Toshitake Yakushiji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Toshitake Yakushiji has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Hiro Sato
Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Faculty of Medical and Pharmaceutical Sciences, Kumamoto University, Kumamoto, Japan
1 shared publicationHiroshi Mizuta
Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Faculty of Medical and Pharmaceutical Sciences, Kumamoto University, Kumamoto, Japan
1 shared publicationKiyoshi Oka
Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Faculty of Medical and Pharmaceutical Sciences, Kumamoto University, Kumamoto, Japan
1 shared publicationShigeta Yorimitsu
Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Faculty of Medical and Pharmaceutical Sciences, Kumamoto University, Kumamoto, Japan
1 shared publicationToru Fujimoto
Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Faculty of Medical and Pharmaceutical Sciences, Kumamoto University, Kumamoto, Japan
1 shared publicationYasuyuki Yamashita
Department of Diagnostic Radiology, Graduate School of Medical and Pharmaceutical Sciences, Kumamoto University, Kumamoto, Japan
1 shared publication
Latest Publications
- Open Access
- 20 March 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 29 (4) , 895-900
Characterization of chondroblastic osteosarcoma: Gadolinium‐enhanced versus diffusion‐weighted MR imaging
Purpose: To detect differences in magnetic resonance imaging (MRI) between chondroblastic osteosarcoma and the other types of osteosarcomas or chondrosarcomas using gadolinium‐enhanced versus diffusion‐weighted sequences.Materials and Methods: Contrast‐enhanced MRI and diffusion‐weighted imaging (DWI) were performed in five chondroblastic osteosarcoma (CO) cases, 17 other types of osteosarcomas (OS), and 18 chondrosarcomas (CS). DWI was obtained with a single‐shot echo‐planar imaging (EPI) sequence using a 1.5T MR imager. The apparent diffusion coefficients (ADCs) of the minimum and maximum values were also obtained. The contrast‐enhancement pattern was evaluated and minimum‐maximum ADC value of CO was compared with other types of OS and CS.Results: Both CO and CS showed a similar enhancement pattern; both showed septonodular and peripheral rim enhancement. The minimum ADC value of CO (1.24 ± 0.10 × 10−3mm2/sec) was significantly higher than that of other types of OS (0.84 ± 0.15 × 10−3mm2/sec) and was significantly lower than that of CS (1.64 ± 0.20 × 10−3mm2/sec). In addition, the maximum ADC value of CO (2.28 ± 0.20 × 10−3mm2/sec) was significantly higher than that of other types of OS (1.33 ± 0.26 × 10−3mm2/sec).Conclusion: DWI appears to be more useful for differentiating between chondroblastic osteosarcoma and chondrosarcoma or other types of osteosarcoma than Gd‐enhanced MRI. J. Magn. Reson. Imaging 2009;29:895–900.
- 20 March 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 29 (4) , 895-900
Open AccessCharacterization of chondroblastic osteosarcoma: Gadolinium‐enhanced versus diffusion‐weighted MR imaging
Purpose: To detect differences in magnetic resonance imaging (MRI) between chondroblastic osteosarcoma and the other types of osteosarcomas or chondrosarcomas using gadolinium‐enhanced versus diffusion‐weighted sequences.Materials and Methods: Contrast‐enhanced MRI and diffusion‐weighted imaging (DWI) were performed in five chondroblastic osteosarcoma (CO) cases, 17 other types of osteosarcomas (OS), and 18 chondrosarcomas (CS). DWI was obtained with a single‐shot echo‐planar imaging (EPI) sequence using a 1.5T MR imager. The apparent diffusion coefficients (ADCs) of the minimum and maximum values were also obtained. The contrast‐enhancement pattern was evaluated and minimum‐maximum ADC value of CO was compared with other types of OS and CS.Results: Both CO and CS showed a similar enhancement pattern; both showed septonodular and peripheral rim enhancement. The minimum ADC value of CO (1.24 ± 0.10 × 10−3mm2/sec) was significantly higher than that of other types of OS (0.84 ± 0.15 × 10−3mm2/sec) and was significantly lower than that of CS (1.64 ± 0.20 × 10−3mm2/sec). In addition, the maximum ADC value of CO (2.28 ± 0.20 × 10−3mm2/sec) was significantly higher than that of other types of OS (1.33 ± 0.26 × 10−3mm2/sec).Conclusion: DWI appears to be more useful for differentiating between chondroblastic osteosarcoma and chondrosarcoma or other types of osteosarcoma than Gd‐enhanced MRI. J. Magn. Reson. Imaging 2009;29:895–900.