JZJin Zhang

Jin Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jin Zhang has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Qingxi Yuan

    Chinese Academy of Sciences

    5 shared publications
  • Kai Zhang

    4 shared publications
  • Piero Pianetta

    Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, USA

    3 shared publications
  • Shanfeng Wang

    Beijing Synchrotron Radiation Facility, X-ray Optics and Technology Laboratory, Institute of High Energy Physics, Chinese Academy of Sciences, Yuquan Road, Shijingshan District, Beijing 100049, People’s Republic of China

    3 shared publications
  • Tianyu Fu

    University of Chinese Academy of Sciences

    3 shared publications
  • Wanxia Huang

    Beijing Synchrotron Radiation Facility, X-ray Optics and Technology Laboratory, Institute of High Energy Physics, Chinese Academy of Sciences, Yuquan Road, Shijingshan District, Beijing 100049, People’s Republic of China

    3 shared publications

Latest Publications

  • Open Access

    Protocol for CANet-based deformation-corrected chemical mapping in X-ray spectro-tomography

    by Ting Wang, Zipei Yan, Hongyi Pan, Kai Zhang, Michael K.-P. Ng, Jin Zhang, Xiqian Yu, Chao Wang, Jizhou Li

  • Open Access

    Compound Augmentation of Myocardial Injury in a Rat Model of Coronary Heart Disease Induced by Ischemia/Reperfusion, Rheumatoid Arthritis, and High-Fat Diet: A Molecular Mechanistic Study

    by Qixiang Xu, Jin Zhang, Lvming Li, Zhen Zhang, Zui Pan, Yongqiu Zheng

    Aims: Coronary heart disease (CHD) associated with rheumatoid arthritis (RA) is a primary driver of mortality in RA patients. In this study, we sought to establish a combined rat model of CHD and RA by integrating cardiac ischemia/reperfusion (I/R), high-fat diet (HFD), and intradermal administration of bovine type II collagen emulsified in complete Freund’s adjuvant. The aim of constructing this model is to investigate and analyze the pathogenesis of RA-induced CHD under the modulation of HFD and cardiac I/R exposure. Methods and Results: Sixty-four male Sprague–Dawley rats were randomly categorized into eight groups (n = 8 per group): control, I/R, HFD, collagen-induced arthritis (CIA), I/R + CIA, HFD + CIA, I/R + HFD, and I/R + HFD + CIA groups (n = 8 per group). We applied Synchrotron radiation-based X-ray micro-computed tomography (micro-CT) to observe the structural changes within the model over time. To further elucidate molecular mechanisms, transcriptome RNA-seq analysis was carried out to identify key signaling pathways, with particular emphasis on the homeostasis of Toll-like receptor 4 (TLR4)/Myd88 signaling in the ischemic myocardium. Furthermore, we conducted in vivo shRNA-mediated knockdown of polymerase I and transcription release factor (PTRF) and evaluated the co-localization of PTRF and TLR4 through immunofluorescence experiments. It is worth mentioning that our rat model of RA-induced (CHD) under a high-fat diet effectively manifested the relevant pathological features that align with the Traditional Chinese Medicine (TCM) definition of “bi” syndrome. The results indicate that the combined stimulation of HFD and CIA significantly elevated cardiac injury markers (CK-MB, LDH, CRP, and c-TNT) and was accompanied by a more severe expansion of the infarct area and increased cardiomyocyte apoptosis compared to the I/R group alone. In addition, the histopathological evaluation revealed significantly aggravated myocardial inflammation and fibrosis deposition, accompanied by extensive areas of tissue damage, further indicating a state of heightened inflammation and severe cardiac degenerative changes. Consistently, myocardial tissues from rats in the I/R + CIA + HFD group exhibited robust activation of the TLR4/MyD88 signaling pathway and a pronounced elevation in the p-JNK/JNK ratio. Moreover, pronounced co-localization between PTRF and TLR4 was evident in small vessels surrounding the infarcted myocardium. Importantly, AAV-mediated knockdown of PTRF attenuated the HFD- and CIA-induced exacerbation of myocardial injury in I/R rats. Conclusions: We successfully established a rat model of CHD with rheumatic syndrome using I/R in combination with RA and HFD. The present findings suggest that the PTRF-related TLR4/MyD88-JNK signaling pathway may act as an important regulatory mechanism underlying myocardial injury aggravated by combined HFD and CIA stimulation.

  • Super-resolution x-ray imaging technology based on U-shaped Residual Transformer Generative Adversarial Network

    by Xinyu Zhao, Yan Wang, Chenpeng Zhou, Jin Zhang, Shanfeng Wang, Wanxia Huang, Kai Zhang, Qingxi Yuan

    Current x-ray imaging technologies have difficulties in achieving higher resolution, because the fabrication of optical components with superior performance remains a challenge. Here, a super-resolution technology based on the U-shaped-residual-transformer-generative adversarial network (URT-GAN) network is proposed, which synergizes a transformer-based denoising module and a GAN-based resolution enhancement module. Through resolution test patterns and real sample datasets, the effectiveness and wide applicability of this method has been demonstrated and validated from both quantitative and qualitative perspectives. Without altering the existing hardware conditions, it can still achieve higher resolution x-ray imaging through adoption of the URT-GAN network. The source code will be released along with this paper and we welcome our colleagues in the field to adopt and improve upon it.


