KWKevin K. F. Wong

Kevin K. F. Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kevin K. F. Wong has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Rong Yang

    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore

    3 shared publications
  • Dianfeng Zhao

    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore

    1 shared publication
  • Tso-Chien Pan

    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore

    1 shared publication
  • Y. Wang

    School of Civil and Structural Engineering, Nanyang Technological University, Singapore

    1 shared publication
  • Yi Wang

    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore

    1 shared publication
  • Yumei Wang

    School of Civil and Structural Engineering, Nanyang Technological University, Singapore

    1 shared publication

Latest Publications

  • Effectiveness of inelastic structural control based on elastic displacement and energy

    by Kevin K. F. Wong, Dianfeng Zhao

    A modified optimal linear control algorithm is proposed to demonstrate the effectiveness of the control system in reducing inelastic structural dynamic responses. This algorithm recognizes that permanent deformation in the structure due to structural yielding produces unnecessary additional feedback control forces in the control system, and thus this deformation should not be considered in the feedback control equation. Hence the unique feature of the currently proposed algorithm is that it is based on the elastic states only. Effectiveness of the proposed algorithm is then demonstrated by studying the control energy of the controlled structure. Numerical simulations using single-degree-of-freedom system responses show that there always exists a point where the control energy consumption is maximal, and this optimal point is dependent on the structural characteristics as well as the earthquake excitation. Hence a preliminary guideline is developed to estimate this optimal point. Finally, application of the proposed algorithm on a six-storey moment-resisting frame is presented to show the effectiveness of using optimal linear control on a multi-degree-of-freedom system from the control energy perspectives. Copyright © 2004 John Wiley & Sons, Ltd.


  • Predictive inelastic state control of modern structures during earthquakes

    by Rong Yang, Kevin K. F. Wong, Tso-Chien Pan

    The predictive inelastic state control (PISC) algorithm is proposed by incorporating an elastic‐based predictive state control algorithm with inelastic structural analysis. Force analogy method based on initial stiffness is used in the analysis to simplify the numerical computation. This proposed inelastic control algorithm compensates for the time delay that occurs in practical application of structural control by predicting the inelastic structural response over a period equal to the time delay, and substituting the predicted structural response in the expression of an ideal control force without considering time delays. A one‐storey moment‐resisting frame with different inelastic characteristics is analyzed using this algorithm. Numerically simulated results show that the proposed control algorithm is feasible for various types of inelastic structures. While the control efficiency deteriorates with increase in time delay magnitude, PISC shows good performance within a certain range of time delays. More importantly, it is found that a control system with smaller time delay magnitude does not guarantee better performance than that with larger time delay magnitude. Finally, numerical simulation on a six‐storey moment‐resisting frame is performed to demonstrate that PISC gives good control results in a practical inelastic structure. Copyright © 2004 John Wiley & Sons, Ltd.


  • Energy‐based design of structures using modified force analogy method

    by Kevin K. F. Wong, Yi Wang

    Summary: Energy due to earthquake excitations is used to evaluate the performance of a structure. This energy is derived analytically based on the force analogy method, which uses only initial stiffness with changing displacement to accurately capture the inelastic material behaviour. However, numerical calculation using the classical force analogy method considers mass matrices that are invertible, and therefore it is not appropriate for use in analysing real structures where rotational mass moment of inertia is generally ignored. In this research, derivation of the force analogy method is modified to analyse real moment‐resisting frames using static condensation. Using this modified force analogy method in the condensed form significantly reduces the size of the structural problem because a large number of rotational degrees of freedom can be condensed. Numerical simulation is then performed to analyse the dynamic response of a six‐storey moment‐resisting frame and the concept of performance‐based design is used to improve the structural performance in terms of energy dissipation ‘demand’ at each plastic hinge. Results show that the amount of total plastic energy dissipation remains about the same for structures with similar frequency contents. This is significant because it shows that understanding the flow of energy in the structure is important in improving structural performance under earthquake excitations. Copyright © 2003 John Wiley & Sons, Ltd.


  • Effectiveness of structural control based on control energy perspectives

    by Kevin K. F. Wong, Rong Yang

    A computational algorithm for maximizing the control efficiency in actively controlling the elastic structural responses during earthquake is proposed. Study of optimal linear control using a single degree of freedom shows that applying active control is very effective in reducing the structural displacement and velocity responses for long‐period structures, but at the same time it has an adverse effect in increasing the absolute acceleration response. The extent of this adverse effect reduces the effectiveness of the control system, and therefore it poses a limit on the maximum control force in order to provide maximum control efficiency. In view of this shortcoming, maximum control energy dissipation is used to define the most effective optimal linear control law. Less displacement and velocity response are expected as larger control force is applied, but there is always a limit that maximum control energy can be dissipated. This study shows that this limit depends on the structural characteristics as well as the input ground motion, and a general trend is that the maximum control energy decreases as damping increases. Finally, application of the proposed algorithm on a six‐storey hospital building is presented to show the effectiveness of using optimal linear control on a multi‐degree‐of‐freedom system from the control energy perspectives. Copyright © 2001 John Wiley & Sons, Ltd.


  • Energy‐based damage assessment on structures during earthquakes

    by Kevin K. F. Wong, Yumei Wang

    Several seismic damage indices have been developed using the energy concept in attempt to compensate for the inadequacy of ductility criteria. However, these indices are either based on implicitly defined energy as a cumulative effect on ductility or are unable to consider energy in a quantitative manner. In this paper, a method of assessing the structural performance during earthquakes based on both explicitly computed plastic rotation and plastic energy at every hinge of a moment‐resisting frame is proposed. This method uses the force analogy method to evaluate the structural response and energy in the inelastic domain. Inelastic deformation is expected to occur during major earthquakes, and active control based on an instantaneous optimal control algorithm is used to improve the structural performance. Comparisons are made between uncontrolled response and instantaneous optimal control response based on a single‐degree‐of‐freedom system to demonstrate the computation of plastic energy. Damage analysis of a six‐storey moment‐resisting steel frame is then presented to evaluate the performance and applicability of the proposed damage measure. Results show that the proposed damage assessment criteria are feasible and that active control can reduce plastic rotation and plastic energy, thereby reducing damage to a certain acceptable limit. Copyright © 2001 John Wiley & Sons, Ltd.