Keun-Taek Oh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Keun-Taek Oh has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Kyoung-Nam Kim
Research Institute of Dental Biomaterials and Bioengineering, College of Dentistry, Yonsei University, Seoul, Korea
2 shared publicationsJung‐Yoon Choi
Department of Orthodontics, College of Dentistry, Yonsei University, Seoul, South Korea
1 shared publication- Kwang-Mahn Kim
Department and Research Institute of Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, Seoul 03722, Republic of Korea
1 shared publication Kwang‐Chul Choy
Department of Orthodontics, College of Dentistry, Yonsei University, Seoul, South Korea
1 shared publicationKyoung‐Nam Kim
Research Institute and Department of Dental Biomaterials and Bioengineering, College of Dentistry, Yonsei University, Seoul, South Korea
1 shared publication- Kyung-Ho Kim
Department of Orthodontics, Gangnam Severance Hospital, The Institute of Craniofacial Deformity, Yonsei University College of Dentistry, Seoul, South Korea
1 shared publication
Latest Publications
- 18 July 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 80B (2) , 353-359
Photocatalytic antibacterial effect of TiO2 film formed on Ti and TiAg exposed to Lactobacillus acidophilus
When irradiated under near‐ultraviolet (UV) light, TiO2 exhibits strong bactericidal activity. The TiO2 photocatalyst would be effective on orthodontic appliances after its antibacterial effect on the carcinogenic microorganism Lactobacillus acidophilus is evaluated. To compare the antibacterial effect of two crystalline forms of TiO2, rutile and anatase, thermal oxidation and anodic oxidation were employed to form each structure, respectively. The antibacterial effect of TiO2 film on TiAg was also compared with that on Ti. Bacterial solutions were pipetted onto the TiO2‐coated specimen and illuminated with UVA (2 × 15 W, black light, 356 nm) up to 100 min and the reaction solutions were incubated to count the colony‐forming units. The antibacterial activity of the coated specimens was similar to that of the uncoated group. The antibacterial activity of the coated specimens of TiAg was not different from that of Ti. TiO2 coatings formed on both Ti and TiAg specimens did not exhibit cytotoxicity on the L‐929 cells of mice. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007
- 18 July 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 80B (2) , 353-359
Photocatalytic antibacterial effect of TiO2 film formed on Ti and TiAg exposed to Lactobacillus acidophilus
When irradiated under near‐ultraviolet (UV) light, TiO2 exhibits strong bactericidal activity. The TiO2 photocatalyst would be effective on orthodontic appliances after its antibacterial effect on the carcinogenic microorganism Lactobacillus acidophilus is evaluated. To compare the antibacterial effect of two crystalline forms of TiO2, rutile and anatase, thermal oxidation and anodic oxidation were employed to form each structure, respectively. The antibacterial effect of TiO2 film on TiAg was also compared with that on Ti. Bacterial solutions were pipetted onto the TiO2‐coated specimen and illuminated with UVA (2 × 15 W, black light, 356 nm) up to 100 min and the reaction solutions were incubated to count the colony‐forming units. The antibacterial activity of the coated specimens was similar to that of the uncoated group. The antibacterial activity of the coated specimens of TiAg was not different from that of Ti. TiO2 coatings formed on both Ti and TiAg specimens did not exhibit cytotoxicity on the L‐929 cells of mice. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007
- Open Access
- 10 August 2005
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 27 (6) , 533-540
Ion release and cytotoxicity of stainless steel wires
Heat treatment is generally applied to orthodontic stainless steel (SS) wires to relieve the stresses that result from their manipulation by orthodontists. The quality and thickness of the oxide films formed on the surface of heat-treated wires can vary, and it is believed that these oxide films can influence the properties of heat-treated wires. The aim of this study was to investigate the influence of heat treatment and cooling methods on the amount of metal ions released and to examine the cytotoxicity of heat-treated wires. In this study, four types of SS wires (Remanium, Permachrome, Colboloy and Orthos) with a cross-sectional area of 0.41 × 0.56 mm were investigated. These wires were heat-treated in a vacuum, air, or argon environment, and were cooled in either a furnace or a water bath. Four control groups and 24 experimental groups were classified according to the type of wires, heat treatment conditions and cooling methods. In each group, the amount of nickel released as well as its cytotoxicity was investigated. The concentration of dissolved nickel ions in artificial saliva was measured for a period of up to 12 weeks. In all groups, the concentration of dissolved nickel ions in artificial saliva was lowest for the vacuum heat treatment-furnace cooling group and a significant difference was shown compared with the other experimental groups. The concentration of dissolved nickel ions in artificial saliva was highest in the groups heat-treated in air (P < 0.05), while the amount of nickel released was highest in the Remanium and Colboloy (P < 0.05). The cytotoxicity was mild in all the experimental groups but the response index of the air groups was slightly higher than in the other groups. According to these results, SS wires retain their high corrosion resistance and low ion release rate when heat-treated in a vacuum and cooled in a furnace.
