Aude Silve
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aude Silve has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Wolfgang Frey
4 shared publicationsNatalja Nazarova
3 shared publicationsClair Poignard
Inria Bordeaux, CNRS UMR 5251 &Université de Bordeaux, France
2 shared publications- Guido Link
Karlsruhe Institute of Technology
2 shared publications Ioannis Papachristou
Institute of Process Engineering in Life Science 2: Technical Biology, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publicationsIsabelle Leray
Laboratory of Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ.Paris-Sud, Université Paris-Saclay, Gustave Roussy, PR2, Villejuif, 94805, France
2 shared publications
Latest Publications
- 9 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (9) , 2670-2680
Conception and Development of a Pulsed Microwave Applicator for Exposure of Fresh Microalgae Biomass
This study presents the conception and development of a microwave (MW) applicator based on a TM010 cavity and a pulsed MW source, both custom-designed for evaluation of MW disruption of microalgae. The objective is the selective heating of microalgae immersed in their environment. The applicator enables exposing microalgae suspension to MW in continuous flow mode and monitoring the energy absorbed by the sample. The design was based on dielectric characteristics of microalgae in water, but other solvents might be considered. A tuning element ensures efficient MW coupling into the samples whose relative permittivity ranges from 10 to 80. The applicator includes a customized power supply operating a commercial magnetron source in pulse mode. The MW pulses are in the range of multiple kilowatts with adjustable duration in the microseconds range. The applicator enables to reach a power density in the microalgae sample beyond 10 10 W/m 3 . Preliminary proof-of-principle experiments of MW disruption on fresh microalgae biomass Auxenochlorella protothecoides followed by lipid extraction enabled almost complete lipid recovery, while yields were negligible on untreated samples. Total energy consumption was below 4.2 MJ per kg of dry microalgae. Finally, the applicator characteristics are promising for future upscaling and deployment in the industry.
- 9 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (9) , 2670-2680
Conception and Development of a Pulsed Microwave Applicator for Exposure of Fresh Microalgae Biomass
This study presents the conception and development of a microwave (MW) applicator based on a TM010 cavity and a pulsed MW source, both custom-designed for evaluation of MW disruption of microalgae. The objective is the selective heating of microalgae immersed in their environment. The applicator enables exposing microalgae suspension to MW in continuous flow mode and monitoring the energy absorbed by the sample. The design was based on dielectric characteristics of microalgae in water, but other solvents might be considered. A tuning element ensures efficient MW coupling into the samples whose relative permittivity ranges from 10 to 80. The applicator includes a customized power supply operating a commercial magnetron source in pulse mode. The MW pulses are in the range of multiple kilowatts with adjustable duration in the microseconds range. The applicator enables to reach a power density in the microalgae sample beyond 10 10 W/m 3 . Preliminary proof-of-principle experiments of MW disruption on fresh microalgae biomass Auxenochlorella protothecoides followed by lipid extraction enabled almost complete lipid recovery, while yields were negligible on untreated samples. Total energy consumption was below 4.2 MJ per kg of dry microalgae. Finally, the applicator characteristics are promising for future upscaling and deployment in the industry.
- Open Access
- 11 September 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8
Pulsed Electric Field Treatment Promotes Lipid Extraction on Fresh Oleaginous Yeast Saitozyma podzolica DSM 27192
This study reports on the use of pulsed electric field (PEF) as a pre-treatment step to enhance lipid extraction yield using extraction with ethanol-hexane blend on fresh oleaginous yeast Saitozyma podzolica. The yeasts were cultivated on nitrogen-depleted condition and had a lipid content of 26.4 ± 4.6% of dry weight. PEF-treatment was applied on the yeast suspension either directly after harvesting (unwashed route) or after a washing step (washed route) which induced a reduction of conductivity by a factor eight. In both cases, cell concentration was 20 g of biomass per liter of suspension. In the unwashed route, the lipid extraction efficiency increased from 7% (untreated) to 54% thanks to PEF-treatment. In case an additional washing step was added after PEF-treatment, up to 81% of the lipid content could be recovered. The washed route was even more efficient since lipid extraction yields increased from 26% (untreated) to 99% of total lipid. The energy input for the PEF-treatment never exceeded 150 kJ per liter of initial suspension. The best lipid recovery scenario was obtained using pulses of 1 μs, an electric field of 40 kV/cm and it required slightly less than 11 MJ/kgLIPID. This amount of energy can be further reduced by at least a factor five by optimizing the treatment and especially by increasing the concentration of the treated biomass. The process can be easily up-scaled and does not require any expensive handling of the biomass such as freezing or freeze-drying. These findings demonstrate the potential benefit of PEF-treatment in the downstream processing of oleaginous yeast. From a basic research point of view, the influence of conductivity on PEF energy requirements and extraction yields was examined, and results suggest a higher efficiency of PEF-treatment in terms of energy when treatment is performed at lower conductivity.
