Benedetta Spazzoli has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hip Hemi‐Resurfacing With 3D‐Printed Titanium Mini‐Prosthesis: A Case Report

    by D. M. Donati, B. Spazzoli, R. Laranga, D. Monopoli

    Background: Hip degeneration in young patients poses a significant clinical challenge, especially when the acetabulum remains intact. Total hip arthroplasty (THA) is often postponed in these patients due to concerns about implant longevity and multiple revisions. Joint‐preserving alternatives are therefore crucial. Case Presentation: We present the case of a 29‐year‐old male with progressive left hip pain and limited mobility. Imaging revealed a large subchondral cyst and structural alteration of the femoral head, while the acetabular cartilage appeared preserved. The patient′s preoperative Harris Hip Score (HHS) was 80, indicating poor joint function, and the preoperative WOMAC score of 20 reflected moderate pain and functional limitation. Considering the location and depth of the lesion, conservative and biological options were excluded. A custom‐made 3D‐printed hemi‐resurfacing mini‐prosthesis in titanium was designed based on CT imaging. The implant was inserted using a minimally invasive anterior approach and patient‐specific surgical guides. Results: After 3 years of follow‐up, the patient demonstrated excellent clinical and radiographic outcomes, with significant pain reduction, improved function (HHS improved to 94, and WOMAC improved to 4), and no signs of implant loosening or joint deterioration. Conclusion: This case highlights the potential of personalized, 3D‐printed mini‐prostheses as a viable bone‐preserving alternative to conventional joint replacement in young patients with focal femoral head pathology.

  • Blinded prediction of custom-made pelvic implant failure using patient-specific finite element modeling

    by Nicholas J. Dunbar, Yuhui Zhu, Ata Babazadeh-Naseri, John E. Akin, Benedetta Spazzoli, Claudio Belvedere, Davide M. Donati, Alberto Leardini, Benjamin J. Fregly

    Additively manufactured, custom-made implants used for reconstruction are a promising treatment following tumor resection. However, failure rates due to mechanical factors remain high when used in the pelvis for even state-of-the-art prosthesis designs. In a collaborative effort between a clinical and an engineering research team, this study evaluated whether patient-specific biomechanical modeling could predict, in a blinded fashion, the mode and location of a clinically-observed mechanical failure. Multiple failure criteria were considered including the risk of bone fracture due to overloading or stress shielding and prosthesis fracture due to overloading or fatigue. The blinded predictions indicated that the risk of fatigue failure in the pubic screws were eight times higher than the most critical ilium screw and two times higher than the most critical cancellous screw. Simulation of stress-shielding during walking matched evidence of osteolysis in the ilium and pubis. Incorporating patient-specific modeling into the custom implant design process may lead to improved durability.


  • Open Access

    3D Surgical Planning for Customized Devices in Orthopaedics: Applications in Massive Hip Reconstructions of Oncological Patients

    by Yazan Haidar, Claudio Belvedere, Benedetta Spazzoli, Davide Maria Donati, Alberto Leardini

    This study investigates the morphological impact of using three-dimensional (3D) printed custom implants in surgical hip reconstruction compared to the conventional bone graft and standard size implant methods. An amount of 16 patients at the Rizzoli Orthopaedic Institute who underwent hip reconstruction surgery for tumors involving the P2 pelvis region were selected using stratified sampling. Half of them were randomly selected to receive 3D-printed implants, and the other half were selected to receive standard implants with bone grafts. Six months post-surgery, computed tomography (CT) scans were used to identify the hip joint center of rotation and to measure greater the trochanter offset and acetabular inclination angle. These CT scans were also used to construct a 3D model of the pelvis for 3D measurements. The results show no significant differences in accuracy, using Student’s t-test and Mann–Whitney U-test (p-value > 0.05), between the two methods for reconstructing the hip joint center of rotation or greater trochanter offset. However, 3D-printed implants showed statistically significant greater precision, using Student’s t-test (p-value < 0.05), in reconstructing the acetabular inclination angle compared to the conventional bone graft and standard-sized off-the-shelf implants. This superior precision reduces the risk of impingement of the femur implant neck with the acetabulum implant cup, which directly relates to improved implant survivorship. These findings support the continued exploration of 3D printing technology for personalized orthopedic solutions.


  • Open Access

    Current Concepts in the Resection of Bone Tumors Using a Patient-Specific Three-Dimensional Printed Cutting Guide

    by Hisaki Aiba, Benedetta Spazzoli, Shinji Tsukamoto, Andreas F. Mavrogenis, Tomas Hermann, Hiroaki Kimura, Hideki Murakami, Davide Maria Donati, Costantino Errani

    Orthopedic oncology has begun to use three-dimensional-printing technology, which is expected to improve the accuracy of osteotomies, ensure a safe margin, and facilitate precise surgery. However, several difficulties should be considered. Cadaver and clinical studies have reported more accurate osteotomies for bone-tumor resection using patient-specific cutting guides, especially in challenging areas such as the sacrum and pelvis, compared to manual osteotomies. Patient-specific cutting guides can help surgeons achieve resection with negative margins and reduce blood loss and operating time. Furthermore, this patient-specific cutting guide could be combined with more precise reconstruction using patient-specific implants or massive bone allografts. This review provides an overview of the basic technologies used in the production of patient-specific cutting guides and discusses their current status, advantages, and limitations. Moreover, we summarize cadaveric and clinical studies on the use of these guides in orthopedic oncology.


