VBVicente Biot-Monterde

Vicente Biot-Monterde

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vicente Biot-Monterde has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnosis of Rotor Asymmetries in Inverter-Fed Wound Rotor Induction Machines via PSH Analysis of Start-Up Vibration

    by Jose E. Ruiz-Sarrio, Pedro Llovera-Segovia, Carlos Madariaga-Cifuentes, Angela Navarro-Navarro, Vicente Biot-Monterde, Jose A. Antonino-Daviu

    Wound Rotor Induction Machines (WRIMs) are widely utilized in industrial applications with high starting torque. The rotor health of such machines influences the machine efficiency and ultimately, the overall safety and reliability. The monitoring of the housing vibrations represent a highly available manner of holistic diagnosis. Nevertheless, the evaluation of rotor health through vibration signals primarily focuses on steady-state operation and has received limited investigation when compared with electrical signature analysis. The present paper introduces a novel technique to diagnose rotor winding asymmetries in WRIMs by analysing the transient evolutions of Principal Slot Harmonic (PSH) families. Particularly, an inverterfed start-up is analysed, which poses increased challenges for rotor defect diagnosis when compared to the line-fed scenario. The methodology exploits the resonance phenomena that arises from the interactions of time evolving forces and structural frequencies. The automatically extracted energy profile of the objective components provides adequate diagnosis and severity identification of three different asymmetry levels at rated load conditions.


  • Open Access

    Investigation on the Use of 2D-DOST on Time–Frequency Representations of Stray Flux Signals for Induction Motor Fault Classification Using a Lightweight CNN Model

    by Geovanni Díaz-Saldaña, Luis Morales-Velazquez, Vicente Biot-Monterde, José Alfonso Antonino-Daviu

    Condition monitoring and fault detection in induction motors (IMs) are priorities in the industrial environment to secure safe conditions for the processes and production. Convolutional Neural Networks (CNNs) are gaining interest in these tasks as they allow automatic extraction of features from the inputs, sometimes Time–Frequency Distributions (TFDs) obtained with various transforms, directly into large models for data classification. This work presents a proposal for the application of a widely used texture analysis tool in the medical field, the 2D Discrete Orthonormal Stockwell Transform (2D-DOST), to improve the accuracy of a lightweight CNN when using different TFDs and comparing the results to the use of the TFDs in RGB and grayscale. The results show that the use of the 2D-DOST improves the classification accuracy in a two to five percent range for all motor conditions under study, while having minimal variations to the training times when compared to RGB or grayscale images, opening the possibility for the use of image processing tools on TFDs to improve automatic feature extraction while using small CNN models.

  • Open Access

    Current- and Vibration-Based Detection of Misalignment Faults in Synchronous Reluctance Motors

    by Angela Navarro-Navarro, Vicente Biot-Monterde, Jose E. Ruiz-Sarrio, Jose A. Antonino-Daviu

    Misalignment faults in drive systems occur when the motor and load are not properly aligned, leading to deviations in the centerlines of the coupled shafts. These faults can cause significant damage to bearings, shafts, and couplings, making early detection essential. Traditional diagnostic techniques rely on vibration monitoring, which provides insights into both mechanical and electromagnetic fault signatures. However, its main drawback is the need for external sensors, which may not be feasible in certain applications. Alternatively, motor current signature analysis (MCSA) has proven effective in detecting faults without requiring additional sensors. This study investigates misalignment faults in synchronous reluctance motors (SynRMs) by analyzing both vibration and current signals under different load conditions and operating speeds. Fast Fourier transform (FFT) is applied to extract characteristic frequency components linked to misalignment. Experimental results reveal that the amplitudes of rotational frequency harmonics (1xfr, 2xfr, and 3xfr) increase in the presence of misalignment, with 1xfr exhibiting the most stable progression. Additionally, acceleration-based vibration analysis proves to be a more reliable diagnostic tool compared to velocity measurements. These findings highlight the potential of combining current and vibration analysis to enhance misalignment detection in SynRMs, improving predictive maintenance strategies in industrial applications.


  • Automatic Detection of Corrosion in Ball Bearings of Soft-Started Induction Motors Using the Persistence Spectrum of the Stray-Flux Signals

    by Vicente Biot-Monterde, Ángela Navarro-Navarro, Israel Zamudio-Ramírez, José A. Antonino-Daviu, Roque A. Osornio-Rios, José E. Ruiz-Sarrió

    This work, presents a novel method to automatically detect and classify the presence of corrosion in ball bearings of soft-started induction motors. The method relies, first, in obtaining the persistence spectrum images of the part of the stray-flux signals in which the soft-starter is in operation. Then, those images are used as input for a convolutional neural network, which automatically differentiates not only between healthy or faulty bearings, but also between different levels of corrosion in the ball bearings. For the study, a soft-starter of a well-known brand is used to start an induction motor, setting different combinations of the variable parameters of that device. Also, different levels of load are applied to the motor. The proposed method proves its potential, achieving a high accuracy.


