JCJoao L. A. Carvalho

Joao L. A. Carvalho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joao L. A. Carvalho has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A New Model for Programming Software in Body Sensor Networks

    by Talles M. G. de A. Barbosa, Iwens G. Sene, Adson F. da Rocha, Francisco A. de O. Nascimento, Joao L. A. Carvalho, Hervaldo S. Carvalho

    A body sensor network (BSN) must be designed to work autonomously. On the other hand, BSNs need mechanisms that allow changes in their behavior in order to become a clinically useful tool. The purpose of this paper is to present a new programming model that will be useful for programming BSN sensor nodes. This model is based on an intelligent intermediate-level compiler. The main purpose of the proposed compiler is to increase the efficiency in system use, and to increase the lifetime of the application, considering its requirements, hardware possibilities and specialist knowledge. With this model, it is possible to maintain the autonomous operation capability of the BSN and still offer tools that allow users with little grasp on programming techniques to program these systems.

  • A New Wavelet-Based Algorithm for Compression of Emg Signals

    by Pedro de A. Berger, Francisco A. de O. Nascimento, Adson F. da Rocha, Joao L. A. Carvalho

    Despite the growing interest in the transmission and storage of electromyographic signals for long periods of time, only a few studies dealt with the compression of these signals. In this article we propose a novel algorithm for EMG signal compression using the wavelet transform. For EMG signals acquired during isometric contractions, the proposed algorithm provided compression factors ranging from 50 to 90%, with an average PRD ranging from 1.4 to 7.5%. The proposed method uses a new scheme for normalizing the wavelet coefficients. The wavelet coefficients are quantized using dynamic bit allocation, which is carried out by a Kohonen Neural Network. After the quantization, these coefficients are encoded using an arithmetic encoder. The compression results using the proposed algorithm were compared to other algorithms based on the wavelet transform. The proposed algorithm had a better performance in compression ratio and fidelity of the reconstructed signal.


  • A Framework for Automated Evidence Gathering with Mobile Systems Using Bayesian Networks

    by A. B. Jose, T. M. G. de A. Barbosa, I. G. Sene, A. F. da Rocha, L. S. da S. Castro, F. A. de O. Nascimento, J. L. A. Carvalho, H. S. Carvalho

    This article presents a framework that allows the automated gathering of medical evidence, using a methodology based on Bayesian networks (BN). For such purpose, system software and a programming methodology were developed. The proposed methodology is generic and can be applied to different contexts (application domains) were evidence gathering is executed in mobile devices.


  • Open Access

    Rapid quantitation of cardiovascular flow using slice‐selective fourier velocity encoding with spiral readouts

    by Joao L. A. Carvalho, Krishna S. Nayak

    Accurate flow visualization and quantitation is important for the assessment of many cardiovascular conditions such as valvular stenosis and regurgitation. Phase contrast based methods experience partial volume artifacts when flow is highly localized, complex and/or turbulent. Fourier velocity encoding (FVE) avoids such problems by resolving the full velocity distribution within each voxel. This work proposes the use of slice selective FVE with spiral readouts to acquire fully localized velocity distributions in a short breath-hold. Scan-plane prescription is performed using classic protocols, and an automatic algorithm is used for in-plane localization of the flow. Time and spatially-resolved aortic valve velocity distributions with 26-msec temporal resolution and 25 cm/sec velocity resolution over a 600 cm/sec field-of-view were acquired in a 12-heartbeat breath-hold. In carotid studies, scan time was extended to achieve higher spatial resolution. The method was demonstrated in healthy volunteers and patients, and the results compared qualitatively well with Doppler ultrasound. Acquisition time could be reduced to 7 heartbeats (a 42% reduction) using partial Fourier reconstruction along the velocity dimension. Magn Reson Med 57:639–646, 2007.