- 10 August 2005
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 27 (6) , 533-540
Open AccessIon release and cytotoxicity of stainless steel wires
Heat treatment is generally applied to orthodontic stainless steel (SS) wires to relieve the stresses that result from their manipulation by orthodontists. The quality and thickness of the oxide films formed on the surface of heat-treated wires can vary, and it is believed that these oxide films can influence the properties of heat-treated wires. The aim of this study was to investigate the influence of heat treatment and cooling methods on the amount of metal ions released and to examine the cytotoxicity of heat-treated wires. In this study, four types of SS wires (Remanium, Permachrome, Colboloy and Orthos) with a cross-sectional area of 0.41 × 0.56 mm were investigated. These wires were heat-treated in a vacuum, air, or argon environment, and were cooled in either a furnace or a water bath. Four control groups and 24 experimental groups were classified according to the type of wires, heat treatment conditions and cooling methods. In each group, the amount of nickel released as well as its cytotoxicity was investigated. The concentration of dissolved nickel ions in artificial saliva was measured for a period of up to 12 weeks. In all groups, the concentration of dissolved nickel ions in artificial saliva was lowest for the vacuum heat treatment-furnace cooling group and a significant difference was shown compared with the other experimental groups. The concentration of dissolved nickel ions in artificial saliva was highest in the groups heat-treated in air (P < 0.05), while the amount of nickel released was highest in the Remanium and Colboloy (P < 0.05). The cytotoxicity was mild in all the experimental groups but the response index of the air groups was slightly higher than in the other groups. According to these results, SS wires retain their high corrosion resistance and low ion release rate when heat-treated in a vacuum and cooled in a furnace.
- Open Access
- 1 June 2005
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 27 (3) , 237-244
A stainless steel bracket for orthodontic application
Aesthetics has become an essential element when choosing orthodontic fixed appliances. Most metallic brackets used in orthodontic therapy are made from stainless steel (SS) with the appropriate physical properties and good corrosion resistance, and are available as types 304, 316 and 17-4 PH SS. However, localized corrosion of these materials can frequently occur in the oral environment. This study was undertaken to evaluate the accuracy of sizing, microstructure, hardness, corrosion resistance, frictional resistance and cytotoxicity of commercially available Mini-diamond (S17400), Archist (S30403) and experimentally manufactured SR-50A (S32050) brackets. The size accuracy of Mini-diamond was the highest at all locations except for the external horizontal width of the tie wing (P < 0.05). Micrographs of the Mini-diamond and Archist showed precipitates in the grains and around their boundaries. SR-50A showed the only austenitic phase and the highest polarization resistance of the tested samples. SR-50A also had the highest corrosion resistance [SR-50A, Mini-diamond and Archist were 0.9 × 10−3, 3.7 × 10−3, and 7.4 × 10−3 mm per year (mpy), respectively], in the artificial saliva. The frictional force of SR-50A decreased over time, but that of Mini-diamond and Archist increased. Therefore, SR-50A is believed to have better frictional properties to orthodontic wire than Mini-diamond and Archist. Cytotoxic results showed that the response index of SR-50A was 0/1 (mild), Mini-diamond 1/1 (mild+), and Archist 1/2 (mild+). SR-50A showed greater biocompatibility than either Mini-diamond or Archist. It is concluded that the SR-50A bracket has good frictional property, corrosion resistance and biocompatibility with a lower probability of allergic reaction, compared with conventionally used SS brackets.
- 1 June 2005
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 27 (3) , 237-244
Open AccessA stainless steel bracket for orthodontic application
Aesthetics has become an essential element when choosing orthodontic fixed appliances. Most metallic brackets used in orthodontic therapy are made from stainless steel (SS) with the appropriate physical properties and good corrosion resistance, and are available as types 304, 316 and 17-4 PH SS. However, localized corrosion of these materials can frequently occur in the oral environment. This study was undertaken to evaluate the accuracy of sizing, microstructure, hardness, corrosion resistance, frictional resistance and cytotoxicity of commercially available Mini-diamond (S17400), Archist (S30403) and experimentally manufactured SR-50A (S32050) brackets. The size accuracy of Mini-diamond was the highest at all locations except for the external horizontal width of the tie wing (P < 0.05). Micrographs of the Mini-diamond and Archist showed precipitates in the grains and around their boundaries. SR-50A showed the only austenitic phase and the highest polarization resistance of the tested samples. SR-50A also had the highest corrosion resistance [SR-50A, Mini-diamond and Archist were 0.9 × 10−3, 3.7 × 10−3, and 7.4 × 10−3 mm per year (mpy), respectively], in the artificial saliva. The frictional force of SR-50A decreased over time, but that of Mini-diamond and Archist increased. Therefore, SR-50A is believed to have better frictional properties to orthodontic wire than Mini-diamond and Archist. Cytotoxic results showed that the response index of SR-50A was 0/1 (mild), Mini-diamond 1/1 (mild+), and Archist 1/2 (mild+). SR-50A showed greater biocompatibility than either Mini-diamond or Archist. It is concluded that the SR-50A bracket has good frictional property, corrosion resistance and biocompatibility with a lower probability of allergic reaction, compared with conventionally used SS brackets.