- 3 April 2022
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 6806-6828
Heat transfer analysis of double discrete arc roughness with different relative rib altitudes and relate to a single discrete arc in the solar air heater
Artificially roughened solar air heater (SAH) with double discrete arc roughness is experimentally explored in this paper. Relative rib altitude (e/Dh) varies from 0.018 to 0.034 while constant relative rib pitch (P/e), staggered pitch ratio (P’/P) and segment ratio (S’/S) of 10, 0.5 and 1.6 respectively is considered. The Reynolds number (Re) value varies from 3000 to 14000. Augmented Stanton number (St) and thermo-hydraulic performance (THPP) with moderate friction factor (f) is reported for e/Dh of 0.034. The maximum St and f of 2.32 and 3.10 times respectively is resulted for rough plate related to plain configuration while THPP of roughened SAH is augmented up to 1.60. The outcomes of present roughness are compared with single discrete and continuous arc geometry under identical flow state and confirm the superior performance under the range of parameters tested. The correlations for heat transfer function (G) and roughness function (R) are also developed.
- 3 April 2022
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 6806-6828
Heat transfer analysis of double discrete arc roughness with different relative rib altitudes and relate to a single discrete arc in the solar air heater
Artificially roughened solar air heater (SAH) with double discrete arc roughness is experimentally explored in this paper. Relative rib altitude (e/Dh) varies from 0.018 to 0.034 while constant relative rib pitch (P/e), staggered pitch ratio (P’/P) and segment ratio (S’/S) of 10, 0.5 and 1.6 respectively is considered. The Reynolds number (Re) value varies from 3000 to 14000. Augmented Stanton number (St) and thermo-hydraulic performance (THPP) with moderate friction factor (f) is reported for e/Dh of 0.034. The maximum St and f of 2.32 and 3.10 times respectively is resulted for rough plate related to plain configuration while THPP of roughened SAH is augmented up to 1.60. The outcomes of present roughness are compared with single discrete and continuous arc geometry under identical flow state and confirm the superior performance under the range of parameters tested. The correlations for heat transfer function (G) and roughness function (R) are also developed.
- 14 September 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 58 (4) , 531-559
Experimental study of thermal augmentation in solar air heater roughened with aligned gaps in V-rib roughness with staggered element geometry
- 14 September 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 58 (4) , 531-559