Cao Van Hiep
Cao Van Hiep has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Dinh Tien Hung
Military Institute of Chemical and Environmental Engineering (MICEE), Hanoi, Vietnam
2 shared publications Dinh Khang Pham
1 shared publicationDinh Tien Hung
Military Institute of Chemical and Environmental Engineering (MICEE), Hanoi, Vietnam
1 shared publicationKhanh Hung Nguyen
1 shared publication- Kien-Cuong Nguyen
Dalat Nuclear Research Institute, Dalat, Vietnam
1 shared publication Ngoc Anh Nguyen
1 shared publication
Latest Publications
- 11 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1203-1211
Nuclide Identification Algorithm for the Large-Size Plastic Detectors Based on Artificial Neural Network
This article proposes a multi-label classification model using an artificial neural network (ANN) to identify both an individual and a mixture of radionuclides in gamma spectra obtained from a $250\times 250\times 50$ -mm 3 EJ-200 plastic scintillation detector. This model is evaluated under the scenario applied to pedestrian radiation portal monitors (RPMs) to judge how well it works in practice. The simulated and measured gamma of 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ radioactive sources and background are used to generate the training dataset. Measurement data with varying source-to-detector distances, shielding thicknesses, and incidence angles are also taken into account. The experimental results show that the mean value of the accuracy can be achieved at about 98.8% and 94.9% for single- and multi-isotope identification, respectively. In addition, the model can well precisely recognize radionuclides in the gamma spectrum whose gain shift is up to 10%. The dependence of the true positive (TP) rate on the count quality factors of individual radionuclides, which was defined as the ratio between the net count rate and its associated uncertainty, is examined. The detection sensitivities, defined as the minimum count quality factor to obtain a TP rate of 95%, for 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ are 8.90, 11.86, 8.96, 8.21, 12.54, and 11.89, respectively. With such encouraging results, the proposed model should be a useful technique for radionuclide recognition.
- 11 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1203-1211
Nuclide Identification Algorithm for the Large-Size Plastic Detectors Based on Artificial Neural Network
This article proposes a multi-label classification model using an artificial neural network (ANN) to identify both an individual and a mixture of radionuclides in gamma spectra obtained from a $250\times 250\times 50$ -mm 3 EJ-200 plastic scintillation detector. This model is evaluated under the scenario applied to pedestrian radiation portal monitors (RPMs) to judge how well it works in practice. The simulated and measured gamma of 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ radioactive sources and background are used to generate the training dataset. Measurement data with varying source-to-detector distances, shielding thicknesses, and incidence angles are also taken into account. The experimental results show that the mean value of the accuracy can be achieved at about 98.8% and 94.9% for single- and multi-isotope identification, respectively. In addition, the model can well precisely recognize radionuclides in the gamma spectrum whose gain shift is up to 10%. The dependence of the true positive (TP) rate on the count quality factors of individual radionuclides, which was defined as the ratio between the net count rate and its associated uncertainty, is examined. The detection sensitivities, defined as the minimum count quality factor to obtain a TP rate of 95%, for 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ are 8.90, 11.86, 8.96, 8.21, 12.54, and 11.89, respectively. With such encouraging results, the proposed model should be a useful technique for radionuclide recognition.
- 11 November 2021
- Published by Academy of Military Science and Technology in Journal of Military Science and Technology
- No. 75A,p. 52-59
INVESTIGATING THE CHARACTERISTICS OF LARGE-VOLUME PVT SCINTILLATION DETECTORS IN THE RADIATION PORTAL MONITORS USING MONTE CARLO SIMULATIONS
This paper presents the characteristics determination process of the large-size Polyvinyl Toluene (PVT) scintillation detectors using MCNP5 simulation code. The energy spectra using a 137Cs calibration source, absolute efficiency in the energy range of 50 ÷ 3000 keV, and the angular response of the EJ-200 50×50×5 cm3 and 25×25×5cm3 are investigated. The simulated energy spectra are in good agreement with the experimental spectra. The results of determining the absolute efficiency show that the EJ-200 50×50×5 cm3 and 25×25×5cm3 plastic detectors have detection efficiencies of 16,3% and 9,2%, respectively, at 10cm source-to-detector distance, and down to 0,6% and 0,17% at 100 cm source-to-detector distance. The angular responses of the detectors show that the detection efficiency value reached ≥ 90% of the maximum value with the incident angle less than 5π/6. The results can be applied in the process of design optimization of plastic-based radiation portal monitors.
- 11 November 2021
- Published by Academy of Military Science and Technology in Journal of Military Science and Technology
- No. 75A,p. 52-59
INVESTIGATING THE CHARACTERISTICS OF LARGE-VOLUME PVT SCINTILLATION DETECTORS IN THE RADIATION PORTAL MONITORS USING MONTE CARLO SIMULATIONS
This paper presents the characteristics determination process of the large-size Polyvinyl Toluene (PVT) scintillation detectors using MCNP5 simulation code. The energy spectra using a 137Cs calibration source, absolute efficiency in the energy range of 50 ÷ 3000 keV, and the angular response of the EJ-200 50×50×5 cm3 and 25×25×5cm3 are investigated. The simulated energy spectra are in good agreement with the experimental spectra. The results of determining the absolute efficiency show that the EJ-200 50×50×5 cm3 and 25×25×5cm3 plastic detectors have detection efficiencies of 16,3% and 9,2%, respectively, at 10cm source-to-detector distance, and down to 0,6% and 0,17% at 100 cm source-to-detector distance. The angular responses of the detectors show that the detection efficiency value reached ≥ 90% of the maximum value with the incident angle less than 5π/6. The results can be applied in the process of design optimization of plastic-based radiation portal monitors.