Cumhur Tuncer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cumhur Tuncer has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Başak Arslan Avan
Faculty of Dentistry, Department of Orthodontics, Gazi University, Ankara, Turkey
4 shared publications - Burcu Baloş Tuncer
Department of Orthodontics, Faculty of Dentistry, University of Gazi, Ankara, Turkey
3 shared publications - Ertan Yildirim
Department of Chemistry, Science Faculty, Gazi University, 06500 Ankara, Turkey
2 shared publications - Onur Can Bodur
Faculty of Science, Department of Chemistry, Gazi University, Ankara, Turkey
2 shared publications - Akın Osanmaz
Department of Chemistry, Düzce University Graduate Education Institute, Düzce, Turkey
1 shared publication - Cagri Ulusoy
Faculty of Dentistry, Department of Orthodontics, Gazi University, Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1845
Comparison of the information of generative artificial intelligence large language models and professional guidelines regarding nutritional advice for orthodontic patients
To evaluate the credibility of large language models (LLMs) compared to American Association of Orthodontists (AAO) and British Orthodontic Society (BOS) g
- 26 November 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1845
Open AccessComparison of the information of generative artificial intelligence large language models and professional guidelines regarding nutritional advice for orthodontic patients
To evaluate the credibility of large language models (LLMs) compared to American Association of Orthodontists (AAO) and British Orthodontic Society (BOS) g
- Open Access
- 21 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-8
An in-vitro assessment of bisphenol a release from thermoplastic orthodontic appliances exposed to various beverages
Thermoplastic orthodontic appliances have been used as retention devices for years and gaining popularity as aligners, alternative to fixed orthodontic mechanics. This study aims to assess Bisphenol-A (BPA) release from thermoplastic orthodontic appliances exposed to different beverages. The appliances in this study were enrolled from aligners of Invisalign, ClearCorrect, and thermoplastic retention device, Essix ACE. Five different beverages (pure water, whole milk, coke, orange juice, filtered coffee) were determined and 5 glass tubes containing 10 ml of each beverage formed experiment groups. Appliance samples from each brand (with 0.50 ± 0.0082 g weight) were inserted in glass tubes and left in room temperature for 1 h. Later, samples were removed and Flow Injection Liquid Chromatography/Mass-Mass Spectrometry (FIA-LC/MS-MS) analysis was performed to evaluate BPA release. Five glass tubes for each beverage group, which did not contain any appliance, were also analyzed with the same technique to detect the possible pre-existing BPA levels in the liquids. FIA-LC/MS-MS analysis showed no measurable amount of BPA in pure water and any beverage group. BPA was also not detected in samples without appliances. BPA release was not detected from thermoplastic orthodontic appliances after 1 h of incubation in beverages. Within the limitations, different types of beverages were not found to affect BPA release from thermoplastic orthodontic materials. From a clinical perspective, further in-vivo studies will be useful with larger samples and longer term investigations.
- 21 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-8
Open AccessAn in-vitro assessment of bisphenol a release from thermoplastic orthodontic appliances exposed to various beverages
Thermoplastic orthodontic appliances have been used as retention devices for years and gaining popularity as aligners, alternative to fixed orthodontic mechanics. This study aims to assess Bisphenol-A (BPA) release from thermoplastic orthodontic appliances exposed to different beverages. The appliances in this study were enrolled from aligners of Invisalign, ClearCorrect, and thermoplastic retention device, Essix ACE. Five different beverages (pure water, whole milk, coke, orange juice, filtered coffee) were determined and 5 glass tubes containing 10 ml of each beverage formed experiment groups. Appliance samples from each brand (with 0.50 ± 0.0082 g weight) were inserted in glass tubes and left in room temperature for 1 h. Later, samples were removed and Flow Injection Liquid Chromatography/Mass-Mass Spectrometry (FIA-LC/MS-MS) analysis was performed to evaluate BPA release. Five glass tubes for each beverage group, which did not contain any appliance, were also analyzed with the same technique to detect the possible pre-existing BPA levels in the liquids. FIA-LC/MS-MS analysis showed no measurable amount of BPA in pure water and any beverage group. BPA was also not detected in samples without appliances. BPA release was not detected from thermoplastic orthodontic appliances after 1 h of incubation in beverages. Within the limitations, different types of beverages were not found to affect BPA release from thermoplastic orthodontic materials. From a clinical perspective, further in-vivo studies will be useful with larger samples and longer term investigations.