  • Open Access

    Current and Stray Flux Combined Analysis for Sparking Detection in DC Motors/Generators Using Shannon Entropy

    by Jorge E. Salas-Robles, Vicente Biot-Monterde, Jose A. Antonino-Daviu

    Brushed DC motors and generators (DCMs) are extensively used in various industrial applications, including the automotive industry, where they are critical for electric vehicles (EVs) due to their high torque, power, and efficiency. Despite their advantages, DCMs are prone to premature failure due to sparking between brushes and commutators, which can lead to significant economic losses. This study proposes two approaches for determining the temporal and frequency evolution of Shannon entropy in armature current and stray flux signals. One approach indirectly achieves this through prior analysis using the Short-Time Fourier Transform (STFT), while the other applies the Stockwell Transform (S-Transform) directly. Experimental results show that increased sparking activity generates significant low-frequency harmonics, which are more pronounced compared to mid and high-frequency ranges, leading to a substantial rise in system entropy. This finding enables the introduction of fault-severity indicators or Key Performance Indicators (KPIs) that relate the current condition of commutation quality to a baseline established under healthy conditions. The proposed technique can be used as a predictive maintenance tool to detect and assess sparking phenomena in DCMs, providing early warnings of component failure and performance degradation, thereby enhancing the reliability and availability of these machines.


  • Open Access

    A Review of Broadband Frequency Techniques for Insulation Monitoring and Diagnosis in Rotating Electrical Machines

    by Jose E. Ruiz-Sarrio, Jose A. Antonino-Daviu, Angela Navarro-Navarro, Vicente Biot-Monterde

    Rotating electrical machines greatly suffer from insulation degradation and failure. The adoption of wide band-gap semiconductors in Variable-Frequency Drives (VFDs) hinder the utilization of traditional techniques such as on-line Partial Discharges (PD) to monitor and diagnose the insulation status and failure. Alternative techniques exploiting the broadband frequency behaviour of machine windings, and the increased high-frequency content of VFD excitation arise as a valid alternative. The present work provides a comprehensive analysis and review of cutting-edge broadband frequency techniques aimed to diagnose winding insulation degradation and faults. First, the broadband nature of machine windings is illustrated by explaining the per-turn equivalent circuit and the physical interpretation of its parameters. Then, the different insulation monitoring and diagnosis methods are thoroughly reviewed. The analysed methods include the Frequency Response Analysis (FRA) applied to rotating electrical machines, the analysis of Common Mode (CM) broadband impedance and parasitic capacitances, and methodologies based on the analysis of transient high-frequency current ringing. Specific focus is placed on the instrumentation, which often represents the main applicability limitations.


  • Analysis of Rotor Currents Under the Starting for the Detection of Stator Asymmetries in Wound Rotor Induction Motors

    by Israel Zamudio-Ramirez, Jose A. Antonino-Daviu, Roque Alfredo Osornio-Rios, Larisa Dunai, Vicente Biot-Monterde, Alfredo Quijano-Lopez, Vicente Fuster-Roig

    Wound rotor induction motors (WRIM) are commonly used in applications requiring high starting torques. This is due to the possibility of adding external rheostats in series with the rotor winding that enhance their speed-torque characteristics. However, they are more prone to failures due to their greater constructive complexity. Previous works demonstrated that the combined application of steady-state (Motor Current Signature Analysis) and transient stator current-based methodologies enables a robust diagnosis of rotor asymmetries. However, few works have considered thedetection of stator winding asymmetries (a type of failure that is rather frequent in field WRIM). On the other hand, even fewer works have explored the suitability of rotor current analysis for diagnostic purposes. This work proposes the advanced analysis of rotor currents for the detection of stator asymmetries in WRIM. The proposed novel methodology is based on the combined application of steady-state and transient-based methods to rotor current signals. Unlike what happens in Cage Induction Motors (CIM), rotor currents can be easily measured in WRIM in a simple, reliable and economic way; these are interesting advantages for a reliable WRIM condition monitoring compared to other solutions. The laboratory results prove that it is possible to discern the harmonics caused by different levels of stator asymmetries in the FFT spectrum of steady-state rotor currents. Also, the fault also yields characteristic patterns in the time-frequency maps resulting from the analyses of rotor currents under the starting. These results are validated with an industrial environment in two different large field motors operating in cement plants. This proves the powerfulness of the approach to diagnose the presence of the considered failure.


