Maryam Tabrizian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maryam Tabrizian has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
L'H. Yahia
Biomedical Engineering Institute, École Polytechnique, PO Box 6079, Montréal, Quebec H3C 3A7, Canada
3 shared publications- Benjamin Thierry
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095, Australia
2 shared publications Charles-Hilaire Rivard
Research Center, Sainte–Justine Hospital, Montreal, Quebec, Canada
2 shared publicationsEsteban Chornet
Department of Chemical Engineering, University of Sherbrooke, Sherbrooke, Quebec, J1K 2R1, Canada
2 shared publicationsFatiha Chellat
Biomedical Engineering Institute, Biomechanics and Biomaterials Research Group, Ecole Polytechnique, Montreal, Quebec, H3C 3A7, Canada
2 shared publicationsO. Savadogo
Physics and Materials Engineering Department, Ecole Polytechnique of Montreal, Montreal, C.P. 6079, Succ. “Centre ville,” Montreal, Quebec H3C 3A7, Canada
2 shared publications
Latest Publications
- 3 October 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 52 (4) , 774-782
Plasma‐based sterilization: Effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters
- 3 October 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 52 (4) , 774-782
Plasma‐based sterilization: Effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters
- 1 September 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 53 (5) , 592-599
Study of biodegradation behavior of chitosan-xanthan microspheres in simulated physiological media
Microspheres of a polyelectrolyte complex hydrogel were prepared from chitosan and xanthan after interaction between the two polyionic polymers. Their biodegradation was studied vs. chitosan. Simulated gastric fluid (SGF, pH 1.2) and intestinal fluid (SIF, pH 7.5) both as biodegradation media and phosphate buffered saline (PBS, pH 7.4) as a negative control were used. The degradation studies were performed at 37°C at 240 rpm permanent stirring to mimic the physiologic conditions. High performance liquid chromatography (HPLC) was carried out to quantify the chitosan degradation products using glucosamine (GA) and N-acetyl-D-glucosamine (N-Ac-GA) as references. The peaks area integration method was used to determine the amount of each degradation product as a function of incubation time in the media. The effect of the media on the morphological structure of microspheres was assessed by scanning electron microscopy. From HPLC studies, it appeared that in SGF and SIF the major degradation products were glucosamine (GA) and N-acetyl-D-glucosamine (NAc-GA). In the first 15 days, oligochitosan fractions were released from the complex, whereas N-acetyl-D-glucosamine was detected in the media after this period. The degradation kinetics were assessed by the measurement of the cumulative degradation products, which showed faster degradation of chitosan than the complex in SGF and SIF. SEM micrographs showed an enhancement of microsphere porosity as a function of incubation time in the simulated physiological media. Our results suggest a better control of the degradation kinetics when chitosan is complexed to xanthan. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 53: 592–599, 2000
- 1 September 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 53 (5) , 592-599
Study of biodegradation behavior of chitosan-xanthan microspheres in simulated physiological media
Microspheres of a polyelectrolyte complex hydrogel were prepared from chitosan and xanthan after interaction between the two polyionic polymers. Their biodegradation was studied vs. chitosan. Simulated gastric fluid (SGF, pH 1.2) and intestinal fluid (SIF, pH 7.5) both as biodegradation media and phosphate buffered saline (PBS, pH 7.4) as a negative control were used. The degradation studies were performed at 37°C at 240 rpm permanent stirring to mimic the physiologic conditions. High performance liquid chromatography (HPLC) was carried out to quantify the chitosan degradation products using glucosamine (GA) and N-acetyl-D-glucosamine (N-Ac-GA) as references. The peaks area integration method was used to determine the amount of each degradation product as a function of incubation time in the media. The effect of the media on the morphological structure of microspheres was assessed by scanning electron microscopy. From HPLC studies, it appeared that in SGF and SIF the major degradation products were glucosamine (GA) and N-acetyl-D-glucosamine (NAc-GA). In the first 15 days, oligochitosan fractions were released from the complex, whereas N-acetyl-D-glucosamine was detected in the media after this period. The degradation kinetics were assessed by the measurement of the cumulative degradation products, which showed faster degradation of chitosan than the complex in SGF and SIF. SEM micrographs showed an enhancement of microsphere porosity as a function of incubation time in the simulated physiological media. Our results suggest a better control of the degradation kinetics when chitosan is complexed to xanthan. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 53: 592–599, 2000
