early Treatment Diabetic Retinopathy Study (ETDRS) 7-standard field (7-SF). Methods. This is a cross-sectional study. UWFA samples from 280 diabetic patients and 119 normal patients were used to train and test an artificial intelligence model to differentiate PDR and NPDR based on the ischemic index and leakage index with UWFA. A panel of retinal specialists determined the ground truth for our data set before experimentation. A confusion matrix as a metric was used to measure the precision of our algorithm, and a simple linear regression function was implemented to explore the discrimination of indexes on the DR grades. In addition, the model was tested with simulated 7-SF. Results. The model classification of DR in the original UWFA images achieved 88.50 accuracy and 73.68 accuracy in the simulated 7-SF images. A simple linear regression function demonstrated that there is a significant relationship between the ischemic index and leakage index and the severity of DR. These two thresholds were set to classify the grade of DR, which achieved 76.8 accuracy. Conclusions. The optimization of the cycle generative adversarial network (CycleGAN) and convolutional neural network (CNN) model classifier achieved DR grading based on the ischemic index and leakage index with UWFA and simulated 7-SF and provided accurate inference results. The classification accuracy with UWFA is slightly higher than that of simulated 7-SF.
- 1 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (1) , 115-126
Joint Optimization of CycleGAN and CNN Classifier for Detection and Localization of Retinal Pathologies on Color Fundus Photographs
Retinal related diseases are the leading cause of vision loss, and severe retinal lesion causes irreversible damage to vision. Therefore, the automatic methods for retinal diseases detection based on medical images is essential for timely treatment. Considering that manual diagnosis and analysis of medical images require a large number of qualified experts, deep learning can effectively diagnosis and locate critical biomarkers. In this paper, we present a novel model by jointly optimize the cycle generative adversarial network (CycleGAN) and the convolutional neural network (CNN) to detect retinal diseases and localize lesion areas with limited training data. The CycleGAN with cycle consistency can generate more realistic and reliable images. The discriminator and the generator achieve a local optimal solution in an adversarial manner, and the generator and the classifier are in a cooperative manner to distinguish the domain of input images. A novel res-guided sampling block is proposed by combining learnable residual features and pixel-adaptive convolutions. A res-guided U-Net is constructed as the generator by substituting the traditional convolution with the res-guided sampling blocks. Our model achieve superior classification and localization performance on LAG, Ichallenge-PM and Ichallenge-AMD datasets. With clear localization for lesion areas, the competitive results reveal great potentials of the joint optimization network. The source code is available at https://github.com/jizexuan/JointOptmization.
- 1 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (1) , 115-126
Joint Optimization of CycleGAN and CNN Classifier for Detection and Localization of Retinal Pathologies on Color Fundus Photographs
Retinal related diseases are the leading cause of vision loss, and severe retinal lesion causes irreversible damage to vision. Therefore, the automatic methods for retinal diseases detection based on medical images is essential for timely treatment. Considering that manual diagnosis and analysis of medical images require a large number of qualified experts, deep learning can effectively diagnosis and locate critical biomarkers. In this paper, we present a novel model by jointly optimize the cycle generative adversarial network (CycleGAN) and the convolutional neural network (CNN) to detect retinal diseases and localize lesion areas with limited training data. The CycleGAN with cycle consistency can generate more realistic and reliable images. The discriminator and the generator achieve a local optimal solution in an adversarial manner, and the generator and the classifier are in a cooperative manner to distinguish the domain of input images. A novel res-guided sampling block is proposed by combining learnable residual features and pixel-adaptive convolutions. A res-guided U-Net is constructed as the generator by substituting the traditional convolution with the res-guided sampling blocks. Our model achieve superior classification and localization performance on LAG, Ichallenge-PM and Ichallenge-AMD datasets. With clear localization for lesion areas, the competitive results reveal great potentials of the joint optimization network. The source code is available at https://github.com/jizexuan/JointOptmization.