Yimin You
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yimin You has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Xiang Li
Department of Instrumental and Electrical Engineering, School of Aerospace Engineering, Xiamen University, Xiamen 361102, China
2 shared publications - Zhongqing Sang
School of Electrical Engineering and Automation, Xiamen University of Technology, Xiamen 361024, China
2 shared publications - Dongyun Dai
School of Electrical Engineering and Automation, Xiamen University of Technology, Xiamen 361024, China
1 shared publication - Jinghui Li
Department of Instrumental and Electrical Engineering, School of Aerospace Engineering, Xiamen University, Xiamen 361102, China
1 shared publication - Maoguang Xu
School of Aerospace Engineering, Xiamen University, Xiamen 361102, China
1 shared publication - Po Li
School of Aerospace Engineering, Xiamen University, Xiamen 361102, China
1 shared publication
Latest Publications
- Open Access
Improved Design of Fuse Tube for Environmental Protection Cabinet Based on Electric-Field Simulation
Since the insulation performance of air is not as good as that of and other gases, it is necessary to conduct an in-depth study on the insulation characteristics of the fuse tube in order to meet the requirements of normal breaking and to design a structural improvement scheme for a 12 kV environmental protection cabinet fuse tube that is suitable for using air as the insulating medium. In this study, the insulation performance of the fuse tube before improvement was studied, and the electric-field distribution of the 12 kV fuse tube placed in the air-insulated switchgear was analyzed. The results showed that the electric-field was heavily concentrated in the air gap of the fuse tube plug and around the ground rod. In this study, the structure of the fuse tube was specifically designed. By spraying conductive paint on the intersection surface of different media, equipotentiality was achieved, and a reasonable metal shielding structure was added to the site where the field intensity was concentrated so as to improve the distribution of the electric-field and avoid the breakdown caused by the concentration of field intensity. Through several improved designs, the maximum electric-field strength of the fuse tube of an environmental protection cabinet can be effectively reduced, and the insulation requirements of relevant standards can be met. A partial discharge test for the improved fuse tube was carried out, and the local discharge quantity of the improved fuse tube met the industry requirements, which verified the rationality of the fuse-tube-improvement scheme.Open AccessImproved Design of Fuse Tube for Environmental Protection Cabinet Based on Electric-Field Simulation
Since the insulation performance of air is not as good as that of and other gases, it is necessary to conduct an in-depth study on the insulation characteristics of the fuse tube in order to meet the requirements of normal breaking and to design a structural improvement scheme for a 12 kV environmental protection cabinet fuse tube that is suitable for using air as the insulating medium. In this study, the insulation performance of the fuse tube before improvement was studied, and the electric-field distribution of the 12 kV fuse tube placed in the air-insulated switchgear was analyzed. The results showed that the electric-field was heavily concentrated in the air gap of the fuse tube plug and around the ground rod. In this study, the structure of the fuse tube was specifically designed. By spraying conductive paint on the intersection surface of different media, equipotentiality was achieved, and a reasonable metal shielding structure was added to the site where the field intensity was concentrated so as to improve the distribution of the electric-field and avoid the breakdown caused by the concentration of field intensity. Through several improved designs, the maximum electric-field strength of the fuse tube of an environmental protection cabinet can be effectively reduced, and the insulation requirements of relevant standards can be met. A partial discharge test for the improved fuse tube was carried out, and the local discharge quantity of the improved fuse tube met the industry requirements, which verified the rationality of the fuse-tube-improvement scheme. - Open Access
An Observer-Based Harmonic Extraction Method with Front SOGI
With the further development of harmonic pollution in the power system, scientists have carried out research on harmonics. Among them, harmonic detection is the first step in harmonic research. In this paper, a harmonic detection method based on an observer is proposed. This method first uses the cascaded Second-Order Generalized Integration (SOGI) algorithm, which can filter the Direct Current (DC) component of the input signal to extract the fundamental frequency, and then uses a time-varying observer to extract the harmonics. This can be used to extract harmonics from a distorted online grid signal. The effectiveness of the proposed method was evaluated on the Speedgoat Rapid Control Prototype (RCP) platform. The results show that it can complete the convergence within 0.05 s, and the standard deviation after stability will not exceed 1%.
Open AccessAn Observer-Based Harmonic Extraction Method with Front SOGI
With the further development of harmonic pollution in the power system, scientists have carried out research on harmonics. Among them, harmonic detection is the first step in harmonic research. In this paper, a harmonic detection method based on an observer is proposed. This method first uses the cascaded Second-Order Generalized Integration (SOGI) algorithm, which can filter the Direct Current (DC) component of the input signal to extract the fundamental frequency, and then uses a time-varying observer to extract the harmonics. This can be used to extract harmonics from a distorted online grid signal. The effectiveness of the proposed method was evaluated on the Speedgoat Rapid Control Prototype (RCP) platform. The results show that it can complete the convergence within 0.05 s, and the standard deviation after stability will not exceed 1%.
- Open Access
- 12 September 2021
- Published by MDPI AG in Mathematics
- Vol. 9 (18) , 2245
A Real-Time Harmonic Extraction Approach for Distorted Grid
Harmonic interference is a major hazard in the current power system that affects power quality. How to extract harmonics quickly and accurately is the premise to ensure the sustainable operation of power system, which is particularly important in the field of new energy power generation. In this paper, a harmonic extraction method based on a time-varying observer is proposed. Firstly, a frequency estimation algorithm is used to estimate the power grid current frequency, which can estimate the frequency in real time. Then, applying the zero-crossing detection method to convert the frequency into a phase variable. Finally, using the phase variable and integral current signal as input, a observer is modeled to extract each order harmonic component. The proposed method is evaluated on a FGPA test platform, which shows that the method can extract the harmonic components of the grid current and converge within 80 ms even in the presence of grid distortions. In the verification case, the relative errors of the 1st, 5th, 7th and 11th harmonics are 0.005%, −0.003%, 0.251% and 0.620%, respectively, which are sufficiently small.
- 12 September 2021
- Published by MDPI AG in Mathematics
- Vol. 9 (18) , 2245
Open AccessA Real-Time Harmonic Extraction Approach for Distorted Grid
Harmonic interference is a major hazard in the current power system that affects power quality. How to extract harmonics quickly and accurately is the premise to ensure the sustainable operation of power system, which is particularly important in the field of new energy power generation. In this paper, a harmonic extraction method based on a time-varying observer is proposed. Firstly, a frequency estimation algorithm is used to estimate the power grid current frequency, which can estimate the frequency in real time. Then, applying the zero-crossing detection method to convert the frequency into a phase variable. Finally, using the phase variable and integral current signal as input, a observer is modeled to extract each order harmonic component. The proposed method is evaluated on a FGPA test platform, which shows that the method can extract the harmonic components of the grid current and converge within 80 ms even in the presence of grid distortions. In the verification case, the relative errors of the 1st, 5th, 7th and 11th harmonics are 0.005%, −0.003%, 0.251% and 0.620%, respectively, which are sufficiently small.