  • Open Access

    Periacetabular Tumour Resection under Anterosuperior Iliac Spine Allows Better Alloprosthetic Reconstruction than Above: Bone Contact Matters

    by Alessandro Bruschi, Luca Cevolani, Benedetta Spazzoli, Marco Focaccia, Stefano Pasini, Tommaso Frisoni, Davide Maria Donati

    Background: Periacetabular resections are more affected by late complications than other pelvic resections. Reconstruction using bone allograft is considered a suitable solution. However, it is still not clear how the bone-allograft contact surface impacts on mechanical and functional outcome. Materials and methods: This paper presents the results of a retrospective analysis of 33 patients with resection of the entire acetabulum and reconstruction with an allograft-prosthetic composite for the period 1999 to 2010. Patients were divided in two groups, based on type of resection. In Group 1. patients had resections under anterosuperior iliac spine allowing the highest bone-allograft surface contact in reconstruction, while in Group 2 patients had resections over it. Results: Mechanical survival of the implant and Musculoskeletal Tumor Society functional score were calculated. Impact of age and artificial ligament were investigated as well. Patients in Group 1 had 38% mechanical failure rate of the implant while patients in Group 2 had 88%. Average functional score was higher in Group 1 compared with patients in Group 2. An artificial ligament was shown to have non-significant impact on survival of the reconstruction in Group 1, while significantly improving survival of reconstruction in Group 2. Conclusion: Bone-allograft contact matters: resection under anterosuperior iliac spine allows better mechanical survival and offers better reconstruction functional scores.


  • Open Access

    miR-214-3p Is Commonly Downregulated by EWS-FLI1 and by CD99 and Its Restoration Limits Ewing Sarcoma Aggressiveness

    by Alessandra De Feo, Laura Pazzaglia, Lisa Ciuffarin, Fabio Mangiagli, Michela Pasello, Elisa Simonetti, Evelin Pellegrini, Cristina Ferrari, Giuseppe Bianchi, Benedetta Spazzoli, et al.

    Ewing’s sarcoma (EWS), an aggressive pediatric bone and soft-tissue sarcoma, has a very stable genome with very few genetic alterations. Unlike in most cancers, the progression of EWS appears to depend on epigenetic alterations. EWS–FLI1 and CD99, the two hallmarks of EWS, are reported to severely impact the malignancy of EWS cells, at least partly by regulating the expression of several types of non-coding RNAs. Here, we identify miR-214-3p as a common mediator of either EWS-FLI1 or CD99 by in silico analysis. MiR-214-3p expression was lower in EWS cells and in clinical samples than in bone marrow mesenchymal stem cells, and this miRNA was barely expressed in metastatic lesions. Silencing of EWS-FLI1 or CD99 restored the expression of miR-214-3p, leading to a reduced cell growth and migration. Mechanistically, miR-214-3p restoration inhibits the expression of the high-mobility group AT-hook 1 (HMGA1) protein, a validated target of miR-214-3p and a major regulator of the transcriptional machinery. The decrease in HMGA1 expression reduced the growth and the migration of EWS cells. Taken together, our results support that the miR-214-3p is constitutively repressed by both EWS-FLI1 and CD99 because it acts as an oncosuppressor limiting the dissemination of EWS cells.


  • Custom Reconstruction Around the Knee

    by Davide Maria Donati, Tommaso Frisoni, Benedetta Spazzoli

  • Open Access

    A Pelvic Reconstruction Procedure for Custom-Made Prosthesis Design of Bone Tumor Surgical Treatments

    by Gilda Durastanti, Claudio Belvedere, Miriana Ruggeri, Davide Maria Donati, Benedetta Spazzoli, Alberto Leardini

    In orthopaedic oncology, limb salvage procedures are becoming more frequent thanks to recent major improvements in medical imaging, biomechanical modelling and additive manufacturing. For the pelvis, surgical reconstruction with metal implants after tumor resection remains challenging, because of the complex anatomical structures involved. The aim of the present work is to define a consistent overall procedure to guide surgeons and bioengineers for proper implant design. All relevant steps from medical imaging to an accurate 3D anatomical-based model are here reported. In detail, the anatomical 3D models include bone shapes from CT on the entire pelvic bone, i.e., including both affected and unaffected sides, and position and extension of the tumor and soft tissues from MRI on the affected side. These models are then registered in space, and an initial shape of the personalized implant for the affected side can be properly designed and dimensioned based on the information from the unaffected side. This reported procedure can be fundamental also for virtual pre-surgical planning, and the design of patient-specific cutting guides, which would result is a safe margin for tumor cut. The entire procedure is here shown by describing the results in a single real case.


  • Open Access

    Computer Assisted Surgery and 3D Printing in Orthopaedic Oncology: A Lesson Learned by Cranio-Maxillo-Facial Surgery

    by Giuseppe Bianchi, Tommaso Frisoni, Benedetta Spazzoli, Alessandra Lucchese, Davide Donati

    Primary bone sarcomas are rare tumors and surgical resection in combination with chemo and radiation therapy is the mainstay of treatment. Some specific anatomical sites still represent a reconstructive challenge due to their complex three-dimensional anatomy. In recent years, patient specific instruments along with 3D printing technology has come to represent innovative techniques in orthopaedic oncology. We retrospectively reviewed 23 patients affected by primary bone sarcoma treated with patient-specific instruments and 3D printing custom made prostheses. At follow up after approximately two years, the infection rate was 26%, mechanical complication rate 13%, and local recurrence rate 13% (with a five-years implant survival rate of 74%). Based on our experience, patient-specific instruments and 3D custom-made prostheses represents a reliable and safe technique for improving the accuracy of resection of primary bone tumour, with a particular use in pelvic surgery ameliorating functional results.