Manuel Hospinal-Santiani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manuel Hospinal-Santiani has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Ricardo Soccol
Department of Bioprocess Engineering and Biotechnology, Federal University of Paraná (UFPR), Curitiba, Brazil
2 shared publications - Eliézer Lucas Pires Ramos
Federal University of Paraná, Brazil
2 shared publications - Gustavo Martins
Laboratory of Electrochemical Sensors (LabSensE), Department of Chemistry, Federal University of Paraná (UFPR), CP 19032, CEP 81531-980, Curitiba, PR, Brazil
2 shared publications - Luiz Humberto Marcolino Junior
Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil
2 shared publications - Márcio Fernando Bergamini
Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil
2 shared publications - Raphael Aparecido Boschero
Federal University of Paraná, Brazil
2 shared publications
Latest Publications
- Open Access
- 17 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (10) , 885
Graphene-Binding Peptide in Fusion with SARS-CoV-2 Antigen for Electrochemical Immunosensor Construction
The development of immunosensors to detect antibodies or antigens has stood out in the face of traditional methods for diagnosing emerging diseases such as the one caused by the SARS-CoV-2 virus. The present study reports the construction of a simplified electrochemical immunosensor using a graphene-binding peptide applied as a recognition site to detect SARS-CoV-2 antibodies. A screen-printed electrode was used for sensor preparation by adding a solution of peptide and reduced graphene oxide (rGO). The peptide-rGO suspension was characterized by scanning electron microscopy (SEM), Raman spectroscopy, and Fourier transform infrared spectroscopy (FT-IR). The electrochemical characterization (electrochemical impedance spectroscopy—EIS, cyclic voltammetry—CV and differential pulse voltammetry—DPV) was performed on the modified electrode. The immunosensor response is based on the decrease in the faradaic signal of an electrochemical probe resulting from immunocomplex formation. Using the best set of experimental conditions, the analytic curve obtained showed a good linear regression (r2 = 0.913) and a limit of detection (LOD) of 0.77 μg mL−1 for antibody detection. The CV and EIS results proved the efficiency of device assembly. The high selectivity of the platform, which can be attributed to the peptide, was demonstrated by the decrease in the current percentage for samples with antibody against the SARS-CoV-2 S protein and the increase in the other antibodies tested. Additionally, the DPV measurements showed a clearly distinguishable response in assays against human serum samples, with sera with a response above 95% being considered negative, whereas responses below this value were considered positive. The diagnostic platform developed with specific peptides is promising and has the potential for application in the diagnosis of other infections that lead to high antibody titers.
- 17 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (10) , 885
Open AccessGraphene-Binding Peptide in Fusion with SARS-CoV-2 Antigen for Electrochemical Immunosensor Construction
The development of immunosensors to detect antibodies or antigens has stood out in the face of traditional methods for diagnosing emerging diseases such as the one caused by the SARS-CoV-2 virus. The present study reports the construction of a simplified electrochemical immunosensor using a graphene-binding peptide applied as a recognition site to detect SARS-CoV-2 antibodies. A screen-printed electrode was used for sensor preparation by adding a solution of peptide and reduced graphene oxide (rGO). The peptide-rGO suspension was characterized by scanning electron microscopy (SEM), Raman spectroscopy, and Fourier transform infrared spectroscopy (FT-IR). The electrochemical characterization (electrochemical impedance spectroscopy—EIS, cyclic voltammetry—CV and differential pulse voltammetry—DPV) was performed on the modified electrode. The immunosensor response is based on the decrease in the faradaic signal of an electrochemical probe resulting from immunocomplex formation. Using the best set of experimental conditions, the analytic curve obtained showed a good linear regression (r2 = 0.913) and a limit of detection (LOD) of 0.77 μg mL−1 for antibody detection. The CV and EIS results proved the efficiency of device assembly. The high selectivity of the platform, which can be attributed to the peptide, was demonstrated by the decrease in the current percentage for samples with antibody against the SARS-CoV-2 S protein and the increase in the other antibodies tested. Additionally, the DPV measurements showed a clearly distinguishable response in assays against human serum samples, with sera with a response above 95% being considered negative, whereas responses below this value were considered positive. The diagnostic platform developed with specific peptides is promising and has the potential for application in the diagnosis of other infections that lead to high antibody titers.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 64 (spe)
Formulation and Validation of Recombinant Antigens CFP10 and ESAT6 for Tuberculosis Diagnosis
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 64 (spe)
Open AccessFormulation and Validation of Recombinant Antigens CFP10 and ESAT6 for Tuberculosis Diagnosis
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 64 (spe)
A Review on COVID-19 Diagnosis Tests Approved for Use in Brazil and the Impact on Pandemic Control
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 64 (spe)
Open AccessA Review on COVID-19 Diagnosis Tests Approved for Use in Brazil and the Impact on Pandemic Control