- 1 July 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 51 (1) , 107-116
In vitro andin vivo biocompatibility of chitosan-xanthan polyionic complex
A novel hydrogel, CHITOXANTM (CH-X), has potential as a vehicle for controlled drug delivery. The hydrogel is obtained by complexation of two polysaccharides, chitosan and xanthan. In the present work we investigated the biocompatibility of the complex using in vitro and in vivo models. The cytotoxic effects of CH-X microspheres as well as their degradation products at different concentrations were assessed on fibroblasts (fibroblast cell line L-929) using 3-(4,5-dimethylthiazole-2yl)-2,5-triphenyl tetrazolium) (MTT). The test is based on mitochondrial dehydrogenase cell activity as an indicator of cell viability. Interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) cytokines as well as nitric oxide (NO) production by macrophages (macrophage cell line J-774) were examined as indicators of cell activation. In vivo biocompatibility assessment was performed for 1 to 12 weeks. This study was performed using tablets obtained after compression of CH-X particles implanted at the subcutaneous level in male Wistar rats. CH-X biocompatibility and degradation were investigated using histological studies. Light and transmission electron microscopy (TEM) analyses were used to determine the foreign-body reaction and phagocytosis of the implants by macrophages. Fibroblast exposition to CH-X particles and degradation products did not show cytotoxic effects as measured by MTT test. TNF-α production was dependent on CH-X particles concentration, whereas IL-1β production was found to be dose independent. CH-X extract products stimulated TNF-α secretion when used at the highest concentration (10 mg/mL), notably after 28 days' degradation time. No effect was observed on IL-1β production when CH-X extracts were used in comparison to the control. The effects of CH-X particles on NO secretion were similar as on TNF-α. Histological studies showed that CH-X tablets broke down into particles which progressively degraded into smaller fragments. A significant fraction of the fragments was ingested by the macrophages after 12 weeks of implantation. Light microscopy studies showed a weak foreign-body reaction as a function of time and the fibrous layer thickness decreased with time of implantation. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 51, 107–116, 2000.
- 1 July 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 51 (1) , 107-116
In vitro andin vivo biocompatibility of chitosan-xanthan polyionic complex
A novel hydrogel, CHITOXANTM (CH-X), has potential as a vehicle for controlled drug delivery. The hydrogel is obtained by complexation of two polysaccharides, chitosan and xanthan. In the present work we investigated the biocompatibility of the complex using in vitro and in vivo models. The cytotoxic effects of CH-X microspheres as well as their degradation products at different concentrations were assessed on fibroblasts (fibroblast cell line L-929) using 3-(4,5-dimethylthiazole-2yl)-2,5-triphenyl tetrazolium) (MTT). The test is based on mitochondrial dehydrogenase cell activity as an indicator of cell viability. Interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) cytokines as well as nitric oxide (NO) production by macrophages (macrophage cell line J-774) were examined as indicators of cell activation. In vivo biocompatibility assessment was performed for 1 to 12 weeks. This study was performed using tablets obtained after compression of CH-X particles implanted at the subcutaneous level in male Wistar rats. CH-X biocompatibility and degradation were investigated using histological studies. Light and transmission electron microscopy (TEM) analyses were used to determine the foreign-body reaction and phagocytosis of the implants by macrophages. Fibroblast exposition to CH-X particles and degradation products did not show cytotoxic effects as measured by MTT test. TNF-α production was dependent on CH-X particles concentration, whereas IL-1β production was found to be dose independent. CH-X extract products stimulated TNF-α secretion when used at the highest concentration (10 mg/mL), notably after 28 days' degradation time. No effect was observed on IL-1β production when CH-X extracts were used in comparison to the control. The effects of CH-X particles on NO secretion were similar as on TNF-α. Histological studies showed that CH-X tablets broke down into particles which progressively degraded into smaller fragments. A significant fraction of the fragments was ingested by the macrophages after 12 weeks of implantation. Light microscopy studies showed a weak foreign-body reaction as a function of time and the fibrous layer thickness decreased with time of implantation. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 51, 107–116, 2000.