  • Nanoscale analysis of magnetic chains consisting of cobalt mesospheres by full‐field transmission x‐ray tomography

    by Jin Zhang, Chenpeng Zhou, Wanxia Huang, Shanfeng Wang, Yan Wang

    Full‐field transmission x‐ray tomography can obtain 3D morphology and configurations of nanoscale materials. In this study, we further demonstrate the feasibility of this technique using magnetic chains consisting of cobalt mesospheres. The preliminary images presented in this article clearly reveal that three types of cobalt nanoparticles, namely, hollow, core–shell, and solid were found for magnetic chain synthesis. Furthermore, the tomographic analyses revealed the growth mechanism of magnetic chains self‐assembled by cobalt nanoparticles. We may claim that the spatial resolution and contrast characteristics of the full‐field transmission x‐ray tomography can satisfy the research requirements of nanomaterial science. Hence, transmission x‐ray tomography could be a powerful complementary method for imaging and analysis of nanoscale materials.

  • Correction of ring artifacts with Swin-Conv-U-Net for x-ray computed tomography

    by Tianyu Fu, Sen Qiu, Yan Wang, Kai Zhang, Jin Zhang, Shanfeng Wang, Wanxia Huang, Chenpeng Zhou, XinYu Zhao, Ye Tao, et al.

    X-ray tomography is widely used in diverse research domains owing to its capacity for observing high-resolution three-dimensional structures nondestructively. However, ring artifacts appear in the tomographic reconstruction because of the inconsistent response of detector pixels, seriously affecting the image quality and causing nonuniform bias. To solve this problem, a method for correction of ring artifacts based on Swin-Conv-U-Net is proposed for x-ray tomography. When applied to simulation and experimental data, the proposed method achieves high accuracy and strong robustness and shows advantages over several classical methods in quantitative and qualitative evaluation.


  • Open Access

    Deep-learning-based ring artifact correction for tomographic reconstruction

    by Tianyu Fu, Yan Wang, Kai Zhang, Jin Zhang, Shanfeng Wang, Wanxia Huang, Yaling Wang, Chunxia Yao, Chenpeng Zhou, Qingxi Yuan

    X-ray tomography has been widely used in various research fields thanks to its capability of observing 3D structures with high resolution non-destructively. However, due to the nonlinearity and inconsistency of detector pixels, ring artifacts usually appear in tomographic reconstruction, which may compromise image quality and cause nonuniform bias. This study proposes a new ring artifact correction method based on the residual neural network (ResNet) for X-ray tomography. The artifact correction network uses complementary information of each wavelet coefficient and a residual mechanism of the residual block to obtain high-precision artifacts through low operation costs. In addition, a regularization term is used to accurately extract stripe artifacts in sinograms, so that the network can better preserve image details while accurately separating artifacts. When applied to simulation and experimental data, the proposed method shows a good suppression of ring artifacts. To solve the problem of insufficient training data, ResNet is trained through the transfer learning strategy, which brings advantages of robustness, versatility and low computing cost.


  • In-Situ Visualization of the Transition Metal Dissolution in Layered Cathodes

    by Guannan Qian, Guibin Zan, Jizhou Li, Jin Zhang, Piero Pianetta, Yijin Liu

    Transition metal dissolution in layered cathodes is one of the most intractable issues that deteriorate the battery performance and lifetime. It not only aggravates the structure degradation in cathode but also damages the solid electrolyte interphase in anode and even induces the formation of lithium dendrites. In this work, we investigate the dissolution behaviors of polycrystalline and single-crystalline layered cathode via operando X-ray imaging techniques. The cathode particle morphology appears to have a significant impact on the evolution of the dissolution dynamics. As a mitigation strategy, we reveal that doping with a trace amount of Zr in the layered cathode could improve its robustness against the transition metal dissolution. Our finding provides valuable insights for designing the next-generation highly stable layered battery cathodes.


  • Deep-learning-based image registration for nano-resolution tomographic reconstruction

    by Tianyu Fu, Kai Zhang, Yan Wang, Jizhou Li, Jin Zhang, Chunxia Yao, Qili He, Shanfeng Wang, Wanxia Huang, Qingxi Yuan, et al.

    Nano-resolution full-field transmission X-ray microscopy has been successfully applied to a wide range of research fields thanks to its capability of non-destructively reconstructing the 3D structure with high resolution. Due to constraints in the practical implementations, the nano-tomography data is often associated with a random image jitter, resulting from imperfections in the hardware setup. Without a proper image registration process prior to the reconstruction, the quality of the result will be compromised. Here a deep-learning-based image jitter correction method is presented, which registers the projective images with high efficiency and accuracy, facilitating a high-quality tomographic reconstruction. This development is demonstrated and validated using synthetic and experimental datasets. The method is effective and readily applicable to a broad range of applications. Together with this paper, the source code is published and adoptions and improvements from our colleagues in this field are welcomed.


  • Automatic 3D image registration for nano-resolution chemical mapping using synchrotron spectro-tomography

    by Jin Zhang, Jun Hu, Zhisen Jiang, Kai Zhang, Peng Liu, Chaonan Wang, Qingxi Yuan, Piero Pianetta, Yijin Liu

    Nano-resolution synchrotron X-ray spectro-tomography has been demonstrated as a powerful tool for probing the three-dimensional (3D) structural and chemical heterogeneity of a sample. By reconstructing a number of tomographic data sets recorded at different X-ray energy levels, the energy-dependent intensity variation in every given voxel fingerprints the corresponding local chemistry. The resolution and accuracy of this method, however, could be jeopardized by non-ideal experimental conditions, e.g. instability in the hardware system and/or in the sample itself. Herein is presented one such case, in which unanticipated sample deformation severely degrades the data quality. To address this issue, an automatic 3D image registration method is implemented to evaluate and correct this effect. The method allows the redox heterogeneity in partially delithiated Li x Ta0.3Mn0.4O2 battery cathode particles to be revealed with significantly improved fidelity.