- 11 September 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8
Open AccessPulsed Electric Field Treatment Promotes Lipid Extraction on Fresh Oleaginous Yeast Saitozyma podzolica DSM 27192
This study reports on the use of pulsed electric field (PEF) as a pre-treatment step to enhance lipid extraction yield using extraction with ethanol-hexane blend on fresh oleaginous yeast Saitozyma podzolica. The yeasts were cultivated on nitrogen-depleted condition and had a lipid content of 26.4 ± 4.6% of dry weight. PEF-treatment was applied on the yeast suspension either directly after harvesting (unwashed route) or after a washing step (washed route) which induced a reduction of conductivity by a factor eight. In both cases, cell concentration was 20 g of biomass per liter of suspension. In the unwashed route, the lipid extraction efficiency increased from 7% (untreated) to 54% thanks to PEF-treatment. In case an additional washing step was added after PEF-treatment, up to 81% of the lipid content could be recovered. The washed route was even more efficient since lipid extraction yields increased from 26% (untreated) to 99% of total lipid. The energy input for the PEF-treatment never exceeded 150 kJ per liter of initial suspension. The best lipid recovery scenario was obtained using pulses of 1 μs, an electric field of 40 kV/cm and it required slightly less than 11 MJ/kgLIPID. This amount of energy can be further reduced by at least a factor five by optimizing the treatment and especially by increasing the concentration of the treated biomass. The process can be easily up-scaled and does not require any expensive handling of the biomass such as freezing or freeze-drying. These findings demonstrate the potential benefit of PEF-treatment in the downstream processing of oleaginous yeast. From a basic research point of view, the influence of conductivity on PEF energy requirements and extraction yields was examined, and results suggest a higher efficiency of PEF-treatment in terms of energy when treatment is performed at lower conductivity.
- Open Access
- 1 December 2018
- Published by Elsevier in Bioresource Technology
- Vol. 269, 179-187
Incubation time after pulsed electric field treatment of microalgae enhances the efficiency of extraction processes and enables the reduction of specific treatment energy
- 1 December 2018
- Published by Elsevier in Bioresource Technology
- Vol. 269, 179-187
Open AccessIncubation time after pulsed electric field treatment of microalgae enhances the efficiency of extraction processes and enables the reduction of specific treatment energy
- Open Access
- 1 February 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 19957
Impact of external medium conductivity on cell membrane electropermeabilization by microsecond and nanosecond electric pulses
The impact of external medium conductivity on the efficiency of the reversible permeabilisation caused by pulsed electric fields was investigated. Pulses of 12 ns, 102 ns or 100 μs were investigated. Whenever permeabilisation could be detected after the delivery of one single pulse, media of lower conductivity induced more efficient reversible permeabilisation and thus independently of the medium composition. Effect of medium conductivity can however be hidden by some saturation effects, for example when pulses are cumulated (use of trains of 8 pulses) or when the detection method is not sensitive enough. This explains the contradicting results that can be found in the literature. The new data are complementary to those of one of our previous study in which an opposite effect of the conductivity was highlighted. It stresses that the conductivity of the medium influences the reversible permeabilization by several ways. Moreover, these results clearly indicate that electropermeabilisation does not linearly depend on the energy delivered to the cells.