  • Open Access

    Application of Transient Analysis Techniques to Fault Diagnosis in Low- and Medium-Power Synchronous Machines

    by Angela Navarro-Navarro, Jose E. Ruiz-Sarrio, Vicente Biot-Monterde, Jose A. Antonino-Daviu, Vincent Becker, Sven Urschel

    Fault diagnosis techniques applied to synchronous motors such as Permanent Magnet Synchronous Machines (PMSMs) and Synchronous Reluctance Machines (SynRMs) are scarcely addressed in the literature, in strong contrast to the attention paid to asynchronous motors. In addition, the most widespread techniques are those based on steady-state condition analysis, and little attention is paid to detection during transient operation. The present paper aims to identify research gaps on the topic and to demonstrate the potential of transient analysis. First, the different diagnostic methodologies in literature are thoroughly analyzed. Then, two laboratory case studies are presented to demonstrate the potential of fault detection under non-stationary conditions for a PMSM and a SynRM. Stator current analysis is performed by building time–frequency maps to analyze the evolution of different fault indicators. The results show clear differences between healthy and faulty conditions during the transient regime.


  • Open Access

    Automatic Classification of Rotor Faults in Soft-Started Induction Motors, Based on Persistence Spectrum and Convolutional Neural Network Applied to Stray-Flux Signals

    by Vicente Biot-Monterde, Angela Navarro-Navarro, Israel Zamudio-Ramirez, Jose A. Antonino-Daviu, Roque A. Osornio-Rios

    Due to their robustness, versatility and performance, induction motors (IMs) have been widely used in many industrial applications. Despite their characteristics, these machines are not immune to failures. In this sense, breakage of the rotor bars (BRB) is a common fault, which is mainly related to the high currents flowing along those bars during start-up. In order to reduce the stresses that could lead to the appearance of these faults, the use of soft starters is becoming usual. However, these devices introduce additional components in the current and flux signals, affecting the evolution of the fault-related patterns and so making the fault diagnosis process more difficult. This paper proposes a new method to automatically classify the rotor health state in IMs driven by soft starters. The proposed method relies on obtaining the Persistence Spectrum (PS) of the start-up stray-flux signals. To obtain a proper dataset, Data Augmentation Techniques (DAT) are applied, adding Gaussian noise to the original signals. Then, these PS images are used to train a Convolutional Neural Network (CNN), in order to automatically classify the rotor health state, depending on the severity of the fault, namely: healthy motor, one broken bar and two broken bars. This method has been validated by means of a test bench consisting of a 1.1 kW IM driven by four different soft starters coupled to a DC motor. The results confirm the reliability of the proposed method, obtaining a classification rate of 100.00% when analyzing each model separately and 99.89% when all the models are analyzed at a time.


  • Open Access

    Current and Stray Flux Combined Analysis for the Automatic Detection of Rotor Faults in Soft-Started Induction Motors

    by Angela Navarro-Navarro, Israel Zamudio-Ramirez, Vicente Biot-Monterde, Roque A. Osornio-Rios, Jose A. Antonino-Daviu

    Induction motors (IMs) have been extensively used for driving a wide variety of processes in several industries. Their excellent performance, capabilities and robustness explain their extensive use in several industrial applications. However, despite their robustness, IMs are susceptible to failure, with broken rotor bars (BRB) being one of the potential faults. These types of faults usually occur due to the high current amplitude flowing in the bars during the starting transient. Currently, soft-starters have been used in order to reduce the negative effects and stresses developed during the starting. However, the addition of these devices makes the fault diagnosis a complex and sometimes erratic task, since the typical fault-related patterns evolutions are usually irregular, depending on particular aspects that may change according to the technology implemented by the soft-starter. This paper proposes a novel methodology for the automatic detection of BRB in IMs under the influence of soft-starters. The proposal relies on the combined analysis of current and stray flux signals by means of suitable indicators proposed here, and their fusion through a linear discriminant analysis (LDA). Finally, the LDA output is used to train a feed-forward neural network (FFNN) to automatically detect the severity of the failure, namely: a healthy motor, one broken rotor bar, and two broken rotor bars. The proposal is validated under a testbench consisting of a kinematic chain driven by a 1.1 kW IM and using four different models of soft-starters. The obtained results demonstrate the capabilities of the proposal, obtaining a correct classification rate (94.4% for the worst case).