- 10 December 2024
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 126 (4) , 102195
Facemask application with fixed orthodontic appliances: 3-dimensional finite element stress analysis
- 10 December 2024
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 126 (4) , 102195
Facemask application with fixed orthodontic appliances: 3-dimensional finite element stress analysis
- 31 August 2022
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
Evaluation of Finite Element Analysis Studies Related to Maxillary Protraction with Facemask
İskeletsel Sınıf 3 maloklüzyonlar, özel tedavi planlamaları ve uzun süreli takipler gerektiren zorlu ortodontik problemlerdir. Maksillanın gelişim yetersizliğine bağlı olarak gelişen iskeletsel Sınıf 3 maloklüzyonların tedavisinde kullanılan yüz maskesi aygıtı çeşitli modifikasyonlarla çene ortopedisi alanında uzun yıllardır klinisyenler tarafından sıklıkla tercih edilmektedir. Yüz maskesi apareyinin ağız dışı kısmı, ağız içi ankraj üniteleriyle dişlere ve kemik yapılara bağlanır ve bu ünitelerin tasarımları, maksillaya uygulanan kuvvetin yönü, açısı, büyüklüğü gibi faktörler tedavi sonuçlarını etkileyebilen önemli parametrelerdir. Bu noktada bir mühendislik metodu olup diş hekimliği alanında da kullanılan sonlu elemanlar stres analizi yöntemi, apareylerin kraniyofasiyal bölgedeki olası etkilerini ve tedaviler sonucunda oluşabilecek stres ve yer değiştirme değerlerini saptayarak mühendisliği tıp ile birleştirebilmektedir. Herhangi bir yan etki oluşturmadan, uygulanabilecek en iyi maksiller protraksiyon protokolünü tespit etmek amacıyla yapılmış sonlu elemanlar stres analizi çalışmaları literatürde bulunmaktadır. Bu çalışmada ise, yüz maskesine bağlı maksiller protraksiyonun tedavisi ile ilgili daha önce yayınlanmış sonlu elemanlar analizi yöntemi çalışmaları derlenmiş ve değerlendirilmiştir.
- 31 August 2022
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
Evaluation of Finite Element Analysis Studies Related to Maxillary Protraction with Facemask
İskeletsel Sınıf 3 maloklüzyonlar, özel tedavi planlamaları ve uzun süreli takipler gerektiren zorlu ortodontik problemlerdir. Maksillanın gelişim yetersizliğine bağlı olarak gelişen iskeletsel Sınıf 3 maloklüzyonların tedavisinde kullanılan yüz maskesi aygıtı çeşitli modifikasyonlarla çene ortopedisi alanında uzun yıllardır klinisyenler tarafından sıklıkla tercih edilmektedir. Yüz maskesi apareyinin ağız dışı kısmı, ağız içi ankraj üniteleriyle dişlere ve kemik yapılara bağlanır ve bu ünitelerin tasarımları, maksillaya uygulanan kuvvetin yönü, açısı, büyüklüğü gibi faktörler tedavi sonuçlarını etkileyebilen önemli parametrelerdir. Bu noktada bir mühendislik metodu olup diş hekimliği alanında da kullanılan sonlu elemanlar stres analizi yöntemi, apareylerin kraniyofasiyal bölgedeki olası etkilerini ve tedaviler sonucunda oluşabilecek stres ve yer değiştirme değerlerini saptayarak mühendisliği tıp ile birleştirebilmektedir. Herhangi bir yan etki oluşturmadan, uygulanabilecek en iyi maksiller protraksiyon protokolünü tespit etmek amacıyla yapılmış sonlu elemanlar stres analizi çalışmaları literatürde bulunmaktadır. Bu çalışmada ise, yüz maskesine bağlı maksiller protraksiyonun tedavisi ile ilgili daha önce yayınlanmış sonlu elemanlar analizi yöntemi çalışmaları derlenmiş ve değerlendirilmiştir.
- 30 March 2022
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 35 (1) , 27-32
Effects of Tooth Brushing and MouthWashing on Leaching Bisphenol A Levels From an Orthodontic Adhesive: An In Vitro Study
Bisphenol A,orthodontic adhesives,leaching,tooth brushing,mouth washing
- 30 March 2022
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 35 (1) , 27-32
Effects of Tooth Brushing and MouthWashing on Leaching Bisphenol A Levels From an Orthodontic Adhesive: An In Vitro Study
Bisphenol A,orthodontic adhesives,leaching,tooth brushing,mouth washing