- 1 February 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 19957
Open AccessImpact of external medium conductivity on cell membrane electropermeabilization by microsecond and nanosecond electric pulses
The impact of external medium conductivity on the efficiency of the reversible permeabilisation caused by pulsed electric fields was investigated. Pulses of 12 ns, 102 ns or 100 μs were investigated. Whenever permeabilisation could be detected after the delivery of one single pulse, media of lower conductivity induced more efficient reversible permeabilisation and thus independently of the medium composition. Effect of medium conductivity can however be hidden by some saturation effects, for example when pulses are cumulated (use of trains of 8 pulses) or when the detection method is not sensitive enough. This explains the contradicting results that can be found in the literature. The new data are complementary to those of one of our previous study in which an opposite effect of the conductivity was highlighted. It stresses that the conductivity of the medium influences the reversible permeabilization by several ways. Moreover, these results clearly indicate that electropermeabilisation does not linearly depend on the energy delivered to the cells.
- 1 December 2015
- Published by Elsevier in Bioelectrochemistry
- Vol. 106, 369-378
Cell membrane permeabilization by 12-ns electric pulses: Not a purely dielectric, but a charge-dependent phenomenon
- 1 December 2015
- Published by Elsevier in Bioelectrochemistry
- Vol. 106, 369-378
Cell membrane permeabilization by 12-ns electric pulses: Not a purely dielectric, but a charge-dependent phenomenon
- 23 July 2014
- Published by Elsevier in Bioelectrochemistry
- Vol. 103, 39-43
Image processing for non-ratiometric measurement of membrane voltage using fluorescent reporters and pulsed laser illumination
- 23 July 2014
- Published by Elsevier in Bioelectrochemistry
- Vol. 103, 39-43
Image processing for non-ratiometric measurement of membrane voltage using fluorescent reporters and pulsed laser illumination
- 17 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 61 (7) , 1945-1954
Nanosecond-Duration Electric Pulse Delivery In Vitro and In Vivo: Experimental Considerations
Microsecond-duration electric pulses are widely used for research and therapeutic purposes. The most commonly used device for in vitro exposure to electric pulses is a standard electroporation cuvette. The use of nanosecond-duration electric pulses [nanosecond pulsed electromagnetic fields (nsPEFs) or nanopulses] is an emerging technology. For microsecond pulses, some dedicated generators with voltage regulation have been developed and allow one to easily impose a well-known voltage during biological experiments. However, it is not the case for nsPEF. The application of nsPEF thus requires considering the output impedance of the generator used and the impedance of the biological load because both impose the magnitude and the shape of the applied pulses. The model proposed here describes the behavior of the biological sample on a large frequency band (100 Hz to 3 GHz), including or not the exposure device. This model allows predicting the real electric pulses applied to biological samples and highlights the limitations induced by the use of standard electroporation cuvettes. Considering this kind of application device and the use of 10-ns-duration trapezoidal electric pulses, we evaluate the distortion of the pulses and also the impact of the output impedance of the generator on the steepness of the pulse rising and falling edges. This study is then transposed to potato tuber, a model currently used as a homogeneous biological tissue.
- 17 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 61 (7) , 1945-1954
Nanosecond-Duration Electric Pulse Delivery In Vitro and In Vivo: Experimental Considerations
Microsecond-duration electric pulses are widely used for research and therapeutic purposes. The most commonly used device for in vitro exposure to electric pulses is a standard electroporation cuvette. The use of nanosecond-duration electric pulses [nanosecond pulsed electromagnetic fields (nsPEFs) or nanopulses] is an emerging technology. For microsecond pulses, some dedicated generators with voltage regulation have been developed and allow one to easily impose a well-known voltage during biological experiments. However, it is not the case for nsPEF. The application of nsPEF thus requires considering the output impedance of the generator used and the impedance of the biological load because both impose the magnitude and the shape of the applied pulses. The model proposed here describes the behavior of the biological sample on a large frequency band (100 Hz to 3 GHz), including or not the exposure device. This model allows predicting the real electric pulses applied to biological samples and highlights the limitations induced by the use of standard electroporation cuvettes. Considering this kind of application device and the use of 10-ns-duration trapezoidal electric pulses, we evaluate the distortion of the pulses and also the impact of the output impedance of the generator on the steepness of the pulse rising and falling edges. This study is then transposed to potato tuber, a model currently used as a homogeneous biological tissue.