- 28 June 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 51 (4) , 685-693
Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
Nickel‐titanium (NiTi) alloy derives its biocompatibility and good corrosion resistance from a homogeneous oxide layer mainly composed of TiO2, with a very low concentration of nickel. In this article, we described the corrosion behavior of NiTi alloys after mechanical polishing, electropolishing, and sterilization processes using cyclic polarization and atomic absorption. As a preparative surface treatment, electropolishing decreased the amount of nickel on the surface and remarkably improved the corrosion behavior of the alloy by increasing the mean breakdown potential value and the reproducibility of the results (0.99 ± 0.05 V/SCE vs. 0.53 ± 0.42). Ethylene oxide and Sterrad® sterilization techniques did not modify the corrosion resistance of electropolished NiTi, whereas a steam autoclave and, to a lesser extent, peracetic acid sterilization produced scattered breakdown potential. In comparing the corrosion resistance of common biomaterials, NiTi ranked between 316L stainless steel and Ti6A14V even after sterilization. Electropolished NiTi and 316L stainless‐steel alloys released similar amounts of nickel after a few days of immersion in Hank's solution. Measurements by atomic absorption have shown that the amount of released nickel from passive dissolution was below the expected toxic level in the human body. Auger electron spectroscopy analyses indicated surface contamination by Ca and P on NiTi during immersion, but no significant modification in oxide thickness was observed. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 51, 685–693, 2000.
- 28 June 2000
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 51 (4) , 685-693
Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
Nickel‐titanium (NiTi) alloy derives its biocompatibility and good corrosion resistance from a homogeneous oxide layer mainly composed of TiO2, with a very low concentration of nickel. In this article, we described the corrosion behavior of NiTi alloys after mechanical polishing, electropolishing, and sterilization processes using cyclic polarization and atomic absorption. As a preparative surface treatment, electropolishing decreased the amount of nickel on the surface and remarkably improved the corrosion behavior of the alloy by increasing the mean breakdown potential value and the reproducibility of the results (0.99 ± 0.05 V/SCE vs. 0.53 ± 0.42). Ethylene oxide and Sterrad® sterilization techniques did not modify the corrosion resistance of electropolished NiTi, whereas a steam autoclave and, to a lesser extent, peracetic acid sterilization produced scattered breakdown potential. In comparing the corrosion resistance of common biomaterials, NiTi ranked between 316L stainless steel and Ti6A14V even after sterilization. Electropolished NiTi and 316L stainless‐steel alloys released similar amounts of nickel after a few days of immersion in Hank's solution. Measurements by atomic absorption have shown that the amount of released nickel from passive dissolution was below the expected toxic level in the human body. Auger electron spectroscopy analyses indicated surface contamination by Ca and P on NiTi during immersion, but no significant modification in oxide thickness was observed. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 51, 685–693, 2000.
- 12 November 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 49 (1) , 88-98
Effects of sterilization processes on NiTi alloy: Surface characterization
Sterilization is required for using any device in contact with the human body. Numerous authors have studied device properties after sterilization and reported on bulk and surface modifications of many materials after processing. These surface modifications may in turn influence device biocompatibility. Still, data are missing on the effect of sterilization procedures on new biomaterials such as nickel-titanium (NiTi). Herein we report on the effect of dry heat, steam autoclaving, ethylene oxide, peracetic acid, and plasma-based sterilization techniques on the surface properties of NiTi. After processing electropolished NiTi disks with these techniques, surface analyses were performed by Auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements. AES analyses revealed a higher Ni concentration (6–7 vs. 1%) and a slightly thicker oxide layer on the surface for heat and ethylene oxide processed materials. Studies of surface topography by AFM showed up to a threefold increase of the surface roughness when disks were dry heat sterilized. An increase of the surface energy of up to 100% was calculated for plasma treated surfaces. Our results point out that some surface modifications are induced by sterilization procedures. Further work is required to assess the effect of these modifications on biocompatibility, and to determine the most appropriate methods to sterilize NiTi. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 49, 88–98, 2000.
- 12 November 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 49 (1) , 88-98
Effects of sterilization processes on NiTi alloy: Surface characterization
Sterilization is required for using any device in contact with the human body. Numerous authors have studied device properties after sterilization and reported on bulk and surface modifications of many materials after processing. These surface modifications may in turn influence device biocompatibility. Still, data are missing on the effect of sterilization procedures on new biomaterials such as nickel-titanium (NiTi). Herein we report on the effect of dry heat, steam autoclaving, ethylene oxide, peracetic acid, and plasma-based sterilization techniques on the surface properties of NiTi. After processing electropolished NiTi disks with these techniques, surface analyses were performed by Auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements. AES analyses revealed a higher Ni concentration (6–7 vs. 1%) and a slightly thicker oxide layer on the surface for heat and ethylene oxide processed materials. Studies of surface topography by AFM showed up to a threefold increase of the surface roughness when disks were dry heat sterilized. An increase of the surface energy of up to 100% was calculated for plasma treated surfaces. Our results point out that some surface modifications are induced by sterilization procedures. Further work is required to assess the effect of these modifications on biocompatibility, and to determine the most appropriate methods to sterilize NiTi. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 49, 88–98, 2000.