Xiaoli Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiaoli Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bo Shen
Space Structures Research Center, Guizhou University, Guiyang 550025, China
1 shared publication - Chunmin Dai
Jilin Agricultural University, China
1 shared publication Huichun Zhao
College of Chemistry, Beijing Normal University
1 shared publicationLinpei Jin
College of Chemistry, Beijing Normal University
1 shared publication- Yang Lu
Jilin Agricultural University, China
1 shared publication
Latest Publications
- Open Access
- 1 September 2021
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Medicina do Esporte
- Vol. 27 (3) , 249-252
APPLICATION OF BACK PROPAGATION NEURAL NETWORK IN SPORTS FATIGUE INDICATORS
Introduction High-intensity rehabilitation training will produce exercise fatigue. Objective A backpropagation (BP) network neural algorithm is proposed to predict sports fatigue based on electromyography (EMG) signal images. Methods The principal component analysis algorithm is used to reduce the dimension of EMG signal features. The knee joint angle is estimated by the regularized over-limit learning machine algorithm and the BP neural network algorithm. Results The RMSE value of the regularized over-limit learning machine algorithm is lower than that of the BP neural network algorithm. At the same time, the ρ value of the regularized over-limit learning machine algorithm is closer to 1, indicating its higher accuracy. Conclusions The model training time of the regularized over-limit learning machine algorithm has been greatly reduced, which improves efficiency. Level of evidence II; Therapeutic studies - investigation of treatment results.
- 1 September 2021
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Medicina do Esporte
- Vol. 27 (3) , 249-252
Open AccessAPPLICATION OF BACK PROPAGATION NEURAL NETWORK IN SPORTS FATIGUE INDICATORS
Introduction High-intensity rehabilitation training will produce exercise fatigue. Objective A backpropagation (BP) network neural algorithm is proposed to predict sports fatigue based on electromyography (EMG) signal images. Methods The principal component analysis algorithm is used to reduce the dimension of EMG signal features. The knee joint angle is estimated by the regularized over-limit learning machine algorithm and the BP neural network algorithm. Results The RMSE value of the regularized over-limit learning machine algorithm is lower than that of the BP neural network algorithm. At the same time, the ρ value of the regularized over-limit learning machine algorithm is closer to 1, indicating its higher accuracy. Conclusions The model training time of the regularized over-limit learning machine algorithm has been greatly reduced, which improves efficiency. Level of evidence II; Therapeutic studies - investigation of treatment results.
- Open Access
- 1 September 2021
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Medicina do Esporte
- Vol. 27 (3) , 257-261
EFFECT OF METABOLIC ENZYMES ON ACCELERATION ABILITY IN EXERCISE FATIGUE
Introduction Study the relationship between the metabolic enzyme and the biological image, filtered by an adaptive filtering algorithm. Objective The research aims to In this study, human metabolic enzymes were evaluated by electrocardiogram and electromyogram images, and an adaptive filtering algorithm removed the noises in the images. Methods The electrocardiogram and electromyogram images at different periods were obtained, and the calculation method and application scope of the adaptive filtering algorithm were analysed. Results Adaptive filter was designed by the combination of adaptive filtering algorithm and dynamic information. Therefore, the artefact of the image was removed. Conclusions The adaptive filtering algorithm can effectively remove the noise or artefact in electrocardiogram and electromyogram signals. The optimal image information can be obtained. Level of evidence II; Therapeutic studies - investigation of treatment results.
- 1 September 2021
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Medicina do Esporte
- Vol. 27 (3) , 257-261
Open AccessEFFECT OF METABOLIC ENZYMES ON ACCELERATION ABILITY IN EXERCISE FATIGUE
Introduction Study the relationship between the metabolic enzyme and the biological image, filtered by an adaptive filtering algorithm. Objective The research aims to In this study, human metabolic enzymes were evaluated by electrocardiogram and electromyogram images, and an adaptive filtering algorithm removed the noises in the images. Methods The electrocardiogram and electromyogram images at different periods were obtained, and the calculation method and application scope of the adaptive filtering algorithm were analysed. Results Adaptive filter was designed by the combination of adaptive filtering algorithm and dynamic information. Therefore, the artefact of the image was removed. Conclusions The adaptive filtering algorithm can effectively remove the noise or artefact in electrocardiogram and electromyogram signals. The optimal image information can be obtained. Level of evidence II; Therapeutic studies - investigation of treatment results.
- Open Access
- 10 December 2007
- Published by Springer Nature in Analytical Sciences
- Vol. 23 (12) , 1373-1376
Determination of Ulifloxacin by Terbium-sensitized Fluorescence with Second-order Scattering and Its Applications
This paper reports the determination of ulifloxacin (UFX) by terbium-sensitized fluorescence using a second-order scattering method. UFX and Tb(III) ion form a fluorescence complex in aqueous solution, and its maximum excitation and emission wavelengths are located at 273 and 545 nm, respectively. In optimum conditions, the relative intensity at 545 nm has a linear relationship to the concentration of UFX in the range of 2.0 × 10-8 - 1.0 × 10-5 mol L-1 and the detection limit is 3.9 × 10-9 mol L-1. The proposed method was applied to the determination of UFX in spiked human serum and urine satisfactorily. The luminescence property of UFX is also discussed by comparing with norfloxacin (NFLX) and ofloxacin (OFLX).
- 10 December 2007
- Published by Springer Nature in Analytical Sciences
- Vol. 23 (12) , 1373-1376
Open AccessDetermination of Ulifloxacin by Terbium-sensitized Fluorescence with Second-order Scattering and Its Applications
This paper reports the determination of ulifloxacin (UFX) by terbium-sensitized fluorescence using a second-order scattering method. UFX and Tb(III) ion form a fluorescence complex in aqueous solution, and its maximum excitation and emission wavelengths are located at 273 and 545 nm, respectively. In optimum conditions, the relative intensity at 545 nm has a linear relationship to the concentration of UFX in the range of 2.0 × 10-8 - 1.0 × 10-5 mol L-1 and the detection limit is 3.9 × 10-9 mol L-1. The proposed method was applied to the determination of UFX in spiked human serum and urine satisfactorily. The luminescence property of UFX is also discussed by comparing with norfloxacin (NFLX) and ofloxacin (OFLX).